Refine
Year of publication
Document Type
- Article (46)
- Conference Proceeding (6)
- Review (2)
Has Fulltext
- yes (54)
Is part of the Bibliography
- no (54)
Keywords
- ELISA (3)
- Antikörpertest (2)
- HCMV (2)
- IFT (2)
- Impfraten (2)
- Medizinstudenten (2)
- Myokarditis (2)
- Nachweismethoden (2)
- PCR (2)
- Perikarditis (2)
- Sensitivity and Specificity (2)
- Sensitivität und Spezifität (2)
- Serodiagnosis (2)
- Vaccination (2)
- antibody test (2)
- blood borne infection (2)
- blutübertragbare Infektionskrankheiten (2)
- medical students (2)
- myocarditis (2)
- nutlin-3 (2)
- oncomodulation (2)
- p53 (2)
- pericarditis (2)
- test methods (2)
- vaccine uptake rates (2)
- Adhesion (1)
- Angiogenesis (1)
- Antibodies (1)
- Antigen- und Nukleinsäurenachweis (1)
- Antigennachweis (1)
- Atherosklerose (1)
- Bovine Spongiforme Enzephalopathie (BSE) (1)
- Bovine spongiform, encephalopathy (BSE) (1)
- CMV isolation (1)
- CMV risk groups are: pregnancy - blood transfusion - organ transplantation - prostitutes (1)
- CMV-Isolierung (1)
- Cats (1)
- Chlamydia-Infections/urine (1)
- Chlamydien (1)
- Chlamydieninfektionen/Urin (1)
- Chronisch aktive/Diagnostik (1)
- Cytomegalie (1)
- Cytomegalie-Virus (1)
- Cytomegalovirus (1)
- Cytomegalovirus Infection (1)
- DNA, Virale/Blut (1)
- Diagnostics (1)
- Ehrlich (1)
- Elimination (1)
- Enzyme-linked Immunosorbent Assay (1)
- Enzyme-linked immunoassays (1)
- Epidemie (1)
- Epidemiologie (1)
- Eradication (1)
- Ergebnisquantifizierung (1)
- Erregernachweis (1)
- Frankfurt (1)
- Frankfurt <Main> / Paul-Ehrlich-Institut (1)
- G207 (1)
- Genamplifikation (1)
- Gene-Amplification (1)
- Germany (1)
- H1N1 (1)
- HBV (1)
- HCV (1)
- HHV-8 (1)
- HIV (1)
- HIV-1 Genotypisierung (1)
- HIV-1 genotyping (1)
- HIV-Infektionen (1)
- HSV type specific antibodies (1)
- HSV-1 (1)
- HSV-typenspezifische Antikörper (1)
- Hepatitis (1)
- Hepatitis B (1)
- Hepatitis B Antibodies/serum (1)
- Hepatitis B Core-Antigene/Immunologie (1)
- Hepatitis B-Antikörper/Serum (1)
- Hepatitis B-Core-Antigens-immunology (1)
- Hepatitis C (1)
- Hepatitis C; DNA (1)
- Hepatitis G virus (1)
- Hepatitis G-Virus (1)
- Hepatitis, Chronic Active/diagnosis (1)
- Herd immunity (1)
- Herpe-Viren (1)
- Herpes virus (1)
- HlV-Infections (1)
- Hyposensibilisierung (1)
- Ig (sub)class-specific antibody determination (1)
- Ig- (sub)klassen-spezifische Antikörperbestimmung (1)
- IgM/Immunologie (1)
- IgM/immunology (1)
- Immunenzymtechniken (1)
- Immunitätsbeurteilung (1)
- Immunoenzyme Techniques (1)
- Influenza (1)
- Interferon alpha (1)
- Isolierung (1)
- KSHV epidemiology (1)
- KSHV, Epidemiologie (1)
- Koronare Herzkrankheit (1)
- Labordiagnose (1)
- Labordiagnostik (1)
- Lack of immunity (1)
- MDM2 (1)
- Macrophages (1)
- Measles (1)
- Monoclonal antibodies (1)
- N-myc (1)
- NCAM (1)
- Pandemie (1)
- Paul (1)
- Plasmapools (1)
- Plasmapräparate (1)
- Plausibilität (1)
- Poliomyelitis (1)
- Polymerase Chain Reaction (1)
- Polymerase Kettenreaktion (PCR) (1)
- Polymerasekettenreaktion (1)
- Quantitative Antikörpermessung (1)
- RITA (1)
- RNA, Virale/ Blut (1)
- ReagentKits, -Diagnostic (1)
- Reagenzkits, Diagnostische (1)
