Background: The introduction of modern troponin assays has facilitated diagnosis of acute myocardial infarction due to improved sensitivity with corresponding loss of specificity. Atrial fibrillation (AF) is associated with elevated levels of troponin. The aim of the present study was to evaluate the diagnostic performance of troponin I in patients with suspected acute coronary syndrome and chronic AF.
Methods: Contemporary sensitive troponin I was assayed in a derivation cohort of 90 patients with suspected acute coronary syndrome and chronic AF to establish diagnostic cut-offs. These thresholds were validated in an independent cohort of 314 patients with suspected myocardial infarction and AF upon presentation. Additionally, changes in troponin I concentration within 3 hours were used.
Results: In the derivation cohort, optimized thresholds with respect to a rule-out strategy with high sensitivity and a rule-in strategy with high specificity were established. In the validation cohort, application of the rule-out cut-off led to a negative predictive value of 97 %. The rule-in cut-off was associated with a positive predictive value of 88 % compared with 71 % if using the 99th percentile cut-off. In patients with troponin I levels above the specificity-optimized threshold, additional use of the 3-hour change in absolute/relative concentration resulted in a further improved positive predictive value of 96 %/100 %.
Conclusions: Troponin I concentration and the 3-hour change in its concentration provide valid diagnostic information in patients with suspected myocardial infarction and chronic AF. With regard to AF-associated elevation of troponin levels, application of diagnostic cut-offs other than the 99th percentile might be beneficial.
Device-related infections in recipients of left ventricular assist devices (LVAD) have been recognized as a major source of morbidity and mortality. They require a high level of diagnostic effort as part of the overall burden resulting from infectious complications in LVAD recipients. We present a multi-allergic patient who was treated for persistent sterile intrathoracic abscess formation and pericardial empyema following minimally invasive LVAD implantation including use of a sheet of e-polytetrafluoroethylene (ePTFE) membrane to restore pericardial integrity. Sterile abscess formation and pericardial empyema recurred after surgical removal until the ePTFE membrane was removed, suggesting that in disposed patients, ePTFE may be related to sterile abscess formation or sterile empyema.