Background: Cerebral O2 saturation (ScO2) reflects cerebral perfusion and can be measured noninvasively by near-infrared spectroscopy (NIRS). Objectives: In this pilot study, we describe the dynamics of ScO2 during TAVI in nonventilated patients and its impact on procedural outcome. Methods and Results: We measured ScO2 of both frontal lobes continuously by NIRS in 50 consecutive analgo-sedated patients undergoing transfemoral TAVI (female 58%, mean age 80.8 years). Compared to baseline ScO2 dropped significantly during RVP (59.3% vs. 53.9%, p < .01). Five minutes after RVP ScO2 values normalized (post RVP 62.6% vs. 53.9% during RVP, p < .01; pre 61.6% vs. post RVP 62.6%, p = .53). Patients with an intraprocedural pathological ScO2 decline of >20% (n = 13) had higher EuroSCORE II (3.42% vs. 5.7%, p = .020) and experienced more often delirium (24% vs. 62%, p = .015) and stroke (0% vs. 23%, p < .01) after TAVI. Multivariable logistic regression revealed higher age and large ScO2 drops as independent risk factors for delirium. Conclusions: During RVP ScO2 significantly declined compared to baseline. A ScO2 decline of >20% is associated with a higher incidence of delirium and stroke and a valid cut-off value to screen for these complications. NIRS measurement during TAVI procedure may be an easy to implement diagnostic tool to detect patients at high risks for cerebrovascular complications and delirium.
Replacement of a stenotic aortic valve reduces immediately the ventricular to aortic gradient and is expected to improve diastolic and systolic left ventricular function over the long term. However, the hemodynamic changes immediately after valve implantation are so far poorly understood. Within this pilot study, we performed an invasive pressure volume loop analysis to describe the early hemodynamic changes after transcatheter aortic valve implantation (TAVI) with self-expandable prostheses. Invasive left ventricular pressure volume loop analysis was performed in 8 patients with aortic stenosis (mean 81.3 years) prior and immediately after transfemoral TAVI with a self-expandable valve system (St. Jude Medical Portico Valve). Parameters for global hemodynamics, afterload, contractility and the interaction of the cardiovascular system were analyzed. Left ventricular ejection fraction, (53.9% vs. 44.8%, p = 0.018), preload recruitable stroke work (68.5 vs. 44.8 mmHg, p = 0.012) and end-systolic elastance (3.55 vs. 2.17, p = 0.036) both marker for myocardial contractility declined significantly compared to baseline. As sign of impaired diastolic function, TAU, a preload-independent measure of isovolumic relaxation (37.3 vs. 41.8 ms, p = 0.018) and end-diastolic pressure (13.1 vs. 16.4 mmHg, p = 0.015) raised after valve implantation. Contrarily, a smaller ratio of end-systolic to arterial elastance (ventricular-arterial coupling) indicates an improvement of global cardiovascular energy efficiency (1.40 vs. 0.97 p = 0.036). Arterial elastance had a strong correlation with the number of conducted rapid ventricular pacings (Pearson correlation coefficient, r = 0.772, p = 0.025). Invasive left ventricular pressure volume loop analysis revealed impaired systolic and diastolic function in the early phase after TAVI with self-expandable valve for the treatment of severe aortic stenosis. Contrarily, we found indications for early improvement of global cardiovascular energy efficiency.
Background: Rates of permanent pacemaker implantation (PPI) have been low using the self‐expanding ACURATE neo device, but data regarding risk factors of PPI for this specific device are scarce.
Methods: The study cohort consisted of patients (n = 1000) with severe aortic stenosis undergoing transfemoral transcatheter aortic valve implantation (TAVI) using the ACURATE neo prosthesis in our center between May 2012 and December 2019. For the present analysis, we excluded patients with previous permanent pacemaker (n = 110), high‐grade AV block prior to TAVI (n = 3), and patients requiring conversion to surgical valve replacement (n = 4) or the implantation of a second prosthesis as valve‐in‐valve (n = 15). Preexisting conduction abnormalities were determined, and the implantation depth of the prosthesis was measured on final angiography. Differences across quartiles based on the original consecutive cohort were analyzed with respect to implantation depth and PPI rate. Predictors of PPI were identified using logistic regression.
