The aim of this study is to provide a systematic assessment of the influence of the position on the arterial input function (AIF) for perfusion quantification. In 39 patients with a wide range of left ventricular function the AIF was determined using a diluted contrast bolus of a cardiac magnetic resonance imaging in three left ventricular levels (basal, mid, apex) as well as aortic sinus (AoS). Time to peak signal intensities, baseline corrected peak signal intensity and upslopes were determined and compared to those obtained in the AoS. The error induced by sampling the AIF in a position different to the AoS was determined by Fermi deconvolution. The time to peak signal intensity was strongly correlated (r2 > 0.9) for all positions with a systematic earlier arrival in the basal (− 2153 ± 818 ms), the mid (− 1429 ± 928 ms) and the apical slice (− 450 ± 739 ms) relative to the AoS (all p < 0.001). Peak signal intensity as well as upslopes were strongly correlated (r2 > 0.9 for both) for all positions with a systematic overestimation in all positions relative to the AoS (all p < 0.001 and all p < 0.05). Differences between the positions were more pronounced for patients with reduced ejection fraction. The error of averaged MBF quantification was 8%, 13% and 27% for the base, mid and apex. The location of the AIF significantly influences core parameters for perfusion quantification with a systematic and ejection fraction dependent error. Full quantification should be based on obtaining the AIF as close as possible to the myocardium to minimize these errors.
Aims: Preventing hospitalization by detecting early evidence of heart failure (HF) decompensation in an outpatient setting can improve patient's quality of life and reduce costs of care. The purpose of this study was to assess the value of cardiac acoustic biomarkers (CABs), a combination of cardiohaemic vibrations synchronized with ECG signals, and heart rate (HR) for detecting HF decompensation during first 3 months after hospital discharge for HF.
Methods and results: Patients with an ejection fraction ≤35% (HFrEF) and hospitalized for decompensated HF were enrolled in a prospective observational study. All subjects wore a wearable cardioverter‐defibrillator (ZOLL LifeVest®, Pittsburgh, PA, USA) that is capable of recording CABs and HR. The primary endpoint of the study was the first HF event, defined as HF readmission or HF emergency room visit. From June 2017 through August 2019, 671 patients with HFrEF were enrolled. Eighty‐one patients (12.1%) had a total of 112 HF events. The algorithm detected HF events with a median of 32 days (interquartile range = 11‐45) in advance of the first HF event. The algorithm had a sensitivity of 69%, specificity of 60%, positive predictive value of 19%, and a negative predictive value of 94%. Of note, the baseline (first 7 days post‐enrolment) algorithm using CABs and HR was superior to New York Heart Association classification in detecting patients more likely to have HF decompensation (sensitivity and specificity of 61% and 68% vs. 46% and 55%, respectively).
Conclusions: This prospective international registry showed that an algorithm incorporating CABs and HR data detected HF events 30 days in advance of the event in patients with HFrEF during first 3 months after hospital discharge. Therefore, integrating CAB technology into clinical practice may prevent HF rehospitalizations.
Aims: Heart failure (HF) leads to repeat hospitalisations and reduces the duration and quality of life. Pulmonary artery pressure (PAP)‐guided HF management using the CardioMEMS™ HF system was shown to be safe and reduce HF hospitalisation (HFH) rates in New York Heart Association (NYHA) class III patients. However, these findings have not been replicated in health systems outside the United States. Therefore, the CardioMEMS European Monitoring Study for Heart Failure (MEMS‐HF) evaluated the safety, feasibility, and performance of this device in Germany, The Netherlands, and Ireland.
Methods and results: A total of 234 NYHA class III patients (68 ± 11 years, 22% female, ≥1 HFH in the preceding year) from 31 centres were implanted with a CardioMEMS sensor and underwent PAP‐guided HF management. One‐year rates of freedom from device‐ or system‐related complications and from sensor failure (co‐primary outcomes) were 98.3% [95% confidence interval (CI) 95.8–100.0] and 99.6% (95% CI 97.6–100.0), respectively. Survival rate was 86.2%. For the 12 months post‐ vs. pre‐implant, HFHs decreased by 62% (0.60 vs. 1.55 events/patient‐year; hazard ratio 0.38, 95% CI 0.31–0.48; P < 0.0001). After 12 months, mean PAP decreased by 5.1 ± 7.4 mmHg, Kansas City Cardiomyopathy Questionnaire (KCCQ) overall/clinical summary scores increased from 47.0 ± 24.0/51.2 ± 24.8 to 60.5 ± 24.3/62.4 ± 24.1 (P < 0.0001), and the 9‐item Patient Health Questionnaire sum score improved from 8.7 ± 5.9 to 6.3 ± 5.1 (P < 0.0001).
Conclusion: Haemodynamic‐guided HF management proved feasible and safe in the health systems of Germany, The Netherlands, and Ireland. Physician‐directed treatment modifications based on remotely obtained PAP values were associated with fewer HFH, sustainable PAP decreases, marked KCCQ improvements, and remission of depressive symptoms.