Aim: To evaluate the occurrence and severity of enterostomy complications in newborns suffering from different intestinal disorders.
Methods: A 10-year retrospective cohort study (2008-2017) investigated newborns that underwent enterostomy formation and reversal for different intestinal disorders. Only infants less than 28 d old at the time of enterostomy creation were included in the study (corrected age was applied in the cases of preterm neonates). The patients were divided into two groups according to their underlying diseases. Group 1 included infants suffering from necrotizing enterocolitis (NEC), whereas Group 2 included newborns diagnosed with intestinal disorders other than NEC, such as meconium obstruction, anorectal malformation, focal intestinal perforation, ileus, intestinal atresia and volvulus. The primary outcome measure was enterostomy-related morbidity. The data were analyzed statistically using Pearson’s χ2 test or Fisher’s exact test for categorical variables and the Wilcoxon-Mann-Whitney U-Test for continuous variables.
Results: In total, 76 infants met the inclusion criteria and were evaluated for enterostomy-related complications. Neither group showed significant differences regarding gender, gestational age, weight at birth or weight at enterostomy formation. Infants suffering from NEC (Group 1) were significantly older at enterostomy formation than the neonates of Group 2 [median (range), 11 (2-75) d vs 4 (1-101) d, P = 0.004)]. Significantly more ileostomies were created in Group 1 [47 (92.2%) vs 16 (64.0%), P = 0.007], whereas colostomies were performed significantly more often in Group 2 [2 (3.9%) vs 8 (32.0%), P = 0.002]. The initiation of enteral nutrition after enterostomy was significantly later in Group 1 infants than in Group 2 infants [median (range), 5 (3-13) vs 3 (1-9), P < 0.001]. The overall rate of one or more complications in patients of both groups after enterostomy formation was 80.3%, with rates of 86.3% in Group 1 and 68.0% in Group 2 (P = 0.073). Most patients suffered from two complications (23.7%). Four or more complications occurred in 21.6% of the infants in Group 1 and in 12.0% of the infants in Group 2 (P = 0.365). Following enterostomy closure, at least one complication was observed in 26.0% of the patients (30.6% in Group 1 and 16.7% in Group 2, P = 0.321). The occurrence of complications was not significantly different between neonates with NEC and infants with other intestinal disorders. 48 (65.8%) patients required no treatment or only pharmacological treatment for the complications that occurred [Clavien-Dindo-Classification (CDC) < III], while 25 (34.2%) required surgery to address the complications (CDC ≥ III). Early reversal of the enterostomy was performed significantly more often (P = 0.003) and the time to full enteral nutrition after closure was significantly longer [median (range), 7 (3-87) d vs 12 (5-93) d, P = 0.006] in infants with a CDC grading ≥ III than in infants with a CDC grading < III.
Conclusion: Complications occur in almost all infants with enterostomies. The majority of these complications are minor and do not require surgical treatment. There is a clear trend that neonates with NEC have a higher risk for developing complications than those without NEC.
Background: Incisional heia is a frequent complication of midline laparotomy. The use of mesh in hernia repair has been reported to lead to fewer recurrences compared to primary repair. However, in Ventral Hernia Working Group (VHWG) Grade 3 hernia patients, whose hernia is potentially contaminated, synthetic mesh is prone to infection. There is a strong preference for resorbable biological mesh in contaminated fields, since it is more able to resist infection, and because it is fully resorbed, the chance of a foreign body reaction is reduced. However, when not crosslinked, biological resorbable mesh products tend to degrade too quickly to facilitate native cellular ingrowth. Phasix™ Mesh is a biosynthetic mesh with both the biocompatibility and resorbability of a biological mesh and the mechanical strength of a synthetic mesh. This multi-center single-arm study aims to collect data on safety and performance of Phasix™ Mesh in Grade 3 hernia patients.
Methods: A total of 85 VHWG Grade 3 hernia patients will be treated with Phasix™ Mesh in 15 sites across Europe. The primary outcome is Surgical Site Occurrence (SSO) including hematoma, seroma, infection, dehiscence and fistula formation (requiring intervention) through 3 months. Secondary outcomes include recurrence, infection and quality of life related outcomes after 24 months. Follow-up visits will be at drain removal (if drains were not placed, then on discharge or staple removal instead) and in the 1st, 3rd, 6th, 12th, 18th and 24th month after surgery.
Conclusion: Based on evidence from this clinical study Depending on the results this clinical study will yield, Phasix™ Mesh may become a preferred treatment option in VHWG Grade 3 patients.
Trial registration: The trial was registered on March 25, 2016 on clinicaltrials.gov: NCT02720042.