Two tetrahydroisoquinoline alkaloids were extracted from the alkaloid fraction of a methanol extract of the seeds of Calycotome Villosa Subsp. intermedia. Their structures were established as (R)-1-hydroxymethyl-7-8-dimethoxy-1,2,3,4-tetrahydro- isoquinoline (1) and (S)-7-hydroxymethyl-2-3-dimethoxy-7,8,9,10-tetrahydroisoquinoline chloride (2) by spectroscopic techniques and X-ray diffraction analysis.
Motiviert durch aktuelle atomphysikalische Fragestellungen zur Struktur und Dynamik der Materie im Bereich hochgeladener Schwerionen entstand der Bedarf zur Weiterentwicklung bestehender und zur Entwicklung neuartiger ortsauflösender Detektorsysteme. Die Untersuchung der Struktur ist hauptsächlich durch die hochauflösende spektroskopische Vermessung einzelner Energieniveaus der atomaren Hülle bestimmt und liefert grundlegende Einblicke in den atomaren Aufbau. Dabei stellen diese Resultate gerade bei schweren hochgeladenen Ionen eine exzellente Testmöglichkeit der QED in extrem starken Feldern dar. Die Dynamik der Materie zeigt sich in der Teilchendynamik (hier der Atomhülle) in extrem starken und extrem kurzen elektromagnetischen Feldern, wie sie bei Ion-Atom-Stößen auftreten. Beobachtet werden können hier vor allem Teilchen und Photonen-Polarisationsphänomene. Solche Polarisationseffekte sind jedoch nicht auf das Gebiet der atomaren Hülle beschränkt. Als ein Beispiel sei die Untersuchung laserbeschleunigter Teilchen genannt. Hier kann die Polarimetrie von Röntgenstrahlung, die durch Thomson-Streuung optischer Photonen an den zuvor auf relativistische Geschwindigkeiten beschleunigten Teilchen erzeugt wird, Aufschluß über die Natur des Beschleunigungsprozesses geben. Einblick in die lineare Polarisation der Röntgenphotonen im für unsere Arbeit interessanten Energiebereich von einigen 10 keV bis einigen 100 keV können mit Compton-Polarimetern gewonnen werden. Kommerziell sind Detektorsysteme, die eine ausreichende Granularität in Kombination mit hinreichender Detektordicke besitzen, um hohe Nachweiseffizienzen zu erreichen, jedoch nicht verfügbar. Im Rahmen der vorgelegten Arbeit, die sich mit Techniken der hochaufgelösten Röntgenspektroskopie und der Röntgenpolarimetrie an hochgeladenen Schwerionen befasst, wurden vielfältige Arbeiten an und mit orts-, zeit- und energieauflösenden planaren Ge(i)-Detektorsystemen durchgeführt. Wesentliches Ziel der Arbeit war es, ein zweidimensional ortsauflösendes planares Halbleiterdetektorsystem, das für den Einsatz im Kristallspektrometer FOCAL und als Compton-Polarimeter angepasst ist, bereitzustellen. Hierzu wurde ein 2D-µ-Streifendetektorsystem aufgebaut, das eine Ortsauflösung von 250µm, bzw. 1167µm in orthogonaler Richtung, bei einer Detektordicke von 11mm und eine Energieauflösung von etwa 2 keV für jeden einzelnen Streifen bei 60 keV Photonenenergie gewährleistet. Durch Messungen an der Synchrotronquelle ESRF, Grenoble (Frankreich), wurde die Eignung des Systems als bildgebendes Element im FOCAL Kristallspektrometer bei einer Photonenenergie von 60 keV und als Compton-Polarimeter bei einer Photonenenergie von 210 keV untersucht. Der große Vorteil in FOCAL ein ortsauflösendes Detektorsystem einzusetzen, liegt darin, dass alle interessanten Beugungswinkel simultan beobachtet werden können. Im herkömmlichen Ansatz würde man mit einer einfachen Diode und einem Kollimator den Bereich abfahren. Wegen der