Results: The PPI rate was 10%. Preexisting AV block I°, right bundle branch block (RBBB), and the implantation depth were independent predictors of PPI. Across quartiles, the implantation depth differed significantly with lowest values in the last quartile, whereas differences of PPI rates across quartiles were not statistically significant, but showed a notable decrease in the last quartile.
Conclusion: Preexisting RBBB, AV block I°, and low implantation depth were independent predictors of PPI following TAVI using the ACURATE neo device. Instead of deliberately aiming at a high position, avoidance of a low implantation depth may represent a reasonable compromise to reduce the rate of PPI without increasing the risk of malpositioning.
Aims: Systemic inflammatory response, identified by increased total leucocyte counts, was shown to be a strong predictor of mortality after transcatheter aortic valve implantation (TAVI). Yet the mechanisms of inflammation-associated poor outcome after TAVI are unclear. Therefore, the present study aimed at investigating individual inflammatory signatures and functional heterogeneity of circulating myeloid and T-lymphocyte subsets and their impact on 1 year survival in a single-centre cohort of patients with severe aortic stenosis undergoing TAVI. Methods and results: One hundred twenty-nine consecutive patients with severe symptomatic aortic stenosis admitted for transfemoral TAVI were included. Blood samples were obtained at baseline, immediately after, and 24 h and 3 days after TAVI, and these were analysed for inflammatory and cardiac biomarkers. Myeloid and T-lymphocyte subsets were measured using flow cytometry. The inflammatory parameters were first analysed as continuous variables; and in case of association with outcome and area under receiver operating characteristic (ROC) curve (AUC) ≥ 0.6, the values were dichotomized using optimal cut-off points. Several baseline inflammatory parameters, including high-sensitivity C-reactive protein (hsCRP; HR = 1.37, 95% CI: 1.15–1.63; P < 0.0001) and IL-6 (HR = 1.02, 95% CI: 1.01–1.03; P = 0.003), lower counts of Th2 (HR = 0.95, 95% CI: 0.91–0.99; P = 0.009), and increased percentages of Th17 cells (HR = 1.19, 95% CI: 1.02–1.38; P = 0.024) were associated with 12 month all-cause mortality. Among postprocedural parameters, only increased post-TAVI counts of non-classical monocytes immediately after TAVI were predictive of outcome (HR = 1.03, 95% CI: 1.01–1.05; P = 0.003). The occurrence of SIRS criteria within 48 h post-TAVI showed no significant association with 12 month mortality (HR = 0.57, 95% CI: 0.13–2.43, P = 0.45). In multivariate analysis of discrete or dichotomized clinical and inflammatory variables, the presence of diabetes mellitus (HR = 3.50; 95% CI: 1.42–8.62; P = 0.006), low left ventricular (LV) ejection fraction (HR = 3.16; 95% CI: 1.35–7.39; P = 0.008), increased baseline hsCRP (HR = 5.22; 95% CI: 2.09–13.01; P < 0.0001), and low baseline Th2 cell counts (HR = 8.83; 95% CI: 3.02–25.80) were significant predictors of death. The prognostic value of the linear prediction score calculated of these parameters was superior to the Society of Thoracic Surgeons score (AUC: 0.88; 95% CI: 0.78–0.99 vs. 0.75; 95% CI: 0.64–0.86, respectively; P = 0.036). Finally, when analysing LV remodelling outcomes, ROC curve analysis revealed that low numbers of Tregs (P = 0.017; AUC: 0.69) and increased Th17/Treg ratio (P = 0.012; AUC: 0.70) were predictive of adverse remodelling after TAVI. Conclusions: Our findings demonstrate an association of specific pre-existing inflammatory phenotypes with increased mortality and adverse LV remodelling after TAVI. Distinct monocyte and T-cell signatures might provide additive biomarkers to improve pre-procedural risk stratification in patients referred to TAVI for severe aortic stenosis.
