Refine
Document Type
- Article (12)
Has Fulltext
- yes (12)
Is part of the Bibliography
- no (12)
Keywords
- DMEK (5)
- Fuchs endothelial dystrophy (2)
- Scheimpflug imaging (2)
- Visual quality (2)
- corneal edema (2)
- corneal transplantation (2)
- Augenerkrankungen (1)
- Autoimmune response (1)
- Corneal tomography (1)
- DSAEK (1)
- Education (1)
- Eye diseases (1)
- EyesiNet (1)
- Lehre (1)
- Netzhaut (1)
- Ocular tuberculosis (1)
- Phlyctenule (1)
- Pseudophakia (1)
- Refractive changes (1)
- Retina (1)
- Scrofulous keratitis (1)
- Student (1)
- cornea donor (1)
- hepatitis B virus (1)
- hepatitis C virus (1)
- human immunodeficiency virus (1)
- postmortem blood samples (1)
- repeat DMEK (1)
- serologic screening (1)
Institute
- Medizin (12)
Purpose: To evaluate the potential impact of rebubbling on the anterior segment parameters and refractive outcomes in patients with graft detachment following uneventful DMEK for Fuchs endothelial dystrophy (FED).
Methods: Retrospective institutional cohort study of comparing 34 eyes of 31 patients with rebubbling for graft detachment following Descemet membrane endothelial keratoplasty (DMEK) to 33 eyes of 28 patients with uneventful DMEK. Main outcome parameters were various corneal parameters obtained by Scheimpflug imaging, refractive outcome, corrected distance visual acuity (CDVA), and endothelial cell density (ECD).
Results: Anterior and posterior corneal astigmatism, corneal densitometry, central corneal thickness, and anterior chamber depth and volume showed no significant differences. Preoperative distribution of astigmatism axis orientations showed a high proportion of anterior corneal with-the-rule astigmatism (71%) in eyes requiring rebubbling. Mean postoperative cylinder in the rebubbling group (1.21 ± 0.85 D) was significantly higher compared to the controls (p = 0.04), while differences in spherical equivalent (SE) were insignificant (p = 0.24). Postoperative CDVA was 0.11 ± 0.11 in the control group compared to 0.21 ± 0.17 in the rebubbling group (p = 0.03). Eyes with subsequent rebubbling demonstrated a significantly higher endothelial cell loss (56% versus 37%) (p < 0.001).
Conclusion: Apart from higher cylinder values, refractive outcome and corneal parameters assessed by Scheimpflug imaging were comparable in eyes with rebubbling and controls. However, a reduced visual acuity and an increased endothelial cell loss should be taken into consideration prior to rebubbling especially in eyes with circumscribed graft detachment.
Purpose: To report a case of autoimmune keratitis in a patient with mycobacterium tuberculosis (MBT).
Methods: An 84-year-old male with pulmonary tuberculosis (TB) was admitted with chronic, non-healing bilateral ulcerations of the inferior peripheral cornea associated with stromal and subconjunctival nodules.
Results: Clinical examination revealed circumscribed peripheral corneal ulceration with whitish nodules in adjacent stromal and subconjunctival tissue. Microbiological cultures of the corneal tissue were negative for MBT and other microbial pathogens; however, enzyme-linked immunosorbent assay (ELISA) of blood and corneal samples showed significantly elevated levels of IgM and IgA against MBT. In addition to systemic anti-tuberculosis therapy, the patient was treated topically with Polyspectran® eye drops, Dexamethasone eye drops, and Bepanthen® ointment, for 2 weeks. Both eyes showed dramatic improvement after 2 weeks.
Conclusion: The present report demonstrates that MBT is able to initiate delayed autoimmune response within the corneal tissue during an intensive phase of anti-tuberculosis treatment.
Hintergrund: Die Ophthalmoskopie ist Bestandteil des medizinischen Curriculums, jedoch das Vermitteln der Inhalte oft unbefriedigend, da ein systematisches Lernen von Pathologien und deren Behandlungen dadurch erschwert ist, dass oftmals das passende Patientengut nicht zur Verfügung steht und dadurch gesunde Studenten einander untersuchen müssen. Aus diesem Grund haben wir eine Online-Plattform entwickelt, die in Kombination mit simulationsgestütztem Training sowohl das eigenständige als auch das angeleitete Lernen von Untersuchungsmethoden und Pathologien ermöglicht.
