Refine
Year of publication
Document Type
- Bachelor Thesis (75) (remove)
Has Fulltext
- yes (75)
Is part of the Bibliography
- no (75) (remove)
Keywords
- Beschleunigerphysik (2)
- FRANZ (2)
- Ionenstrahl (2)
- Strahldynamik (2)
- Strahlprofil (2)
- (n, gamma) Reaktionen (1)
- (n, gamma) reactions (1)
- BaF2 Detektor-Array (1)
- BaF2 detector array (1)
- Charge change (1)
- Detektor-Array (1)
- Drift Tube Linac (1)
- Emittanz (1)
- Energieauflösung (1)
- Gabor Lens (1)
- Gabor lens (1)
- Gabor-Linse (1)
- Gamma-Kaskade (1)
- Ionenbeschleuniger (1)
- Momentum Spectrometry (1)
- Neutronendetektor (1)
- Neutroneneinfang (1)
- Neutroneneinfangsquerschnitte (1)
- Neutronenstrahl (1)
- Optische Tomographie (1)
- Protonenplasmen (1)
- Protonenstrahl (1)
- RFQ (1)
- Speicherring (1)
- Strahldiagnose (1)
- Strahltransport (1)
- Teilchenbeschleuniger (1)
- Tomographie (1)
- Toroidales Magnetfeld (1)
- Wasserstoffatmosphäre (1)
- Wirkungsquerschnitt (1)
- Zeitauflösung (1)
- Zerstörungsfrei (1)
- beam dynamics (1)
- beam transport (1)
- hydrogen atmosphere (1)
- neutron capture cross-sections (1)
- neutron detector (1)
- toroidal magnetic field (1)
- toroidales Magnetfeld (1)
Institute
- Physik (75) (remove)
An der Goethe Universität in Frankfurt wird ein Konzept für ein magnetostatischen Hochstromspeicherring für Protonen- und Ionenstrahlen entwickelt und untersucht. Zur Zeit stehen dem Experiment zwei Toroidsegmente und eine Volumenionenquelle zur Verfügung. An diesem Aufbau werden Experimente mit dem Ziel die Strahldynamik zu untersuchen und die Strahldiagnose in toroidalen Magnetfeldern zu entwickeln, durchgeführt [Joshi] Für Experimente ist eine Strahldiagnose entlang der starken toroidalen Magnetfelder bis maximal 0, 6T nötig. Dabei sind die zur Verfügung stehenden Strahldiagnoseverfahren zum Einen ein Faraday-Cup und zum Anderen ein entlang des kompletten Aufbaus beweglicher Szintillatordetektor. Der Szintillatordetektor, besteht aus einem Phosphorschirm und einer Kamera, die hinter dem Schirm angebracht ist. [Nonn] Aufgrund der geschlossenen Ringgeometrie und dem Anspruch auf eine hohe Flexibilität des Detektors ist die Konstruktion eines neuen von starken Magnetfeldern unbeeinflussbaren und sehr kompakten Detektors notwendig. Ziel dieser Arbeit ist es, ein allgemeines Strahldiagnoseverfahren zu entwickeln.
Mit dieser Arbeit wurde gezeigt, wie sich Störung und Kopplung auf ein System zwei gekoppelter Resonatoren auswirkt. Das Einfahren des Tauchkolbens birgt die Möglichkeit die Eigenfrequenzen des Systems zu verändern und die Feldverteilungen anzupassen. Ein Tauchkolben auf der anderen Seite des Resonators wäre für die Anschauung der Störung praktisch gewesen, hätte jedoch keine weiteren Erkenntnisse geliefert.
Es ist möglich mit zwei verschiedenen eingekoppelten Frequenzen eine Schwebung im Resonator zu erzeugen. Dies könnte theoretisch für eine Hochfrequenzstrahlablenkung nützlich sein. Mit einer speziell auf Strahlablenkung optimierten Resonatorgeometrie gilt es dies praktisch zu überprüfen.
