Refine
Year of publication
Document Type
- Article (25)
- Part of a Book (7)
- Conference Proceeding (6)
- Doctoral Thesis (1)
- Habilitation (1)
Language
- German (25)
- English (14)
- Multiple languages (1)
Has Fulltext
- yes (40)
Is part of the Bibliography
- no (40)
Keywords
- wassergefiltertes Infrarot A (wIRA) (25)
- Gewebetemperatur (21)
- Gewebedurchblutung (20)
- Wundheilung (20)
- Sauerstoffpartialdruck im Gewebe (19)
- Schmerzminderung (19)
- water-filtered infrared-A (wIRA) (18)
- Infektionsabwehr (16)
- reduction of pain (15)
- tissue oxygen partial pressure (15)
Institute
- Sportwissenschaften (40)
- Medizin (3)
Wassergefiltertes Infrarot A (wIRA) wird erfolgreich in der Wundbehandlung, selbst bei chronischen Problemwunden, eingesetzt. Prof. Dr. Gerd Hoffmann, Facharzt für Innere Medizin, Sportmedizin und Notfallmedizin, Johann Wolfgang Goethe-Universität Frankfurt a. M., erklärt, was bei diesem Verfahren passiert.
Apparent contradiction between negative effects of UV radiation and positive effects of sun exposure
(2005)
We would like to comment on the three contributions in the Journal of the National Cancer Institute, Vol. 97, No. 3, February 2, 2005: Kathleen M. Egan, Jeffrey A. Sosman, William J. Blot: Editorial: Sunlight and Reduced Risk of Cancer: Is the Real Story Vitamin D? (pp. 161-163) ; Marianne Berwick, Bruce K. Armstrong, Leah Ben-Porat, Judith Fine, Anne Kricker, Carey Eberle, Raymond Barnhill: Sun Exposure and Mortality From Melanoma. (pp. 195-199) ; Karin Ekström Smedby, Henrik Hjalgrim, Mads Melbye, Anna Torrång, Klaus Rostgaard, Lars Munksgaard, et al.: Ultraviolet Radiation Exposure and Risk of Malignant Lymphomas. (pp. 199-209).
Im ersten Teil der Publikation werden die Bedeutung von Bewegung und Prävention sowie präventionsbezogene Begriffe erläutert.
Im nächsten Abschnitt werden die Auswirkungen von Bewegungsmangel und von körperlicher Aktivität auf verschiedene Organsysteme dargelegt.
Es folgen die hieraus zu ziehenden Konsequenzen für ein präventiv nutzbares Training. Es werden dabei auch zur Motivierung Sporttreibender einsetzbare Faustregeln zur Leistungsfähigkeit und zur Trainierbarkeit (maximale Sauerstoffaufnahme, maximale ergometrische Leistungsfähigkeit und deren Veränderungen mit dem Alter und ihre Trainierbarkeit) erläutert.
Die infizierte Problemwunde
(2006)
Die erste Ausgabe der Online-Zeitschrift "GMS Krankenhaushygiene Interdisziplinär" der Deutschen Gesellschaft für Krankenhaushygiene (DGKH) innerhalb von German Medical Science behandelt das Thema "Die infizierte Problemwunde". Die Zielsetzung dieser Zeitschrift besteht in der komplexen Darstellung aktueller Themen der Krankenhaushygiene in interdisziplinärer Zusammenarbeit zwischen Hygienikern, Mikrobiologen, Infektiologen und für die jeweilige Thematik relevanten klinischen Fachdisziplinen und ggf. auch mit Experten anderer Fachrichtungen, z.B. Juristen, da rechtliche Aspekte zunehmend Bedeutung erlangen. ...
Background: Water-filtered infrared-A (wIRA) is a special form of heat radiation with high tissue penetration and a low thermal load to the skin surface. wIRA corresponds to the major part of the sun’s heat radiation, which reaches the surface of the Earth in moderate climatic zones filtered by water and water vapour of the atmosphere. wIRA promotes healing of acute and chronic wounds both by thermal and thermic as well as by non-thermal and non-thermic cellular effects.