geringen Ereignisrate und dem hohen Untergrund ist dies jedoch nicht praktikabel. Herkömmliche Systeme wie CCD oder Gasdetektoren haben nicht die nötige Effizienz oder eine zu hohe Dunkelrate. Zur Untersuchung der für FOCAL wichtigen Eigenschaften wurden mehrere Positionen auf dem Detektor bei niedriger Energie mit einem fein kollimierten Photonenstrahl (50 x 50 µm2) gescannt. Neben der guten Energieauflösung des Detektorsystems von durchschnittlich 2.2 keV bei 60 keV, zeigen die Ergebnisse das homogene Verhalten der Detektoreffizienz, welche essentiell für den spektographischen Einsatz in FOCAL ist. Es konnten keine Hinweise auf messbare Ladungsverluste im Bereich des aktiven Detektorvolumens festgestellt werden. Ebenso konnte die Multiplizität (Anzahl der Streifen einer Detektorseite, die auf ein Ereignis reagieren), mit der ein Photon nachgewiesen wird, eindeutig mit der Strukturierung der Kontakte auf der Kristalloberfläche in Verbindung gebracht werden. Es stellte sich heraus, dass die Ereignisse der Multiplizität zwei dazu verwendet werden können um Ortsauflösungen deutlich unterhalb einer Streifenbreite zu erreichen. Diese Methode kann jedoch nur auf eine größere Anzahl von Ereignissen angewendet werden, nicht jedoch auf einzelne Ereignisse. Um das 2D-Ge(i)-µ-Streifendetektorsystem auf seine Eignung als Compton-Polarimeter zu testen, wurden Daten mit einem nahezu vollständig linear polarisierten Photonenstrahl (98% linear polarisiert) bei einer Energie von 210 keV aufgenommen. Die Daten zeigen die erwartete Dipol-ähnliche Asymmetrie im Ortsbild und dienen als Kalibrationsgrundlage zur Interpretation zukünftiger Experimente zur Polarimetrie in diesem Energiebereich. Parallel hierzu wurde an Simulationsprogrammen auf Basis der etablierten Monte Carlo Software EGS4 gearbeitet. Hiermit wurden Vorhersagen bezüglich des Nachweisverhaltens des Detektors auf linear polarisierte Röntgenstahlung gemacht. Ferner wurde für ein 4x4-Pixel-Polarimeter, das bei der ersten Bestimmung der linearen Polarisation der K-REC Strahlung von U92+ am Speichering ESR der GSI eingesetzt wurde, im Rahmen der Datenanalyse mit den auf EGS4-basierenden Programmen die Detektoreffizienz für linear polarisierte Strahlung einer bestimmten Energie simuliert. Mit diesen Simulationsergebnissen konnten die selbstentwickelten Methoden zur Korrektur der Nachweiswahrscheinlichkeit eines Compton-Ereignisses als Funktion des Wechselwirkungspunkts innerhalb des Detektorkristalls und der Energie erfolgreich verifiziert werden. Die detektorbezogenen Resultate dieser Arbeit fanden ihre erste Anwendung in der FOCAL-Spektrometer Strahlzeit 2006, deren genaue Beschreibung jedoch über den Umfang dieser Arbeit hinausgeht. Ebenso flossen die Erfahrungen, die mit den Detektorsystemen, im speziellen dem 2D-Ge(i)-µ-Streifendetektor, gemacht wurden in die Realisierung eines Si(Li)-Detektors mit 32+32 Streifen zur Compton-Polarimetrie bei niedrigeren Energien (ab 60 keV) ein, der gegenwärtig in ersten Experimenten am ESR eingesetzt wird.
Water-filtered infrared-A (wIRA) can act as a penetration enhancer for topically applied substances
(2008)
Background: Water-filtered infrared-A (wIRA) irradiation has been shown to enhance penetration of clinically used topically applied substances in humans through investigation of functional effects of penetrated substances like vasoconstriction by cortisone.