Ziel der Arbeit: Ziel der vorliegenden Arbeit war, ein Format für die Verbesserung der Lehre der direkten und indirekten Ophthalmoskopie im Studierendenunterricht zu evaluieren. Dabei wurden praktische Übungen an Virtual-Reality-basierten Simulatoren mit neu entwickelten und an den Lehrkatalog angepassten theoretischen Inhalten in der Online-Plattform EyesiNet verschränkt.
Material und Methoden: Die Studierenden bearbeiteten am ersten sowie am letzten Praktikumstag zufällig ausgewählte Fälle, die ihnen von den Eyesi Direct- und Eyesi Indirect-Simulatoren präsentiert wurden. Zwischen diesen beiden Einheiten konnten sie sich auf freiwilliger Basis mit den theoretischen Grundlagen typischer ophthalmologischer Krankheitsbilder im EyesiNet beschäftigen.
Ergebnisse: Eyesi Direct: Die Bewertung des Simulators ergab am ersten Praktikumstag für beide Gruppen keinen signifikant unterschiedlichen Wissensstand (p = 0,29). In der Gruppe OHNE Training (n = 54) ergab sich am letzten Praktikumstag mit p = 0,02 eine signifikante Verbesserung dieser Bewertung, jedoch mit einer geringen Effektgröße von 0,1. In der Gruppe MIT Training (n = 32) konnte mit p = 0,0004 eine hoch signifikante Verbesserung mit einer Effektgröße von 0,3 nach Rosenthal festgestellt werden. Eyesi Indirect: Die simulatorgestützte Bewertung ergab am ersten Praktikumstag keinen signifikanten Unterschied im Wissensstand der beiden Gruppen (p = 0,1). Nach dem Training schnitten zwar beide Gruppen etwas besser ab, jedoch ohne signifikanten Unterschied (OHNE Training p = 0,41/MIT Training p = 0,17).
Diskussion: Die Online-Plattform EyesiNet unterstützt beim Erlernen der wichtigsten Erkrankungsbilder. Lerninhalte werden reproduzierbar und auf für alle Lernenden standardisierte Weise zur Verfügung gestellt. Die Fertigkeiten der direkten Ophthalmoskopie sind hierbei deutlich schneller als die der indirekten Ophthalmoskopie zu erlernen.
Purpose: To analyze refractive and topographic changes secondary to Descemet membrane endothelial keratoplasty (DMEK) in pseudophakic eyes with Fuchs’ endothelial dystrophy (FED). Methods: Eighty-seven pseudophakic eyes of 74 patients who underwent subsequent DMEK surgery for corneal endothelial decompensation and associated visual impairment were included. Median post-operative follow-up time was 12 months (range: 3–26 months). Main outcome measures were pre- and post-operative manifest refraction, anterior and posterior corneal astigmatism, simulated keratometry (CASimK) and Q value obtained by Scheimpflug imaging. Secondary outcome measures included corrected distance visual acuity (CDVA), central corneal densitometry, central corneal thickness, corneal volume (CV), anterior chamber volume (ACV) and anterior chamber depth (ACD). Results: After DMEK surgery, mean pre-operative spherical equivalent (± SD) changed from + 0.04 ± 1.73 D to + 0.37 ± 1.30 D post-operatively (p = 0.06). CDVA, proportion of emmetropic eyes, ACV and ACD increased significantly during follow-up. There was also a significant decrease in posterior corneal astigmatism, central corneal densitometry, central corneal thickness and corneal volume over time (p = 0.001). Only anterior corneal astigmatism and simulated keratometry (CASimK) remained fairly stable after DMEK. Conclusion: Despite tendencies toward a hyperopic shift, changes in SE were not significant and refraction remained overall stable in pseudophakic patients undergoing DMEK for FED. Analysis of corneal parameters by Scheimpflug imaging mainly revealed changes in posterior corneal astigmatism pointing out the relevance of posterior corneal profile changes during edema resolution after DMEK.