In dieser Arbeit wurde gezeigt, ob Simulation und Messung der realen Struktur übereinstimmen. Dazu wurde mit Hilfe der Störkörpermessmethode über die Phasenverschiebung die elektrische Feldverteilung einer IH-Struktur bestimmt (unter Variation der Tunerhöhe). Die Feldverteilung von Simulation und Messung sind im Kurvenverlauf gleich, allerdings ist die Stärke der Simulationsfelder um einen Faktor 1,1 – 1,2 größer...
Ziel dieser Arbeit war die Untersuchung eines neuen Prototypen für den Übergangsstrahlungsdetektor im zukünftigen CBM-Experiment. Da der TRD zur Untersuchung des Quark-Gluon-Plasmas im Bereich hoher Baryonendichten bei hohen Kollisionsraten besonders schnell sein muss, wurde ein Prototyp mit einem kleinen Gasvolumen ohne Driftbereich entwickelt. Die Geometrie ist jedoch mit einer Reduzierung der Stabilität der Gasverstärkung verbunden, denn das elektrische Feld in der Kammer ist bei den geringen Abständen von Verformungen des dünnen Kathodenfensters abhängig. Daher wurde eine vielversprechende, veränderte Drahtgeometrie eingeführt: zwischen den Anodendrähten wurden zusätzliche Felddrähte positioniert, um das elektrische Feld im Bereich der Gasverstärkung zu stabilisieren.
Der neue Prototyp mit alternierender Hochspanngung und mit einer Dicke von 8 mm sowie einer aktiven Fläche von 15 x 15 cm2 wurde im Labor mit einer 55Fe-Quelle getestet.
Dazu wurden Strommessungen und eine spektrale Analyse für 25 verschiedene Positionen der Quelle vor der Kammer durchgeführt, sowohl mit der neuen Kammer als auch mit einer Standardkammer als Referenz. Die mit der neuen Kammer verbundenen positiven Erwartungen konnten durchweg bestätigt werden. Sowohl für die Strom- als auch für Energiemessung konnte eine signifikante Verbesserung der Stabilität der Gasverstärkung festgestellt werden. Variationen von über 60 % über die verschiedenen Messpunkte für die Standardkammer konnten mit der Kammer mit alternierender Hochspannung auf unter 15 % reduziert werden. Auch bei einer Variation des differentiellen Drucks, der mit der Ausdehnung des Folienfensters verbunden ist, kann das elektrische Feldes mithilfe der Felddrähte stabilisiert werden. Ebenso kann eine Analyse der Energieauflösung für die mit den Prototypen aufgezeichneten Spektren den stabilisierenden Effekt bestätigen. Eine zusätzliche Verbesserung durch das Anlegen einer negativen Spannung an den Felddrähten konnte allerdings nicht beobachtet werden. Ebenso zeigten die Messungen mit einer zweiten Kammer mit asymmetrischer Geometrie, das heißt die Drahtebene wurde in Richtung der hinteren Kathode verschoben, keine weitere Stabilisierung. Messungen der an den Felddrähten influenzierten Ströme zeigen, dass diese etwa bei einem Drittel der Anodenströme liegen, wobei sie für eine Erhöhung der Felddrahtspannung ebenso wie für die Messung mit der asymmetrischen Kammer leicht ansteigen. Die Ströme an den Felddrähten sind mit der Bewegung der Ionen in der Kammer verbunden, die das elektrische Feld stören können. Durch die Einführung der Felddrähte wird sich ein Teil der Ionen zu diesen bewegen, anstelle den Weg durch die Kammer bis zu den Kathoden zurückzulegen.
