Refine
Document Type
- Article (2) (remove)
Language
- English (2)
Has Fulltext
- yes (2)
Is part of the Bibliography
- no (2)
Keywords
- Hemodynamics (2) (remove)
Institute
- Medizin (2)
Aims: Balloon pulmonary angioplasty (BPA) is an interventional treatment modality for inoperable chronic thromboembolic pulmonary hypertension (CTEPH). Therapy monitoring, based on non-invasive biomarkers, is a clinical challenge. This post-hoc study aimed to assess dynamics of high-sensitivity cardiac troponin T (hs-cTnT) as a marker for myocardial damage and its relation to N-terminal pro-B-type natriuretic peptide (NT-proBNP) levels as a marker for cardiac wall stress.
Methods and results: This study included 51 consecutive patients who underwent BPA treatment and completed a 6-month follow-up (6-MFU) between 3/2014 and 3/2017. Biomarker measurement was performed consecutively prior to each BPA and at 6-MFU.
In total, the 51 patients underwent an average of 5 BPA procedures. The 6-month survival rate was 96.1%. The baseline (BL) meanPAP (39.5±12.1mmHg) and PVR (515.8±219.2dyn×sec×cm-5) decreased significantly within the 6-MFU (meanPAP: 32.6±12.6mmHg, P<0.001; PVR: 396.9±182.6dyn×sec×cm-5, P<0.001). At BL, the median hs-cTnT level was 11 (IQR 6–16) ng/L and the median NT-proBNP level was 820 (IQR 153–1872) ng/L. The levels of both biomarkers decreased steadily after every BPA, showing the first significant difference after the first procedure. Within the 6-MFU, hs-cTnT levels (7 [IQR 5–12] ng/L; P<0.001) and NT-proBNP levels (159 [IQR 84–464] ng/l; P<0.001) continued to decrease. The hs-cTnT levels correlated with the PVR (rrs = 0.42; p = 0.005), the meanPAP (rrs = 0.32; p = 0.029) and the NT-proBNP (rrs = 0.51; p<0.001) levels at BL.
Conclusion: Non-invasive biomarker measurement provides valuable evidence for the decreasing impairment of myocardial function and structure during BPA therapy. Changes in hs-cTNT levels are suggestive for a reduction in ongoing myocardial damage.
Replacement of a stenotic aortic valve reduces immediately the ventricular to aortic gradient and is expected to improve diastolic and systolic left ventricular function over the long term. However, the hemodynamic changes immediately after valve implantation are so far poorly understood. Within this pilot study, we performed an invasive pressure volume loop analysis to describe the early hemodynamic changes after transcatheter aortic valve implantation (TAVI) with self-expandable prostheses. Invasive left ventricular pressure volume loop analysis was performed in 8 patients with aortic stenosis (mean 81.3 years) prior and immediately after transfemoral TAVI with a self-expandable valve system (St. Jude Medical Portico Valve). Parameters for global hemodynamics, afterload, contractility and the interaction of the cardiovascular system were analyzed. Left ventricular ejection fraction, (53.9% vs. 44.8%, p = 0.018), preload recruitable stroke work (68.5 vs. 44.8 mmHg, p = 0.012) and end-systolic elastance (3.55 vs. 2.17, p = 0.036) both marker for myocardial contractility declined significantly compared to baseline. As sign of impaired diastolic function, TAU, a preload-independent measure of isovolumic relaxation (37.3 vs. 41.8 ms, p = 0.018) and end-diastolic pressure (13.1 vs. 16.4 mmHg, p = 0.015) raised after valve implantation. Contrarily, a smaller ratio of end-systolic to arterial elastance (ventricular-arterial coupling) indicates an improvement of global cardiovascular energy efficiency (1.40 vs. 0.97 p = 0.036). Arterial elastance had a strong correlation with the number of conducted rapid ventricular pacings (Pearson correlation coefficient, r = 0.772, p = 0.025). Invasive left ventricular pressure volume loop analysis revealed impaired systolic and diastolic function in the early phase after TAVI with self-expandable valve for the treatment of severe aortic stenosis. Contrarily, we found indications for early improvement of global cardiovascular energy efficiency.