Methods: This publication includes a literature review with search in PubMed/Medline for “water-filtered infrared-A” and “wound”/”ulcus” or “wassergefiltertes Infrarot A” and “Wunde”/”Ulkus”, respectively (publications in English and German), and additional analysis of study data. Seven prospective clinical studies (of these six randomized controlled trials (RCT), the largest study with n=400 patients) were identified and included. All randomized controlled clinical trials compare a combination of high standard care plus wIRA treatment vs. high standard care alone. The results below marked with “vs.” present these comparisons.
Results:
* wIRA increases tissue temperature (+2.7°C at a tissue depth of 2 cm), tissue oxygen partial pressure (+32% at a tissue depth of 2 cm) and tissue perfusion (effect sizes within the wIRA group).
* wIRA promotes normal as well as disturbed wound healing by diminishing inflammation and exudation, by promotion of infection defense and regeneration, and by alleviation of pain (with respect to alleviation of pain, without any exception during 230 irradiations, 13.4 vs. 0.0 on a visual analogue scale (VAS 0–100), median difference between groups 13.8, 95% confidence interval (CI) 12.3/16.7, p<0.000001) with a substantially reduced need for analgesics (52–69% less in the three groups with wIRA compared to the three control groups in visceral surgery, p=0.000020 and 0.00037 and 0.0045, respectively; total of 6 vs. 14.5 analgesic tablets on 6 surveyed days (of weeks 1–6) in chronic venous stasis ulcers, median difference –8, 95% CI –10/–5, p=0.000002).
Further effects are:
* Faster reduction of wound area (in severely burned children: 90% reduction of wound size after 9 vs. 13 days, after 9 days 89.2% vs. 49.5% reduction in wound area, median difference 39.5% wound area reduction, 95% CI 36.7%/42.2%, p=0.000011; complete wound closure of chronic venous stasis ulcers after 14 vs. 42 days, median difference –21 days, 95% CI –28/–10, p=0.000005).
* Better overall evaluation of wound healing (surgical wounds: 88.6 vs. 78.5 on a VAS 0–100, median difference 8.9, 95% CI 6.1/12.0, p<0.000001).
* Better overall evaluation of the effect of irradiation (79.0 vs. 46.8 on a VAS 0–100 with 50 as neutral point, median difference 27.9, 95% CI 19.8/34.6, p<0.000001).
* Higher tissue oxygen partial pressure during irradiation with wIRA (at a tissue depth of 2 cm 41.6 vs. 30.2 mmHg, median difference 11.9 mmHg, 95% CI 9.6/14.2 mmHg, p<0.000001).
* Higher tissue temperature during irradiation with wIRA (at a tissue depth of 2 cm 38.9 vs. 36.4°C, median difference 2.6°C, 95% CI 2.2/2.9°C, p<0.000001).
* Better cosmetic result (84.5 vs. 76.5 on a VAS 0–100, median difference 7.9, 95% CI 3.7/12.0, p=0.00027).
* Lower wound infection rate (single preoperative irradiation: 5.1% vs. 12.1% wound infections in total, difference –7.0%, 95% CI –12.8%/–1.3%, p=0.017, of these: late wound infections (postoperative days 9-30) 1.7% vs. 7.7%, difference –6.0%, 95% CI –10.3%/–1.7%, p=0.007).
* Shorter hospital stay (9 vs. 11 postoperative days, median difference –2 days, 95% CI –3/0 days, p=0.022).
Most of the effects have been proven with an evidence level of 1a or 1b.
Conclusion: Water-filtered infrared-A is a useful complement for the treatment of acute and chronic wounds.
Keywords: water-filtered infrared-A (wIRA), wound healing, acute and chronic wounds, reduction of pain, tissue oxygen partial pressure, tissue temperature
Background: Water-filtered infrared-A (wIRA) is a special form of heat radiation with a high tissue-penetration and with a low thermal burden to the surface of the skin. wIRA is able to improve essential and energetically meaningful factors of wound healing by thermal and non-thermal effects.
Aim of the study: prospective study (primarily planned randomised, controlled, blinded, de facto with one exception only one cohort possible) using wIRA in the treatment of patients with recalcitrant chronic venous stasis ulcers of the lower legs with thermographic follow-up.