Background and Objectives: We tested if a novel combination of predictors could improve the accuracy of outcome prediction after transfemoral transcatheter aortic valve implantation (TAVI). Materials and Methods: This prospective study recruited 169 participants (49% female; median age 81 years). The primary endpoint was midterm mortality; secondary endpoints were acute Valve Academic Research Consortium (VARC)-3 complication rate and post-TAVI in-hospital length of stay (LoS). EuroSCORE II (ESII), comorbidities (e.g., coronary artery disease), eGFR (estimated glomerular filtration rate; based on cystatin C), hemoglobin, creatinine, N-Terminal pro-Brain Natriuretic Peptide (NTproBNP) levels and patient-reported outcome measures (PROMs, namely EuroQol-5-Dimension-5-Levels, EQ5D5L; Kansas City Cardiomyopathy Questionnaire, KCCQ; clinical frailty scale, CFS) at baseline were tested as predictors. Regression (uni- and multi-variate Cox; linear; binary logistic) and receiver operating characteristic (ROC)-curve analysis were applied. Results: Within a median follow-up of 439 (318–585) days, 12 participants died (7.1%). Independent predictors of mortality using multivariate Cox regression were baseline eGFR (p = 0.001) and KCCQ (p = 0.037). Based on these predictors, a Linear Prediction Score (LPS1) was calculated. The LPS1-area under the curve (AUC)-value (0.761) was significantly higher than the ESII-AUC value (0.597; p = 0.035). Independent predictors for LoS > 6 days (the median LoS) were eGFR (p = 0.028), NTproBNP (p = 0.034), and EQ5D5L values (p = 0.002); a respective calculated LPS2 provided an AUC value of 0.677 (p < 0.001). Eighty participants (47.3%) experienced complications. Male sex predicted complications only in the univariate analysis. Conclusions: The combination of KCCQ and eGFR can better predict midterm mortality than ES II alone. Combining eGFR, NTproBNP, and EQ5D5L can reliably predict LoS after TAVI. This novel method improves personalized TAVI risk stratification and hence may help reduce post-TAVI risk.
Langzeitüberleben und Mortalitätsprädiktoren nach perkutanem
kathetergestütztem Aortenklappenersatz
(2022)
Ziel dieser Studie war die Evaluation von Patienten, die eine transfemorale oder eine transapikale TAVI erhalten haben, in Bezug auf ihre Mortalitätsprädiktoren und ihre Langzeit-Mortalität.
Methoden: Untersucht wurden Patienten mit einer minimalen FU-Zeit von sechs Jahren, welche im Zeitraum von 2006 – 2014 eine TAVI im Herzkatheterlabor des Universitätsklinikums in Frankfurt erhalten haben. Das Patientenkollektiv wurde basierend auf dem Zugangsweg (transfemoral oder transapikal) analysiert.
Ergebnisse: Insgesamt wurden 679 Patienten in die Studie eingeschlossen. 408 Patienten (59,82 %) bekamen eine transfemorale TAVI und 271 Patienten (39,74 %) bekamen eine transapikale TAVI. Der durchschnittliche STS-Score betrug in der transfemoralen Gruppe 4,21 ± 2,4 % und in der transapikalen Gruppe 4,19 ± 2,7 %. Die Mortalität war nach 30 Tagen (15,8 % transapikal versus 8,2 % transfemoral, p = 0,00) sowie im Langzeit-FU (79,5 % transapikal versus 68,3 % transfemoral, p = 0,00) signifikant höher in der transapikalen Gruppe. Viele postinterventionelle Komplikationen waren häufiger in der transfemoralen Gruppe. Postinterventionelle Schrittmacherimplantationen (15,7 % versus 4,1 %, p = 0,00), große und kleine vaskuläre Komplikationen (5,1 % versus 1,1 %, p = 0,01) sowie große und kleine zerebrovaskuläre Insulte (31,8 % versus 9,1 %, p = 0,00) kamen in der transfemoralen Gruppe signifikant häufiger vor. Allerdings war der transfemorale Zugangsweg mit einer besseren Überlebensrate assoziiert (Log Rank Test p = 0,01 und HR 1,33 (1,04 – 1,71), p = 0,03). Patienten mit einem hohen STS-Score (HR 1,09 (1,03 – 1,15), p = 0,00), einem vorbestehenden Diabetes Mellitus (HR 0,75 (0,58 – 0,97), p = 0,03) sowie großen Gefäßkomplikationen (HR 0,60 (0,37 – 0,99), p = 0,04) korrelieren mit einem schlechteren Langzeit-Überleben.