Aim of the study: Investigation of the influence of wIRA irradiation on the dermatopharmacokinetics of topically applied substances by use of optical methods, especially to localize penetrating substances, in a prospective randomised controlled study in humans.
Methods: The penetration profiles of the hydrophilic dye fluorescein and the lipophilic dye curcumin in separate standard water-in-oil emulsions were determined on the inner forearm of test persons by tape stripping in combination with spectroscopic measurements. Additionally, the penetration was investigated in vivo by laser scanning microscopy. Transepidermal water loss, hydration of the epidermis, and surface temperature were determined. Three different procedures (modes A, B, C) were used in a randomised order on three separate days of investigation in each of 12 test persons. In mode A, the two dyes were applied on different skin areas without water-filtered infrared-A (wIRA) irradiation. In mode B, the skin surface was irradiated with wIRA over 30 min before application of the two dyes (Hydrosun® radiator type 501, 10 mm water cuvette, orange filter OG590, water-filtered spectrum: 590–1400 nm with dominant amount of wIRA). In mode C, the two dyes were applied and immediately afterwards the skin was irradiated with wIRA over 30 min. In all modes, tape stripping started 30 min after application of the formulations. Main variable of interest was the ratio of the amount of the dye in the deeper (second) 10% of the stratum corneum to the amount of the dye in the upper 10% of the stratum corneum.
Results: The penetration profiles of the hydrophilic fluorescein showed in case of pretreatment or treatment with wIRA (modes B and C) an increased penetration depth compared to the non-irradiated skin (mode A): The ratio of the amount of the dye in the deeper (second) 10% of the stratum corneum to the amount of the dye in the upper 10% of the stratum corneum showed medians and interquartile ranges for mode A of 0.017 (0.007/0.050), for mode B of 0.084 (0.021/0.106), for mode C of 0.104 (0.069/0.192) (difference between modes: p=0.0112, significant; comparison mode A with mode C: p<0.01, significant). In contrast to fluorescein, the lipophilic curcumin showed no differences in the penetration kinetics, in reference to whether the skin was irradiated with wIRA or not. These effects were confirmed by laser scanning microscopy. Water-filtered infrared-A irradiation increased the hydration of the stratum corneum: transepidermal water loss rose from approximately 8.8 g m-2 h-1 before wIRA irradiation to 14.2 g m-2 h-1 after wIRA irradiation and skin hydration rose from 67 to 87 relative units. Skin surface temperature increased from 32.8°C before wIRA to 36.4°C after wIRA irradiation.
Discussion: The better penetration of the hydrophilic dye fluorescein after or during skin irradiation (modes B and C) can be explained by increased hydration of the stratum corneum by irradiation with wIRA.
Conclusions: As most topically applied substances for the treatment of patients are mainly hydrophilic, wIRA can be used to improve the penetration of substances before or after application of substances – in the first case even of thermolabile substances – with a broad clinical relevance as a contact free alternative to an occlusive dressing.