Methods: 10 patients (5 males, 5 females, median age 62 years) with 11 recalcitrant chronic venous stasis ulcers of the lower legs were treated with water-filtered infrared-A and visible light irradiation (wIRA(+VIS), Hydrosun® radiator type 501, 10 mm water cuvette, water-filtered spectrum 550–1400 nm) or visible light irradiation (VIS; only possible in one patient). The uncovered wounds of the patients were irradiated two to five times per week for 30 minutes at a standard distance of 25 cm (approximately 140 mW/cm2 wIRA and approximately 45 mW/cm2 VIS). Treatment continued for a period of up to 2 months (typically until closure or nearly closure of the ulcer). The main variable of interest was “percent change of ulcer size over time” including complete wound closure. Additional variables of interest were thermographic image analysis, patient’s feeling of pain in the wound, amount of pain medication, assessment of the effect of the irradiation (by patient and by clinical investigator), assessment of feeling of the wound area (by patient), assessment of wound healing (by clinical investigator) and assessment of the cosmetic state (by patient and by clinical investigator). For these assessments visual analogue scales (VAS) were used.
Results: The study showed a complete or nearly complete healing of lower leg ulcers in 7 patients and a clear reduction of ulcer size in another 2 of 10 patients, a clear reduction of pain and pain medication consumption (e.g. from 15 to 0 pain tablets per day), and a normalization of the thermographic image (before the beginning of the therapy typically hyperthermic rim of the ulcer with relative hypothermic ulcer base, up to 4.5°C temperature difference). In one patient the therapy of an ulcer of one leg was performed with the fully active radiator (wIRA(+VIS)), while the therapy of an ulcer of the other leg was made with a control group radiator (only VIS without wIRA), showing a clear difference in favour of the wIRA treatment. All mentioned VAS ratings improved remarkably during the period of irradiation treatment, representing an increased quality of life. Failures of complete or nearly complete wound healing were seen only in patients with arterial insufficiency, in smokers or in patients who did not have venous compression garment therapy.
Discussion and conclusions: wIRA can alleviate pain considerably (with an impressive decrease of the consumption of analgesics) and accelerate wound healing or improve a stagnating wound healing process and diminish an elevated wound exudation and inflammation both in acute and in chronic wounds (in this study shown in chronic venous stasis ulcers of the lower legs) and in problem wounds including infected wounds. In chronic recalcitrant wounds complete healing is achieved, which was not reached before. Other studies have shown that even without a disturbance of wound healing an acute wound healing process can be improved (e.g. reduced pain) by wIRA.
wIRA is a contact-free, easily used and pleasantly felt procedure without consumption of material with a good penetration effect, which is similar to solar heat radiation on the surface of the earth in moderate climatic zones. Wound healing and infection defence (e.g. granulocyte function including antibacterial oxygen radical formation of the granulocytes) are critically dependent on a sufficient energy supply (and on sufficient oxygen). The good clinical effect of wIRA on wounds and also on problem wounds and wound infections can be explained by the improvement of both the energy supply and the oxygen supply (e.g. for the granulocyte function). wIRA causes as a thermal effect in the tissue an improvement in three decisive factors: tissue oxygen partial pressure, tissue temperature and tissue blood flow. Besides this non-thermal effects of infrared-A by direct stimulation of cells and cellular structures with reactions of the cells have also been described. It is concluded that wIRA can be used to improve wound healing, to reduce pain, exudation, and inflammation and to increase quality of life.
Aim of the study: Investigation, whether water-filtered infrared-A (wIRA) irradiation during moderate bicycle ergometer endurance exercise has effects especially on local fat reduction and on weight reduction beyond the effects of ergometer exercise alone.
Methods: Randomised controlled study with 40 obese females (BMI 30-40 (median: 34.5), body weight 76-125 (median: 94.9) kg, age 20-40 (median: 35.5) years, isocaloric nutrition), 20 in the wIRA group and 20 in the control group. In both groups each participant performed 3 times per week over 4 weeks for 45 minutes bicycle ergometer endurance exercise with a constant load according to a lactate level of 2 mmol/l (aerobic endurance load, as determined before the intervention period). In the wIRA group in addition large parts of the body (including waist, hip, and thighs) were irradiated during all ergometries of the intervention period with visible light and a predominant part of water-filtered infrared-A (wIRA), using the irradiation unit “Hydrosun® 6000” with 10 wIRA radiators (Hydrosun® Medizintechnik, Müllheim, Germany, radiator type 500, 4 mm water cuvette, yellow filter, water-filtered spectrum 500-1400 nm) around a speed independent bicycle ergometer.