- Resistenzprüfung (1)
- Resistenztestung (1)
- Respiratorische Infekte (1)
- Respiratory infections (1)
- Ringversuch (1)
- Risikogruppen sind: Schwangerschaft - Bluttransfusion - Organtransplantation - Prostituierte (1)
- SARS (1)
- SARS coronavirus (1)
- Screening-ELISA (1)
- Serodiagnose (1)
- Serodiagnostik (1)
- Seroepidemiology (1)
- Speziesbarriere (1)
- Störfaktoren in der serologischen Diagnostik (1)
- Surveillance (1)
- Therapiemonitoring (1)
- Therapy (1)
- Transplantation/Immunologie (1)
- Transplantation/immunology (1)
- TruGene (1)
- Urethra/Mikrobiologie (1)
- Urethra/microbiology (1)
- Vakzination (1)
- Variation (Genetics) (1)
- Variation (Genetik) (1)
- Viral Load (1)
- Viral Matrix Proteins (1)
- Viral/blood (1)
- Viral/blood; RNA (1)
- Virale Matrixproteine (1)
- Viremia-diagnosis (1)
- ViroSeq (1)
- Virus (genom) nachweis (1)
- Virusisolierung (1)
- Viruslast (1)
- Virusnachweis (1)
- Viruspneumonien (1)
- Virussicherheit (1)
- Vorbeugemaßnahmen (1)
- Western blot (1)
- Zellkultur (1)
- Zytomegalievirus-IgG-Antikörper (1)
- antigen detection (1)
- atherosclerosis (1)
- avian flu (1)
- aviäre Influenza (1)
- cancer cell malignancy (1)
- cell culture (1)
- chemoresistance (1)
- chemotherapy (1)
- chlamydia (1)
- clinical communication (1)
- coronary heart disease (1)
- cytomegalovirus-specific IgG (1)
- demonstration of the infectious agent (1)
- detection of virus antigen and nucleic acid (1)
- disturbing factors in serodiagnosis (1)
- drug resistance (1)
- enteral transmission (1)
- enterale Übertragung (1)
- epidemic (1)
- epidemiology (1)
- human cytomegalovirus (1)
- human prion diseases (1)
- human rhabdomyosarcoma (1)
- hyposensitization (1)
- immune assessment (1)
- influenza (1)
- integrins (1)
- internal/external controls (1)
- interne/externe Kontrollen (1)
- isolation (1)
- laboratory diagnosis (1)
- laboratory diagnostic (1)
- long-term infection (1)
- menschliche Prionenerkrarikungen (1)
- microbiologic agents (1)
- mikrobiologische Erreger (Bakterien, Pilze, Protozoen) (1)
- neuroblastoma (1)
- p53 activator (1)
- p73 (1)
- pandemic (1)
- plasma pools and products (1)
- polymerase chain reaction (PCR) (1)
- precautions (1)
- proficiency testing (1)
- prostate carcinoma cells (1)
- quantitative determination of viral antibodies (1)
- radiation (1)
- resistance analysis (1)
- resistance testing (1)
- respiratorische Infektion (1)
- respiratory infection (1)
- respiratory infections (1)
- result quantitation; (1)
- ribonucleotide reductase (1)
- screening ELISA (1)
- species barrier (1)
- therapy monitoring (1)
- tumor dissemination (1)
- vaccination (1)
- viral contamination (1)
- virologic agents (1)
- virologische Erreger (1)
- virus (genome) detection. (1)
- virus detection (1)
- virus isolation (1)
- virus pneumonia (1)
Institute
- Medizin (53)
- Biowissenschaften (1)
- Erziehungswissenschaften (1)
