Refine
Year of publication
- 2020 (2) (remove)
Document Type
- Article (2)
Language
- English (2)
Has Fulltext
- yes (2)
Is part of the Bibliography
- no (2) (remove)
Keywords
- adiabatic saturation (1)
- auditory fMRI (1)
- cortex, gray matter (1)
- diffusion tensor imaging (1)
- fractional anisotropy (1)
- mean diffusivity (1)
- multiple sclerosis (1)
- scanner noise (1)
- sparse imaging (1)
- steady-state condition (1)
Institute
- Medizin (2)
Purpose: Diffuse cortical damage in relapsing–remitting multiple sclerosis (RRMS) is clinically relevant but cannot be directly assessed with conventional MRI. In this study, it was aimed to use diffusion tensor imaging (DTI) techniques with optimized intrinsic eddy current compensation to quantify and characterize cortical mean diffusivity (MD) and fractional anisotropy (FA) changes in RRMS and to analyze the distribution of these changes across the cortex.
Materials and Methods: Three-Tesla MRI acquisition, mapping of the MD providing information about the integrity of microstructural barriers and of the FA reflecting axonal density and surface-based analysis with Freesurfer were performed for 24 RRMS patients and 25 control subjects.
Results: Across the whole cortex, MD was increased in patients (p < 0.001), while surface-based analysis revealed focal cortical FA decreases. MD and FA changes were distributed inhomogeneously across the cortex, the MD increase being more widespread than the FA decrease. Cortical MD correlated with the Expanded Disability Status Scale (EDSS, r = 0.38, p = 0.03).
Conclusion: Damage of microstructural barriers occurs inhomogeneously across the cortex in RRMS and might be spatially more widespread than axonal degeneration. The results and, in particular, the correlation with the clinical status indicate that DTI might be a promising technique for the monitoring of cortical damage under treatment in larger clinical studies.
Purpose: Auditory functional MRI (fMRI) often uses silent inter-volume delays for stimulus presentation. However, maintaining the steady-state of the magnetization usually requires constant delays. Here, a novel acquisition scheme dubbed “pre-Saturated EPI using Multiple delays in Steady-state” (SEPIMS) is proposed, using spin saturation at a fixed delay before each volume to maintain steady-state conditions, independent of previous spin history. This concept allows for variable inter-volume delays and thus for flexible stimulus design in auditory fMRI. The purpose was to compare the signal stability of SEPIMS and conventional sparse EPI (CS-EPI). Methods: The saturation module comprises two non-selective adiabatic saturation pulses. The efficiency of the saturation and its effect on the SEPIMS signal stability is tested in vitro and in vivo. Results: Data show that SEPIMS yields the same signal stability as CS-EPI, even for extreme variations between inter-volume delay durations. However, dual saturation pulses are required to achieve sufficiently high saturation efficiency in compartments with long T1 values. Importantly, spoiler gradient pulses after the EPI readout have to be optimized to avoid eddy-current-induced image distortions. Conclusion: The proposed SEPIMS sequence maintains high signal stability in the presence of variable inter-volume durations, thus allowing for flexible stimulus design.