Aortic stenosis is the most common valvular disease worldwide. With transcatheter aortic valve replacement (TAVR) being increasingly expanded to lower-risk populations, several challenging issues remain to be solved. The present review aims at discussing modern approaches to such issues as well as the current status of TAVR. TAVR has undergone several developments in the recent years: an increased use of transfemoral access, the development of prostheses in order to adapt to challenging anatomies, improved delivery systems with repositioning features, and outer skirts aiming at reducing paravalvular leak. The indication of TAVR is increasingly being expanded to patients with lower surgical risk. The main clinical trials supporting such expansion are reviewed and the latest data on low-risk patients are discussed. A number of challenges need still to be addressed and are also reviewed in this paper: the need for updated international guidelines including the latest evidence; a reduction of main complications such as permanent pacemaker implantation, paravalvular leak, and stroke (and its potential prevention by using anti-embolic protection devices); the appropriate role of TAVR in patients with concomitant cardiac ischemic disease; and durability of bio-prosthetic implanted valves. Finally, the future perspectives for TAVR use and next device developments are discussed.
Background: Cerebral O2 saturation (ScO2) reflects cerebral perfusion and can be measured noninvasively by near-infrared spectroscopy (NIRS). Objectives: In this pilot study, we describe the dynamics of ScO2 during TAVI in nonventilated patients and its impact on procedural outcome. Methods and Results: We measured ScO2 of both frontal lobes continuously by NIRS in 50 consecutive analgo-sedated patients undergoing transfemoral TAVI (female 58%, mean age 80.8 years). Compared to baseline ScO2 dropped significantly during RVP (59.3% vs. 53.9%, p < .01). Five minutes after RVP ScO2 values normalized (post RVP 62.6% vs. 53.9% during RVP, p < .01; pre 61.6% vs. post RVP 62.6%, p = .53). Patients with an intraprocedural pathological ScO2 decline of >20% (n = 13) had higher EuroSCORE II (3.42% vs. 5.7%, p = .020) and experienced more often delirium (24% vs. 62%, p = .015) and stroke (0% vs. 23%, p < .01) after TAVI. Multivariable logistic regression revealed higher age and large ScO2 drops as independent risk factors for delirium. Conclusions: During RVP ScO2 significantly declined compared to baseline. A ScO2 decline of >20% is associated with a higher incidence of delirium and stroke and a valid cut-off value to screen for these complications. NIRS measurement during TAVI procedure may be an easy to implement diagnostic tool to detect patients at high risks for cerebrovascular complications and delirium.
Low serum concentrations of the amino acid homoarginine (HA) are associated with increased cardiovascular mortality by incompletely understood mechanisms. This study sought to assess the influence of HA on cardiac remodeling in rats undergoing either transaortic banding or inhibition of nitric oxide synthesis by Nω-Nitro-L-arginine methyl ester hydrochloride (L-NAME). Male Wistar rats (n = 136) underwent sham operation (SH) or aortic banding (AB). Both groups were equally divided into 14 subgroups, receiving different doses of HA alone or in combination with lisinopril, spironolactone, or L-NAME for 4 weeks. HA treatment in AB animals resulted in a dose-dependent improvement of cardiac function up to a concentration of 800 mg·kg−1·day−1. Combining 800 mg·kg−1·day−1 HA with spironolactone or lisinopril yielded additional effects, showing a positive correlation with LV ejection fraction (+33%, p = 0.0002) and fractional shortening (+41%, p = 0.0014). An inverse association was observed with collagen area fraction (−41%, p < 0.0001), myocyte cross-sectional area (−22%, p < 0.0001) and the molecular markers atrial natriuretic factor (−74%, p = 0.0091), brain natriuretic peptide (−42%, p = 0.0298), beta-myosin heavy chain (−46%, p = 0.0411), and collagen type V alpha 1 chain (−73%, p = 0.0257) compared to placebo-treated AB animals. Co-administration of HA and L-NAME was found to attenuate cardiac remodeling and prevent NO-deficient hypertension following AB. HA treatment has led to a dose-dependent improvement of myocardial function and marked histological and molecular changes in cardiac remodeling following AB. Combining HA with standard heart failure medication resulted in additional beneficial effects boosting its direct impact on heart failure pathophysiology.
Background: Valvular aortic stenosis is a common disease in the elderly, often in multimorbid patients. It is often associated with coronary artery disease and peripheral artery disease. In this situation, the risk of conventional open-heart surgery is too high, and other treatment strategies have to be evaluated.
Case report: A 79-year-old female patient with severe aortic stenosis, coronary artery disease and end-stage chronic obstructive pulmonary disease suffering from dyspnea at rest and permanently dependent on oxygen was treated in three steps. Firstly, her pulmonary infection was treated with antibiotics for 7 days. Then, the left anterior descending artery was stented (bare-metal stent). In the same session, valvuloplasty of the aortic valve was performed. She was sent to rehabilitation to improve her pulmonary condition and took clopidogrel for 4 weeks. Finally, she underwent transapical aortic valve replacement. She was released to rehabilitation on postoperative day 12.
Conclusion: A combination of modern interventional and minimally invasive surgical techniques to treat aortic stenosis and coronary heart disease can be a viable option for multimorbid patients with extremely high risk in conventional open-heart surgery.