Die Zytomegafie ist eine meist lebenslänglich latent bleibende vertikale und horizontale Herpesvirusinfektion mit gelegentlich schweren Krankheitsbildern, auch als Ursache oder Folge von Immunstörungen. Dem Virus wird ein onkogenes Potential zugeschrieben, zuletzt diskutiert bei AIDS und M. Kaposi. Für die Labordiagnose verfügen wir über die Mikroskopie (Zellkerneinschlüsse) und Elektronenmikroskopie, Nachweis der Virusinfektiosität auf Zellkulturen, DNA- und Polypeptidanalyse zur Virusstammidentifikation, direkte DNA- und Antigennachweise aus Patientenmaterial, immunhistologische Methoden (z.B. Immunperoxydase- Technik). Die Untersuchung der Immunzellen erfolgt bei der Zytomegalie quantitativ (T-ZellQuotient) und qualitativ (Lymphozytenstimulierung, neuerdings auch mit Vollblut). Am leichtesten gelingt die Labordiagnose serologisch, d.h. über den Antikörpernachweis. Dafür sind eine Vielzahl „liquid" und „solid phase"-Assays entwickelt worden. Am meisten haben sich heute neben der KB R (und P H A) Immunofluororeszenz und ELISA durchgesetzt, wobei einerseits unterschiedliche Antigene („early", „late antigens") und Antigenpräparationen (z. B. Viruskapsid, -envelope) zum Einsatz kommen, andererseits verschiedene Ig- Klassen und -Subklassen getestet werden, um die primäre und sekundäre Zytomegalie zu diagnostizieren und zu differenzieren. Speziell für den Ig M -Nachweis wurden viele Testmodifikationen etabliert; Rheumafaktorinterferenz und IgG-Kompetition lassen sich am besten durch IgG-Präzipitation ausschalten. Die neuen Methoden haben nicht nur die Aufklärung vieler interessanter Krankheitsfälle, sondern auch exakte epidemiologische Studien bei Risikogruppen ermöglicht (Blutspender: 47[0], schwangere Frauen 56[13], Patienten mit Hämophilie: 69[0], nach NTPL: 90[24], nach Herz-OP: 87[1], Prostituierte: 90[1]% CMV-IgG[(IgM)- Antikörperträger].
Herpes simplex virus type 2 (HSV-2) is the main cause of herpes genitalis, a recurrent sexually transmitted disease. By the use of routine Serologie methods (complement fixation test, enzyme immunoassay), virus carriers are difficult to identify because of strong antibody cross reactions with antigens of HSV-1 which is ubiquitously spread throughout the population. We introduce a microtechnique Western blot system loaded with HSV-1 and HSV-2 type-specific and common antigens on separated nitrocellulose strips. By the simultaneous evaluation of Immunologie reactions with both strips, the occurrence of HSV-2 specific antibodies can be sensitively detected in serum specimens containing antibodies to HSV-1. A total of 158 serum specimens were analyzed and the results obtained by Western blot were compared to those of a screening ELISA and virus isolation performed with smears of herpes lesions.
An agreement of 97.9 % was assessed between Western blot and virus isolation to detect an HSV-1 and HSV-2 infection. Less specific serologic results were produced by the screening ELISA on HSV-2 antibodies which correlated in 85.4 % (41/48) with virus isolation and typing. Concerning HSV-2 antibody testing, Western blot and ELISA showed an overall agreement in 89.8 % of the sera investigated.
As shown by our data, the HSV type specific Western blot proved to be a specific, reproducible and standardized technique. It can be utilized for both sero-epidemiological surveys and determination of the HSV immune status.