Main variable of interest: change of “the sum of circumferences of waist, hip, and both thighs of each patient” over the intervention period (4 weeks). Additional variables of interest: body weight, body mass index BMI, body fat percentage, fat mass, fat-free mass, water mass (analysis of body composition by tetrapolar bioimpedance analysis), assessment of an arteriosclerotic risk profile by blood investigation of variables of lipid metabolism (cholesterol, triglycerides, high density lipoproteins HDL, low density lipoproteins LDL, apolipoprotein A1, apolipoprotein B), clinical chemistry (fasting glucose, alanin-aminotransferase ALT (= glutamyl pyruvic transaminase GPT), gamma-glutamyl-transferase GGT, creatinine, albumin), endocrinology (leptin, adiponectin (= adipo Q), homocysteine, insulin). All variables were at least measured before and after the intervention period. Ergometry (ECG, blood pressure behaviour, lactate curve with power at 2, 3 and 4 mmol/l) before the intervention period. In addition: nutrition training ahead of and during the intervention period with a nutrition protocol over one week for assessment of the daily energy intake; calculation of basic metabolic rate and total energy requirement. Assessment of undesired effects.
Only methods of non-parametric statistics were used, both descriptive (median, percentiles of 25 and 75 (= interquartile range), minimum, maximum) and confirmatory (two-sided Mann-Whitney U test for unpaired samples for the only one main variable of interest). Total error probability: .05 (5%). An intention to treat analysis ITT with last observed carry forward method was used preferably (presented results) and in addition an on treatment analysis OT. Only 2 (treatment group) and 4 (control group) drop-outs occurred (mostly due to lack of time).
Results: The “sum of circumferences of waist, hip, and both thighs of each patient” decreased during the 4 weeks significantly more (p<.001) in the wIRA group than in the control group: medians and interquartile ranges: -8.0 cm (-10.5 cm/-4.1 cm) vs. -1.8 cm (-4.4 cm/0.0 cm).
As well “body weight of each patient” decreased during the 4 weeks markedly more in the wIRA group than in the control group: medians and interquartile ranges: -1.9 kg (-4.0 kg/0.0 kg) vs. 0.0 kg (-1.5 kg/+0.4 kg); median of body weight changed from 99.3 kg to 95.6 kg (wIRA) vs. 89.9 kg to 89.6 kg (control). A similar effect showed the body mass index BMI.
Blood variables of interest remained unchanged or showed some slight improvements during the treatment period, concerning most variables with no obvious differences between the two groups; insulin showed a slight trend to decrease in the wIRA group and to increase in the control group.
Undesired effects of the treatment were not seen.
Discussion: The results of the study suggest, that wIRA – during moderate bicycle ergometer endurance exercise as lipolytic stimulus – increases local lipolysis with a local fat reduction (thighs) in the otherwise bradytrophic fatty tissue. The presumably underlying mechanisms of wIRA have already been proven: wIRA acts both by thermal effects and by non-thermal effects. Thermal effects of wIRA are the generation of a therapeutic field of warmth with the increase of tissue temperature, tissue oxygen partial pressure, and tissue blood flow, and by this regional metabolism. As fatty tissue normally has a slow metabolism (bradytrophic and hypothermic tissue) with a low rate of lipolysis, wIRA can increase lipolysis in fatty tissue and the mobilized fats are burned in musculature during the ergometer exercise.
Conclusion: The results of the study indicate, that wIRA irradiation during moderate ergometer endurance exercise can be used – in combination with an appropriate nutrition – to improve body composition, especially local fat distribution, and the reduction of fat and body weight in obese persons.
Keywords: water-filtered infrared-A (wIRA), weight reduction, local fat reduction, bicycle ergometer endurance exercise, lipolysis, randomised controlled study, intervention trial, body weight, body mass index BMI, analysis of body composition, tetrapolar bioimpedance analysis, lactate, lipid metabolism, cholesterol, triglycerides, high density lipoproteins HDL, low density lipoproteins LDL
Aim of the study: Investigation, whether water-filtered infrared-A (wIRA) irradiation during moderate bicycle ergometer endurance exercise has effects especially on local fat reduction and on weight reduction beyond the effects of ergometer exercise alone.