Background: The aim of this study was to identify pre-operative parameters able to predict length of stay (LoS) based on clinical data and patient-reported outcome measures (PROMs) from a scorecard database in patients with significant aortic stenosis who underwent TAVI (transfemoral aortic valve implantation). Methods: 302 participants (51.7% males, age range 78.2–84.2 years.) were prospectively recruited. After computing the median LoS value (=6 days, range = 5–8 days), we implemented a decision tree algorithm by setting dichotomized values at median LoS as the dependent variable and assessed baseline clinical variables and PROMs (Clinical Frailty Scale (CFS), EuroQol-5 Dimension-5 Levels (EQ-5D) and Kansas City Cardiomyopathy Questionnaire (KCCQ)) as potential predictors. Results: Among clinical parameters, only peripheral arterial disease (p = 0.029, HR = 1.826) and glomerular filtration rate (GFR, cut-off < 33 mL/min/1.73 m2, p = 0.003, HR = 2.252) were predictive of LoS. Additionally, two PROMs (CFS; cut-off = 3, p < 0.001, HR = 1.324 and KCCQ; cut-off = 30, p = 0.003, HR = 2.274) were strong predictors. Further, a risk score for LoS (RS_LoS) was calculated based on these predictors. Patients with RS_LoS = 0 had a median LoS of 5 days; patients RS_LoS ≥ 3 had a median LoS of 8 days. Conclusions: based on the pre-operative values of the above four predictors, a personalized prediction of LoS after TAVI can be achieved.
Background: Rates of permanent pacemaker implantation (PPI) have been low using the self‐expanding ACURATE neo device, but data regarding risk factors of PPI for this specific device are scarce.
Methods: The study cohort consisted of patients (n = 1000) with severe aortic stenosis undergoing transfemoral transcatheter aortic valve implantation (TAVI) using the ACURATE neo prosthesis in our center between May 2012 and December 2019. For the present analysis, we excluded patients with previous permanent pacemaker (n = 110), high‐grade AV block prior to TAVI (n = 3), and patients requiring conversion to surgical valve replacement (n = 4) or the implantation of a second prosthesis as valve‐in‐valve (n = 15). Preexisting conduction abnormalities were determined, and the implantation depth of the prosthesis was measured on final angiography. Differences across quartiles based on the original consecutive cohort were analyzed with respect to implantation depth and PPI rate. Predictors of PPI were identified using logistic regression.
Results: The PPI rate was 10%. Preexisting AV block I°, right bundle branch block (RBBB), and the implantation depth were independent predictors of PPI. Across quartiles, the implantation depth differed significantly with lowest values in the last quartile, whereas differences of PPI rates across quartiles were not statistically significant, but showed a notable decrease in the last quartile.
Conclusion: Preexisting RBBB, AV block I°, and low implantation depth were independent predictors of PPI following TAVI using the ACURATE neo device. Instead of deliberately aiming at a high position, avoidance of a low implantation depth may represent a reasonable compromise to reduce the rate of PPI without increasing the risk of malpositioning.
Objectives: The SAVI-TF (Symetis ACURATE neo Valve Implantation Using Transfemoral Access) registry was initiated to study the ACURATE neo transcatheter heart valve in a large patient population treated under real-world conditions.
Background: The self-expanding, supra-annular ACURATE neo prosthesis is a transcatheter heart valve that gained the Conformité Européene mark in 2014, but only limited clinical data are available so far.
Methods: This prospective, multicenter registry enrolled 1,000 patients at 25 European centers who were followed for 1 year post-procedure.
Results: Mean patient age was 81.1 ± 5.2 years; mean logistic European System for Cardiac Operative Risk Evaluation I score, European System for Cardiac Operative Risk Evaluation II score, and Society of Thoracic Surgeons score were 18.1 ± 12.5%, 6.6 ± 7.5%, and 6.0 ± 5.6%, respectively. At 1 year, 8.0% (95% confidence interval [CI]: 6.3% to 9.7%) of patients had died, 2.3% (95% CI: 1.3% to 3.2%) had disabling strokes, and 9.9% (95% CI: 8.1% to 11.8%) had permanent pacemaker implantations. Through 1 year, 5 reinterventions (0.5%; 95% CI: 0.1% to 1.0%) were performed: 3 valve-in-valve and 2 surgical aortic valve replacements. Mean effective orifice area was 1.84 ± 0.43 cm2, mean gradient was 7.3 ± 3.7 mm Hg, and greater than mild paravalvular leakage was observed in 3.6% of patients.
Conclusions: Transfemoral implantation of the ACURATE neo prosthesis resulted in favorable 1-year clinical and echocardiographic outcomes with very low mortality and new pacemaker rates.
Background: Aortic stenosis (AS) is the most prevalent primary heart valve disease and the third most prevalent cardiovascular disease in the world, having a severe and slowly progressive evolution. The implementation of Transcatheter Aortic Valve Implantation (TAVI) is necessary because the population is constantly ageing, and most elderly people have various comorbidities, which places them among patients with high surgical risk. The aim was to report immediate and 9 months follow-up results of first TAVI implantations in the Republic of Moldova.
Material and methods: Three patients with severe symptomatic AS and high surgical risk underwent TAVI implantation using Portico valves.
Results: The mean age was 76.7 ± 1.2 years, 2 women and 1 man. The mean Logistic EuroSCORE II was 5.68 ± 0.67%. Procedural success was achieved in all (100%) patients. After the intervention, it was shown that the GP mean decreased by an average of 20.27±1.61 mmHg, the Vmax of the jet through AoV decreased on average by 2.05±0.19 m/s, and they were maintained all over the nine months follow-up period. Quality of life, using the TASQ (Toronto Aortic Stenosis Quality of Life) questionnaire, was improved by 62.3 ± 2.2 points.
Conclusions: TAVI, as a new minimally invasive method of treatment for aortic valve stenosis appears to be safe, with a low rate of early and late complications in elderly patients at high surgical risk, with good clinical outcomes at 9 months. Its implementation in the Republic of Moldova is welcome in the conditions of continuously ageing population and the prevalence of associated comorbidities.