Die Fluoreszenz der organischen Verbindung ''Pigment Yellow 101'' wurde mittels zeitaufgelöster Anreg-Abtast-Spektroskopie im sichtbaren Spektralbereich untersucht. P.Y. 101 und ein Derivat mit zusätzlichen Methylgruppen an den Azin-Kohlenstoffatomen, wurden mit zwei Derivaten verglichen, die keine Hydroxygruppen tragen und nicht fluoreszieren. Es konnte gezeigt werden, dass die Fluoreszenz bei diesen Verbindungen eine intrinsische Eigenschaft ist, die von der Reihenfolge der angeregten Zustände bestimmt wird. Bei Derivaten mit Hydroxygruppe entspricht der niedrigste angeregte Zustand einem pp*-Übergang, welcher hauptsächlich durch Fluoreszenz zurück in den Grundzustand gelangt. Bei den Verbindungen ohne Hydroxygruppe fehlt die stabilisierende Wasserstoffbrücke, die zur Absenkung des entsprechenden Zustands führt, so dass bei diesen Derivaten der unterste angeregte Zustand einem np*-Übergang entspricht, der optisch verboten ist und somit nicht direkt populiert wird. Bei der Anregung wird ein höher angeregter Zustand bevölkert, der in den niedrigsten angeregten Zustand relaxiert, welcher über eine konische Durchschneidung schnell und strahlungsfrei erreicht werden kann. Der niedrigste angeregte Zustand schneidet seinerseits den Grundzustand, so dass auch die Repopulierung des Ausgangszustands schnell, effizient und strahlungslos abläuft. Eine ganz andere Art der Photochemie wird bei Azobenzol (AB) und AB-Derivaten beobachtet. Durch Isomerisierung um die N-N-Doppelbindung wird ein Photoprodukt gebildet, das cis-Isomer. Die Quantenausbeute der Isomerisierung ist dabei abhängig davon, welcher elektronische Übergang angeregt wurde. Substituenten am AB üben unterschiedlichen Einfluss auf die elektronischen Eigenschaften aus: Elektronegative Gruppen in meta-Position zur Diazobrücke verändern die Lage der Absorptionsbanden kaum, ebensowenig die Rate der thermischen Rückisomerisierung und auch die Dynamik nach Photoanregung zeigt keine signifikanten Unterschiede in Abhängigkeit vom Substituenten und kann in Analogie an unsubstituiertes AB interpretiert werden. Nach Anregung des np*-Übergangs zerfällt der angeregte Zustand biexponentiell. Die Anregung des pp*-Übergangs, dem optisch erlaubten Übergang, führt zur Population des zweiten angeregten Zustands. Entlang einer konischen Durchschneidung wird schnell und effizient der erste angeregte Zustand populiert. Dieser Prozess zeigt sich bei den zeitaufgelösten Messungen in einer schnellen Zerfallszeit, die nur wenige hundert Femtosekunden beträgt. Die nun folgenden Prozesse finden im ersten angeregten Zustand statt und sind vergleichbar mit den Prozessen nach np*-Anregung. Der Hauptunterschied zwischen den beiden Dynamiken im S1-Zustand ist die Ausgangsgeometrie, mit der die Moleküle diesen Zustand populieren (Franck-Condon-Bereich bei direkter Anregung, bzw. eine große Bandbreite an Geometrien nach dem S2-S1-Übergang), sowie die Schwingungsenergie die das System jeweils besitzt. Auch nach ursprünglicher S2-Anregung können zwei Zerfallszeiten dem ersten angeregten Zustand zugeordnet werden, die analog der direkten Population als Geometrieänderung in Richtung des Potentialminimums und Isomerisierung bzw. Rückkehr in den Grundzustand interpretiert werden und in der Größenordnung von einer bzw. fünf Pikosekunden liegen. Die Modifizierung von Peptiden mit Azobenzol stellt einen Weg dar, zeitlich synchronisiert, eine Störung in der Struktur zu induzieren. Dieses Konzept wurde bereits erfolgreich zur Untersuchung der Faltung zyklischer Peptide eingesetzt. Modifizierte Kollagenstränge sind eine Erweiterung dieses Prinzips, da sie eine Möglichkeit darstellen, die Tertiärstruktur eines Peptids zu adressieren. Für das vorliegende Azokollagen konnte gezeigt werden, dass die gewählte Aminosäuresequenz auch nach Anbringen der Azobenzolklammer zu gefaltetem Kollagen führt, welches thermodynamisch stabil ist. Der Schmelzpunkt der Tripelhelix liegt unter den gewählten Bedingungen bei 55°C. Die Isomerisierung des Azobenzols induziert eine Störung der Tertiärstruktur, die zur teilweisen Entfaltung der Tripelhelix führt, was ein reversibler Prozess ist. Eine vollständige Entfaltung findet erst bei Temperaturen oberhalb des Schmelzpunkts statt. Zeitaufgelöste Messungen im sichtbaren Spektralbereich zeigten, dass die Schalterdynamik durch Anbringung an das Peptid nicht signifikant im Vergleich zum reinen AB-Schalter verändert wird.