Trotz der Spenderauswahl, des serologischen Screenings der Blutspenden auf antiHIV-1, anti-HIV-2, anti-HCV und HBsAg, Inaktivierungs- und Eliminierungsverfahren bleibt ein Restrisiko für hämatogen übertragbare Viren bei Plasmapools und den daraus hergestellten Präparaten. Als zusätzliche Screeningmethode zur Erhöhung der Virussicherheit wird inzwischen die Testung der Einzelspende bzw. von Minipools auf HCV-RNA verlangt. In der vorliegenden Arbeit wurden 142 HBsAg, anti-HCV- und anti-HIV-11-2 negative Plasmapools, sowie Plasmapräparate (Immunglobulinpräparat und F IX Präparat), welche zum Teil aus für HGV-RNA PCR-positiven Ausgangspools hergestellt worden waren, mittels PCR auf das Vorhandensein von HGV-Nukleinsäure untersucht. Alle untersuchten Pools bzw. Plasmapräparate stammten von Spenden zwischen 1994 und 1996, also vor der Einführung der genannten Pflichttestung auf HCV-RNA. HGV-RNA wurde in 117 der 142 Plasmapools (82,4%) amplifiziert. Allerdings war HGV-RNA nur in einer (6,3%) von 16 IgG-Chargen aus für HGV-Nukleinsäure positiven Kryoüberständen nachweisbar. In 2 (6,5%) von 31 unselektierten Immunglobulinpräparaten war eine HGV- Kontamination vorhanden. Eine routinemäßige Anwendung der PCR ist zur Zeit aus technischen sowie Kosten-Nutzen-Überlegungen für HGV nicht zu empfehlen, solange die klinische Relevanz nicht gesichert ist. Die Ergebnisse unterstreichen die Wichtigkeit der im Herstellungsprozeß integrierten Viruseliminierungsverfahren, denn bei der vorliegenden Studie konnte nur in einem geringen Anteil der Endproduktchargen HGV-Nukleinsäure nachgewiesen werden.
603 Seren aus dem Raum Frankfurt am Main wurden in 12 verschiedenen Einzelkollektiven mit einem "in house" IFT mit latenten Antigenen und einem rekombinanten Prototyp ELISA mit dem LANA und K8.1-Protein auf Antikörper gegen das Humane Herpesvirus Typ 8 (HHV-8) ± auch bekannt als Kaposi-Sarkom-assoziiertes Herpesvirus (KSHV) ±getestet. Untersucht wurden (Risiko)gruppen wie HIV-seropositive Männer und Frauen, HIV-seronegative homosexuelle bzw. bisexuelle Männer, Patienten mit Kaposi-Sarkom, Transplantationspatienten und Kinder mit Hämophilie. Zur Abschätzung von Kreuzreaktionenund anderen Störungen der Testsysteme wurden Patienten mit akuten bzw. abgelaufenen EBV-Infektionen,HHV-6-seropositive Patienten, Rheumafaktor-positive Probanden und Frauen mit primärer biliärer Zirrhose(PBC) untersucht. Dreiundfünfzig diskrepante Probenwurden mit kommerziellen IFTs mit latenten bzw. lyti-schen Antigenen nachgetestet.Hohe HHV-8-SeropraÈvalenzen wurden bei HIV-Infizierten ohne (15,7 % bei Frauen, 23,3 % bei Männern)und insbesondere mit Kaposi-Sarkomen (100 %) gefunden. Eine geschlechtsabhängige Verteilung der Seroprävalenz bei den HIV-seropositiven Patienten wurde nicht festgestellt. Bei Blutspendern wurde eine HHV-8-Durchseuchung von 3 % (im ¹in-house-IFTª), bei Hämophilen von 0 % und bei Transplantationspatienten von 9,1 % ermittelt. Kreuzreaktionen mit Antikörpern gegen andere Herpesviren wie EBV und HHV-6 schienen die Tests nicht zu beeinflussen, während sich tendenziell eine erhöhte Anzahl reaktiver Proben bei Patienten mit Autoimmunantikörpern (Rheumafaktor-positive Patienten und Patientinnen mit PBC) zeigte. Insgesamt stimmten die Ergebnisse des rekombinanten ELISA mit denen des "in house"-IFT im Gesamtkollektiv gut überein. Unterschiedliche Ergebnisse fanden sich in den Einzelkollektiven, insbesondere bei Rheumafaktor-positiven Patienten und solchen mit PBC.