Methods: Randomised controlled study with 40 obese females (BMI 30-40 (median: 34.5), body weight 76-125 (median: 94.9) kg, age 20-40 (median: 35.5) years, isocaloric nutrition), 20 in the wIRA group and 20 in the control group. In both groups each participant performed 3 times per week over 4 weeks for 45 minutes bicycle ergometer endurance exercise with a constant load according to a lactate level of 2 mmol/l (aerobic endurance load, as determined before the intervention period). In the wIRA group in addition large parts of the body (including waist, hip, and thighs) were irradiated during all ergometries of the intervention period with visible light and a predominant part of water-filtered infrared-A (wIRA), using the irradiation unit “Hydrosun® 6000” with 10 wIRA radiators (Hydrosun® Medizintechnik, Müllheim, Germany, radiator type 500, 4 mm water cuvette, yellow filter, water-filtered spectrum 500-1400 nm) around a speed independent bicycle ergometer.
Main variable of interest: change of “the sum of circumferences of waist, hip, and both thighs of each patient” over the intervention period (4 weeks). Additional variables of interest: body weight, body mass index BMI, body fat percentage, fat mass, fat-free mass, water mass (analysis of body composition by tetrapolar bioimpedance analysis), assessment of an arteriosclerotic risk profile by blood investigation of variables of lipid metabolism (cholesterol, triglycerides, high density lipoproteins HDL, low density lipoproteins LDL, apolipoprotein A1, apolipoprotein B), clinical chemistry (fasting glucose, alanin-aminotransferase ALT (= glutamyl pyruvic transaminase GPT), gamma-glutamyl-transferase GGT, creatinine, albumin), endocrinology (leptin, adiponectin (= adipo Q), homocysteine, insulin). All variables were at least measured before and after the intervention period. Ergometry (ECG, blood pressure behaviour, lactate curve with power at 2, 3 and 4 mmol/l) before the intervention period. In addition: nutrition training ahead of and during the intervention period with a nutrition protocol over one week for assessment of the daily energy intake; calculation of basic metabolic rate and total energy requirement. Assessment of undesired effects.
Only methods of non-parametric statistics were used, both descriptive (median, percentiles of 25 and 75 (= interquartile range), minimum, maximum) and confirmatory (two-sided Mann-Whitney U test for unpaired samples for the only one main variable of interest). Total error probability: .05 (5%). An intention to treat analysis ITT with last observed carry forward method was used preferably (presented results) and in addition an on treatment analysis OT. Only 2 (treatment group) and 4 (control group) drop-outs occurred (mostly due to lack of time).
Results: The “sum of circumferences of waist, hip, and both thighs of each patient” decreased during the 4 weeks significantly more (p<.001) in the wIRA group than in the control group: medians and interquartile ranges: -8.0 cm (-10.5 cm/-4.1 cm) vs. -1.8 cm (-4.4 cm/0.0 cm).
As well “body weight of each patient” decreased during the 4 weeks markedly more in the wIRA group than in the control group: medians and interquartile ranges: -1.9 kg (-4.0 kg/0.0 kg) vs. 0.0 kg (-1.5 kg/+0.4 kg); median of body weight changed from 99.3 kg to 95.6 kg (wIRA) vs. 89.9 kg to 89.6 kg (control). A similar effect showed the body mass index BMI.
Blood variables of interest remained unchanged or showed some slight improvements during the treatment period, concerning most variables with no obvious differences between the two groups; insulin showed a slight trend to decrease in the wIRA group and to increase in the control group.
Undesired effects of the treatment were not seen.
Discussion: The results of the study suggest, that wIRA – during moderate bicycle ergometer endurance exercise as lipolytic stimulus – increases local lipolysis with a local fat reduction (thighs) in the otherwise bradytrophic fatty tissue. The presumably underlying mechanisms of wIRA have already been proven: wIRA acts both by thermal effects and by non-thermal effects. Thermal effects of wIRA are the generation of a therapeutic field of warmth with the increase of tissue temperature, tissue oxygen partial pressure, and tissue blood flow, and by this regional metabolism. As fatty tissue normally has a slow metabolism (bradytrophic and hypothermic tissue) with a low rate of lipolysis, wIRA can increase lipolysis in fatty tissue and the mobilized fats are burned in musculature during the ergometer exercise.
Conclusion: The results of the study indicate, that wIRA irradiation during moderate ergometer endurance exercise can be used – in combination with an appropriate nutrition – to improve body composition, especially local fat distribution, and the reduction of fat and body weight in obese persons.