Brain metastases are the most common intracranial tumor in adults and are associated with poor patient prognosis and median survival of only a few months. Treatment options for brain metastasis patients remain limited and largely depend on surgical resection, radio- and/or chemotherapy. The development and pre-clinical testing of novel therapeutic strategies require reliable experimental models and diagnostic tools that closely mimic technologies that are used in the clinic and reflect histopathological and biochemical changes that distinguish tumor progression from therapeutic response. In this study, we sought to test the applicability of magnetic resonance (MR) spectroscopy in combination with MR imaging to closely monitor therapeutic efficacy in a breast-to-brain metastasis model. Given the importance of radiotherapy as the standard of care for the majority of brain metastases patients, we chose to monitor the post-irradiation response by magnetic resonance spectroscopy (MRS) in combination with MR imaging (MRI) using a 7 Tesla small animal scanner. Radiation was applied as whole brain radiotherapy (WBRT) using the image-guided Small Animal Radiation Research Platform (SARRP). Here we describe alterations in different metabolites, including creatine and N-acetylaspartate, that are characteristic for brain metastases progression and lactate, which indicates hypoxia, while choline levels remained stable. Radiotherapy resulted in normalization of metabolite levels indicating tumor stasis or regression in response to treatment. Our data indicate that the use of MR spectroscopy in addition to MRI represents a valuable tool to closely monitor not only volumetrical but also metabolic changes during tumor progression and to evaluate therapeutic efficacy of intervention strategies. Adapting the analytical technology in brain metastasis models to those used in clinical settings will increase the translational significance of experimental evaluation and thus contribute to the advancement of pre-clinical assessment of novel therapeutic strategies to improve treatment options for brain metastases patients.
A single wavelength heterodyne interferometer has been set up to investigate the free electron density integrated axially along the line of sight (line density) in a theta-pinch plasma to determine its applicability as a plasma target for ion beam stripping. The maximal line density reached in this experiment was (3.57 ± 0.28) × 1018 cm−2 at 80 Pa and 20 kV. The findings demonstrate the pulsed character of the line density and its increase by raising the load voltage and the working gas pressure. Additionally, the results were compared with spectroscopic free electron density estimations, which were carried out by Hβ -line broadening and peak separation. The time behavior of the line density indicates that its peak value is delayed by about 10 μs compared to the spectroscopic results. This effect is due to the formation of an extended, magnetically compressed plasma column in the vicinity of the current maximum, although the highest volumetric free electron density is reached near the current zero crossing. Since the line density is an essential parameter in describing the stripping capabilities of the plasma target, the interferometric diagnostic is superior to a spectroscopic diagnostic, because it directly provides integrated values along the line of sight. Furthermore, the measurements of the line density in this experiment partially show nonphysical negative values, which is due to gaseous effects and residual shot vibrations.
Bicellonycha amoena (Gorham, 1880) (Coleoptera: Lampyridae) usually flies one meter above ground level over grass, water, or open areas, where males produce a simple single flash every 2–4 seconds, having their most active flashing period from mid to late dusk and early night. In addition, nothing else is known about the behavior of this species. We conducted field observations at the “Mayan Golf Club” in Guatemala Department, and Santiago Sacatepéquez, Sacatepéquez Department, Guatemala; and analyzed B. amoena flashes with a spectroscope. Fireflies displayed a lime-green bioluminescence color. The male flashing activity began ~30 minutes after sunset and lasted approximately 70 minutes. For B. amoena, the spectral composition of the flash is intermediate between those known from twilight-active fireflies and nocturnalactive fireflies.
ZooBank registration. urn:lsid:zoobank.org:pub:512FB867-8E8F-47E6-AD02-B3B13C97C25D