Refine
Document Type
- Article (8) (remove)
Language
- English (8)
Has Fulltext
- yes (8)
Is part of the Bibliography
- no (8)
Keywords
- 4-ROD RFQ (1)
- Fringe field (1)
- Gap field (1)
- Ladder-RFQ (1)
- RFQ (1)
- cyclotron (1)
- injection (1)
- rfq (1)
- simulation (1)
- target (1)
Institute
- Physik (8)
The RFQ direct injection project (RFQ-DIP) for the neutrino physics experiment IsoDAR aims at an efficient injection of a high-current H²⁺ beam into the dedicated 60 MeV driver cyclotron. Therefore, it is intended to use a compact 32.8 MHz RFQ structure of the split-coaxial type as a pre-buncher. To determine the thermal elongation of the 1.4 m long electrode rods as well as the thermal frequency detuning of the RF structure at a maximum nominal power load of 3.6 kW, an extensive thermal and structural mechanical analysis using COMSOL Multiphysics was conducted. The water heating along the cooling channels as well as the properties of heat transfer from the copper structure to the cooling water were taken into account, which required CFD simulations of the cooling water flow in the turbulent regime. Here we present the methods and results of the sophisticated thermal and structural mechanical simulations using COMSOL and provide a comparison to more simplistic simulations conducted with CST Studio Suite.
In case of 4-Rod-type RFQ’s the quadrupole electrodes are excited by a series of coupled RF oscillators. As the contact planes between both electrode pairs differ, there remains an oscillating electric potential along the beam axis. This results in remarkably high longitudinal field components between the electrode ends and the RFQ tank end walls. In contrast, the electrodes of a 4-Vane RFQ are equally charged to ±|V0∕2| and only feature a quadrupole on-axis field. The entrance gap fields were investigated to serve as a longitudinal prebuncher instead of causing additional longitudinal emittance growth. The effects of the entrance gap field have been validated in beam dynamics simulations. The exit fields have to be taken into consideration for a calculation of the exact RFQ output energy.
Motivated by the necessary replacement of the GSI UNILAC poststripper linac, a compact and efficient linac design based on IH-type cavities has been developed. Using KONUS beam dynamics, it was possible to design a linac consisting of only five cavities that can be operated by the existing UNILAC RF amplifier structure. The transversal focusing scheme is based on magnetic quadrupole triplet lenses. The optimized design provides full transmission and low emittance growth for the design current of 15 emA U28+, accelerating the beam from 1.4 MeV/u to 11.4 MeV/u. Extensive error studies were performed to define tolerances and verify the stability of the design with respect to misalignment and injection parameters. The design provides a compact and cost effective alternative to a new Alvarez linac. With a total length of just 22.8 meters it will leave room for future energy upgrades in the UNILAC tunnel.
The crossbar H-mode (CH) cavity is an accelerating structure operated in the H21(0) mode. The robustness of the crossbar geometry allows one to realize room temperature as well as superconducting linac cavities. The shunt impedance characteristics of this structure are attractive to develop proton and heavy ion linacs in the low and medium beta range. A first room temperature eight-cell prototype has proven the feasibility of the crossbar design in terms of mechanical construction, copper plating, and cooling. An innovative rf coupling concept has been developed where two CH cavities are connected by a two gap E010-mode resonator which, at the same time, provides transverse focusing by a quadrupole triplet. The concept has been applied in the design of the new FAIR proton linac and a scaled model of the second cavity of this injector has been built and tested too. The full scale prototype is now under construction at the University of Frankfurt. In this paper, the room temperature CH cavity development as well as the general layout of the FAIR proton injector (70 MeV, 325 MHz, 70 mA) is presented and discussed.
The development of a non- destructive measurement method for ion beam parameters has been treated in various projects. Although results are promising, the high complexity of beam dynamics has made it impossible to implement a real time process control up to now. In this paper we will propose analysing methods based on the dynamics of Cellular Nonlinear Networks (CNN) that can be implemented on pixel parallel CNN based architectures and yield satisfying results even at low resolutions.
The crossbar-H-mode (CH) structure is the first superconducting multicell drift tube cavity for the low and medium energy range operated in the H21 mode. Because of the large energy gain per cavity, which leads to high real estate gradients, it is an excellent candidate for the efficient acceleration in high power proton and ion accelerators with fixed velocity profile. A prototype cavity has been developed and tested successfully with a gradient of 7MV/m. A few new superconducting CH cavities with improved geometries for different high power applications are under development at present. One cavity (f=325 MHz, β=0.16, seven cells) is currently under construction and studied with respect to a possible upgrade option for the GSI UNILAC. Another cavity (f=217 MHz, β=0.059, 15 cells) is designed for a cw operated energy variable heavy ion linac application. Furthermore, the EUROTRANS project (European research program for the transmutation of high level nuclear waste in an accelerator driven system, 600 MeV protons, 352 MHz) is one of many possible applications for this kind of superconducting rf cavity. In this context a layout of the 17 MeV EUROTRANS injector containing four superconducting CH cavities was proposed by the Institute for Applied Physics (IAP) Frankfurt. The status of the cavity development related to the EUROTRANS injector is presented.
EUROTRANS is a European research program for the transmutation of high level nuclear waste in an accelerator-driven system (ADS). As proposed, the driver linac needs to deliver a 2.5–4 mA, 600 MeV continuous-wave (CW) proton beam and later a 20 mA, 800 MeV one to the spallation target in the prototype-scale and industrial-scale demonstration phases, respectively. This paper is focusing on the conceptual studies performed with respect to the 17 MeV injector. First, the special beam dynamics strategies and methods, which have been developed and applied to design a current-variable injector up to 30 mA for allowing an easy upgrade without additional R&D costs, will be introduced. Then the error study made for evaluating the tolerance limits of the designed injector will be presented as well.
Superconducting, energy variable heavy ion linac with constant
β, multicell cavities of CH-type
(2009)
An energy variable ion linac consisting of multigap, constant-β cavities was developed. The effect of phase sliding, unavoidable in any constant-β section, is leading to a coherent rf phase motion, which fits well to the H-type structures with their long π-mode sections and separated lenses. The exact periodicity of the cell lengths within each cavity results in technical advantages, such as higher calculation accuracy when only one single period can be simulated, simpler manufacturing, and tuning. This is most important in the case of superconducting cavities. By using this concept, an improved design for a 217 MHz cw superconducting heavy ion linac with energy variation has been worked out. The small output energy spread of ± 3 AkeV is provided over the whole range of energy variation from 3.5 to 7.3 AMeV. These capabilities would allow for a competitive research in the field of radiochemistry and for a production of super heavy elements (SHE), especially. A first 19-cell cavity of that type was designed, built, and rf tested successfully at the Institute for Applied Physics (IAP) Frankfurt. A 325.224 MHz, seven-cell cavity with constant β = 0.16 is under development and will be operated in a frequency controlled mode. It will be equipped with a power coupler and beam tests with Unilac beams at GSI are foreseen.