Purpose: To investigate short-term (3 months follow-up) changes in visual quality following Descemet membrane endothelial keratoplasty (DMEK) for Fuchs endothelial dystrophy (FED). Methods: In this prospective institutional case series, 51 patients that underwent DMEK for FED were included. Assessment included the Quality of Vision (QoV) questionnaire preoperatively, at 1 month, and 3 months after surgery. Secondary outcome measures were anterior segment parameters acquired by Scheimpflug imaging, corrected distance visual acuity (CDVA), and endothelial cell density (ECD). Results: Glare, hazy vision, blurred vision, and daily fluctuation in vision were the symptoms mostly reported preoperatively. All symptoms demonstrated a significant reduction of item scores for severity, frequency, and bothersome in the course after DMEK (P < 0.01). Glare and fluctuation in vision remained to some extent during the follow-up period (median score = 1). Preoperatively, corneal densitometry correlated moderately to weakly with severity of hazy vision (rs = 0.39; P = 0.03) and frequency (rs = 0.26; P = 0.02) as well as severity (rs = 0.27; P = 0.03) of blurry vision. CDVA and central corneal thickness (CCT) did not correlate with visual complains. Conclusions: Following DMEK for FED, patient-reported visual symptoms assessed by the QoV questionnaire represent a useful tool providing valuable information on the impact of DMEK on visual quality that cannot be directly estimated by morphological parameters and visual acuity only.
Purpose: To investigate short-term (3 months follow-up) changes in visual quality following Descemet membrane endothelial keratoplasty (DMEK) for Fuchs endothelial dystrophy (FED). Methods: In this prospective institutional case series, 51 patients that underwent DMEK for FED were included. Assessment included the Quality of Vision (QoV) questionnaire preoperatively, at 1 month, and 3 months after surgery. Secondary outcome measures were anterior segment parameters acquired by Scheimpflug imaging, corrected distance visual acuity (CDVA), and endothelial cell density (ECD). Results: Glare, hazy vision, blurred vision, and daily fluctuation in vision were the symptoms mostly reported preoperatively. All symptoms demonstrated a significant reduction of item scores for severity, frequency, and bothersome in the course after DMEK (P < 0.01). Glare and fluctuation in vision remained to some extent during the follow-up period (median score = 1). Preoperatively, corneal densitometry correlated moderately to weakly with severity of hazy vision (rs = 0.39; P = 0.03) and frequency (rs = 0.26; P = 0.02) as well as severity (rs = 0.27; P = 0.03) of blurry vision. CDVA and central corneal thickness (CCT) did not correlate with visual complains. Conclusions: Following DMEK for FED, patient-reported visual symptoms assessed by the QoV questionnaire represent a useful tool providing valuable information on the impact of DMEK on visual quality that cannot be directly estimated by morphological parameters and visual acuity only.
Background: Transplantation of human corneal tissue is associated with the potential risk of transmittance of viral infections. In accordance with European directives and federal laws, in Germany each tissue donor has to be tested for infectious diseases such as hepatitis B and C virus (HBV and HCV) and human immunodeficiency virus (HIV) infection. However, most of the currently available CE-marked serologic and nucleic acid screening systems are only validated for antemortem blood. Methods: Twenty related and paired ante- and postmortem blood samples from cornea donors were obtained and subsequently analyzed for hepatitis B surface antigen (HBsAg), hepatitis B antibody (anti-HBc), anti-HCV, HCV RNA, anti-HIV-1/2, and HIV p24 Ag using Abbott test systems. The sera were also spiked with reference materials in concentrations giving low and high positivity for HBV, HCV, and HIV markers. Results: The spiked ante- and postmortem sera from related donors showed similar results for HBsAg, anti-HBc, anti-HCV, HCV RNA, anti-HIV, and HIV p24 Ag, indicating a high stability of viral markers in cadaveric specimens. Three cornea donors had a medical history of HBV infection and revealed anti-HBc at similar levels in the ante- and postmortem sera. In addition, there was a single postmortem sample demonstrating a weak signal of anti-HIV-1 and HIV-1 p24 Ag. False-positive or false-negative results were not detected. The results obtained with the Abbott ARCHITECT analyzer and Abbott RealTime HCV PCR showed no significant differences. Conclusion: The analyzed screening assays are suitable for the detection of infectious markers of HBV, HCV, and HIV at similar levels in spiked ante- and postmortem sera from cornea donors.