Aims: We sought to describe perfusion dyssynchrony analysis specifically to exploit the high temporal resolution of stress perfusion CMR. This novel approach detects differences in the temporal distribution of the wash-in of contrast agent across the left ventricular wall.
Methods and results: Ninety-eight patients with suspected coronary artery disease (CAD) were retrospectively identified. All patients had undergone perfusion CMR at 3T and invasive angiography with fractional flow reserve (FFR) of lesions visually judged >50% stenosis. Stress images were analysed using four different perfusion dyssynchrony indices: the variance and coefficient of variation of the time to maximum signal upslope (V-TTMU and C-TTMU) and the variance and coefficient of variation of the time to peak myocardial signal enhancement (V-TTP and C-TTP). Patients were classified according to the number of vessels with haemodynamically significant CAD indicated by FFR <0.8. All indices of perfusion dyssynchrony were capable of identifying the presence of significant CAD. C-TTP >10% identified CAD with sensitivity 0.889, specificity 0.857 (P < 0.0001). All indices correlated with the number of diseased vessels. C-TTP >12% identified multi-vessel disease with sensitivity 0.806, specificity 0.657 (P < 0.0001). C-TTP was also the dyssynchrony index with the best inter- and intra-observer reproducibility. Perfusion dyssynchrony indices showed weak correlation with other invasive and non-invasive measurements of the severity of ischaemia, including FFR, visual ischaemic burden, and MPR.
Conclusion: These findings suggest that perfusion dyssynchrony analysis is a robust novel approach to the analysis of first-pass perfusion and has the potential to add complementary information to aid assessment of CAD.
Background: Cardiovascular magnetic resonance (CMR) offers quantification of phasic atrial functions based on volumetric assessment and more recently, on CMR feature tracking (CMR-FT) quantitative strain and strain rate (SR) deformation imaging. Inter-study reproducibility is a key requirement for longitudinal studies but has not been defined for CMR-based quantification of left atrial (LA) and right atrial (RA) dynamics.
Methods: Long-axis 2- and 4-chamber cine images were acquired at 9:00 (Exam A), 9:30 (Exam B) and 14:00 (Exam C) in 16 healthy volunteers. LA and RA reservoir, conduit and contractile booster pump functions were quantified by volumetric indexes as derived from fractional volume changes and by strain and SR as derived from CMR-FT. Exam A and B were compared to assess the inter-study reproducibility. Morning and afternoon scans were compared to address possible diurnal variation of atrial function.
Results: Inter-study reproducibility was within acceptable limits for all LA and RA volumetric, strain and SR parameters. Inter-study reproducibility was better for volumetric indexes and strain than for SR parameters and better for LA than for RA dynamics. For the LA, reservoir function showed the best reproducibility (intraclass correlation coefficient (ICC) 0.94–0.97, coefficient of variation (CoV) 4.5–8.2 %), followed by conduit (ICC 0.78–0.97, CoV 8.2–18.5 %) and booster pump function (ICC 0.71–0.95, CoV 18.3–22.7). Similarly, for the RA, reproducibility was best for reservoir function (ICC 0.76–0.96, CoV 7.5–24.0 %) followed by conduit (ICC 0.67–0.91, CoV 13.9–35.9) and booster pump function (ICC 0.73–0.90, CoV 19.4–32.3). Atrial dynamics were not measurably affected by diurnal variation between morning and afternoon scans.
Conclusions: Inter-study reproducibility for CMR-based derivation of LA and RA functions is acceptable using either volumetric, strain or SR parameters with LA function showing higher reproducibility than RA function assessment. Amongst the different functional components, reservoir function is most reproducibly assessed by either technique followed by conduit and booster pump function, which needs to be considered in future longitudinal research studies.