[Abstract] Occurrence of hepatitis B virus (HBV) reactivation following kidney transplantation
(2004)
Der Nachweis von Chlamydia trachomatis Genomsequenzen ist seit einigen Jahren mit Hilfe kommerzieller Testkits, welche auf dem Prinzip der Polymerase-Ketten-Reaktion (PCR) oder Ligase-Kettenreaktion (LCR) beruhen, möglich. Vor kurzem wurde ein neues Verfahren, die Transcription Mediated Amplification (TMA), etabliert. In der vorliegenden Studie wurden drei Nukleinsäure Amplifikations-Techniken, die PCR, die LCR und die TMA für den Nachweis von Chlamydia trachomatis aus Urinproben miteinander bezüglich Sensitivität und Spezifität verglichen und einem Enzym-Immuno-Assay (EIA) zum C. trachomatis-Antigen-Nachweis aus endozervikalen Abstrichen gegenübergestellt. PCR, LCR und TMA zeigten eine vergleichbare Sensitivität und Spezifität. Diskrepante Ergebnisse ergaben sich im Vergleich mit dem C. trachomatis-Antigen-Nachweis. In 22 Abstrichen war Chlamydien-Antigen nachzuweisen. Nur bei 12 bzw. 11 der untersuchten Prostituierten konnten bei positivem zervikalen Abstrich Chlamydia trachomatis Genomsequenzen im Urin nachgewiesen werden. Bei 5 bzw. 4 Frauen wurde bei negativem Abstrichbefund C. trachomatis DNA bzw. RNA im Urin gefunden. Um bei Frauen eine hohe diagnostische Sensitivität zu erreichen, .sollten Urin und endozervikale Abstriche untersucht werden, da C. trachomatis nicht immer in beiden Probematerialien nachweisbar ist.
Das erstmals Ende 2002 im Süden Chinas aufgetretene schwere akute respiratorische Syndrom (SARS) führte bis zum August 2003 zu insgesamt über 8000 Erkrankungen und über 700 Todesfällen. Eine von der Weltgesundheitsorganisation (WHO) ins Leben gerufene Kooperation verschiedener Laboratorien weltweit ermöglichte innerhalb von nur vier Wochen die Identifizierung des kausalen Agens, eines bislang unbekannten Coronavirus (vorläufig bezeichnet als SARS-assoziiertes Coronavirus oder SARS-CoV), welches die Koch’schen Postulate erfüllt. Der Erreger lässt sich (unter Hochsicherheitsbedingungen) gut in Zellkulturen vermehren, was weitere Studien zur Stabilität sowie die Entwicklung von antiviral wirksamen Substanzen und Impfstoffen erleichtert.
Obwohl schon rasch diagnostische Labortests, insbesondere zum Nachweis der viralen Nukleinsäure und virusspezifischer Antikörper, zur Verfügung standen, basiert die Falldefinition von SARS weiterhin auf klinisch-epidemiologischen Kriterien. In Hinblick auf die Gefahr eines (saisonalen) Wiederauftretens der Infektion müssen die verfügbaren Labormethoden dringend überprüft und weiter verbessert werden.
SARS ist ein gutes Beispiel dafür, wie schnell sich eine Infektionskrankheit über den internationalen Reiseverkehr ausbreiten kann, aber auch dafür, wie wichtig in einem solchen Falle eine gut koordinierte internationale Kooperation ist; durch Einsatz neuester, aber auch bewährter konventioneller Labormethoden und ständigen Austausch aktueller (Zwischen-)Ergebnisse sowie von Patientenproben und Reagenzien führte eine bisher einmalige Zusammenarbeit schnell zu einem Durchbruch. Dies lässt auf ähnliche Fortschritte beim Kampf gegen weitere neuartige Infektionserreger hoffen.
Die HIV-1-Resistenztestung wird ein immer bedeutenderer Bestandteil des Monitorings der antiretroviralen Therapie und erfolgt in der Regel mittels Genotypisierung. Zur Zeit sind zwei Systeme kommerziell erhältlich und obwohl diese technisch nicht zu den einfach durchführbaren Methoden gehören, haben sie doch einen hohen Grad an Qualität erreicht. Modifikationen der Standardprotokolle sind für bestimmte Fragestellungen durchaus von Vorteil. Obwohl beide Systeme auf Entscheidungsregeln basierende Resistenz-Reports beinhalten, braucht es das zusätzliche Wissen und die Erfahrung des Anwenders, um die detektierten Mutationsmuster in klinisch brauchbare Resultate überführen zu können. Beide der hier detailliert beschriebenen Systeme haben ihre Vor- und Nachteile. Die Entscheidung für das eine oder andere System muss aufgrund der individuellen Bedürfnisse getroffen werden. Microarray-Systemen könnte der Markt der Zukunft gehören.