Zusammenfassung: Für den kathetergestützten Aortenklappenersatz weisen beide Zugangswege spezifische Risiken auf, daher sollte die individuell beste Variante für jeden Patienten ausgewählt werden.
Background: Cerebral oxygen saturation (ScO2) can be measured non-invasively by near-infrared spectroscopy (NIRS) and correlates with cerebral perfusion. We investigated cerebral saturation during transfemoral transcatheter aortic valve implantation (TAVI) and its impact on outcome.
Methods and results: Cerebral oxygenation was measured continuously by NIRS in 173 analgo-sedated patients during transfemoral TAVI (female 47%, mean age 81 years) with self-expanding (39%) and balloon-expanding valves (61%). We investigated the periprocedural dynamics of cerebral oxygenation. Mean ScO2 at baseline without oxygen supply was 60%. During rapid ventricular pacing, ScO2 dropped significantly (before 64% vs. after 55%, p < 0.001). ScO2 at baseline correlated positively with baseline left-ventricular ejection fraction (0.230, p < 0.006) and hemoglobin (0.327, p < 0.001), and inversely with EuroSCORE-II ( − 0.285, p < 0.001) and length of in-hospital stay ( − 0.229, p < 0.01). Patients with ScO2 < 56% despite oxygen supply at baseline had impaired 1 year survival (log-rank test p < 0.01) and prolonged in-hospital stay (p = 0.03). Furthermore, baseline ScO2 was found to be a predictor for 1 year survival independent of age and sex (multivariable adjusted Cox regression, p = 0.020, hazard ratio (HR 0.94, 95% CI 0.90–0.99) and independent of overall perioperative risk estimated by EuroSCORE-II and hemoglobin (p = 0.03, HR 0.95, 95% CI 0.91–0.99).
Conclusions: Low baseline ScO2 not responding to oxygen supply might act as a surrogate for impaired cardiopulmonary function and is associated with worse 1 year survival and prolonged in-hospital stay after transfemoral TAVI. ScO2 monitoring is an easy to implement diagnostic tool to screen patients at risk with a potential preserved recovery and worse outcome after TAVI.
Background: The aim of this study was to identify pre-operative parameters able to predict length of stay (LoS) based on clinical data and patient-reported outcome measures (PROMs) from a scorecard database in patients with significant aortic stenosis who underwent TAVI (transfemoral aortic valve implantation). Methods: 302 participants (51.7% males, age range 78.2–84.2 years.) were prospectively recruited. After computing the median LoS value (=6 days, range = 5–8 days), we implemented a decision tree algorithm by setting dichotomized values at median LoS as the dependent variable and assessed baseline clinical variables and PROMs (Clinical Frailty Scale (CFS), EuroQol-5 Dimension-5 Levels (EQ-5D) and Kansas City Cardiomyopathy Questionnaire (KCCQ)) as potential predictors. Results: Among clinical parameters, only peripheral arterial disease (p = 0.029, HR = 1.826) and glomerular filtration rate (GFR, cut-off < 33 mL/min/1.73 m2, p = 0.003, HR = 2.252) were predictive of LoS. Additionally, two PROMs (CFS; cut-off = 3, p < 0.001, HR = 1.324 and KCCQ; cut-off = 30, p = 0.003, HR = 2.274) were strong predictors. Further, a risk score for LoS (RS_LoS) was calculated based on these predictors. Patients with RS_LoS = 0 had a median LoS of 5 days; patients RS_LoS ≥ 3 had a median LoS of 8 days. Conclusions: based on the pre-operative values of the above four predictors, a personalized prediction of LoS after TAVI can be achieved.