Die positiven Ergebnisse für die Kammer mit alternierenden Drähten sind nun Ausgangspunkt für weitere Schritte. Größere Kammern mit einer Fläche von 60 x 60 cm2, wie sie auch im finalen Experiment eingesetzt werden, wurden bereits gebaut und in einem gemischten Elektron-Pion-Strahl am PS (Protonsynchrotron) und mit einem Bleitarget am SPS (Super-Proton Synchrotron) am CERN getestet. Dabei wurde die Dicke des Gasvolumens nochmals – auf 7 mm – reduziert, was die Schnelligkeit des Detektors weiter erhöht, allerdings auch die Stabilität der Gasverstärkung wieder auf die Probe stellt. Die Daten werden derzeit ausgewertet. Eine weitere Analyse auf Basis der Padauslese im Labor ist in Planung. Hierbei ist insbesondere die Verteilung eines Signals über die Pads (Pad-Response-Funktion) von Bedeutung, wobei diese von der Bewegung der Ionen und damit von der Geometrie des elektrischen Feldes beeinflusst wird. Die Einführung der Felddrähte spielt hier eine wesentliche Rolle; insbesondere beträgt der Drahtabständ zwischen den Andodendrähten nun 5 mm, während die Abstände bei den vorhergehenden Generationen bei 2-3 mm lagen.
Auch die Signalform ist von Interesse. Die derzeit ebenfalls in Entwicklung befindliche Ausleseelektronik und die Algorithmen zur Datenverarbeitung sind auf die bekannte Signalform eines Standardprototypen ausgerichtet. Eine veränderte Form müsste entsprechend berücksichtigt werden, um aussagekräftige Ergebnisse zu erhalten. Die Auswertungen in dieser Arbeit zeigen, dass sich die Signalform grundsätzlich nicht von der des Standardprototypen unterscheidet. Wichtig sind auch die Driftzeiten für Elektronen aus der Lawine. Sie spielen eine entscheidende Rolle für die die Schnelligkeit des Detektors. Mit der Einführung der Felddrähte liegen sie zwar zum großen Teil nach wie vor im Bereich eines Standardprototyen mit entsprechender Dicke des Gasvolumens von 8 mm bei bis zu 150 ns, jedoch folgt dann ein sehr langsamer Abfall mit Elektrondriftzeiten von bis zu 450 ns [47]. Eine Verbesserung ist durch ein kleineres Gasvolumen möglich, für einen Anoden-Kathoden-Abstand von 3 mm sinken die maximalen Driftzeiten auf 300 ns. Eine andere Alternative ist das Anlegen einer negativen Spannung an das Eintrittsfenster.
Im Rahmen dieser Arbeit wurden grundlegende Eigenschaften von GEM-Verstärkungsstrukturen untersucht. Dies waren der Einfluss des Alignmenteffektes auf die Reproduzierbarkeit von Messungen, die Elektronenextraktionseffizienz von GEMs im allgemeinen und die Auswirkungen von Druckschwankungen auf die Gasverstärkung. Weiterhin wurden verschiedene vierlagige GEM-Verstärkungssysteme mit einer MP-GEM an erster Stelle in Hinblick auf Ionenrückfluss und Energieauflösung untersucht.
Der Alignmenteffekt ist noch nicht vollkommen verstanden und verlangt weitere Untersuchungen. Was aber definitiv gesagt werden kann ist, dass das Drehen der GEMs um 90° die Reproduzierbarkeit der Messergebnisse sicherstellt.
Die unterschiedlichen Elektronenextraktionseffizienzen der verschiedenen GEM-Typen sind noch unverstanden. Auch wenn die grundsätzliche Zunahme der Extraktion mit zunehmenden Transferfeld verständlich ist, so bleibt vor allem das Verhalten einer LP-GEM in diesem Kontext bis jetzt unerklärlich.
Die Versuche mit einer MP-GEM an erster Stelle einer vierlagigen Verstärkungsstruktur haben sich als keine Verbesserung im Vergleich zu den S-Konfigurationen herausgestellt. Auch wenn manche gefundenen Einstellungen die Kriterien von einem IBF von weniger als 1 % und einem σ(55Fe) von weniger als 12 % gleichzeitig erfüllen, liegen diese Messpunkte so knapp an den definierten Grenzen, dass sie nicht für den Betrieb in der Spurendriftkammer von ALICE geeignet sind. Eine Erkenntnis, die trotzdem gewonnen werden konnte, ist, dass sich das Verhalten von verschiedenen Konfigurationen verstehen lässt. So ist die beste untersuchte Konfiguration die MP-LP-LP-S-Konfiguration gewesen, danach folgte die MP-S-LP-S und als schlechteste hat die MP-S-LP-SP-Konfiguration abgeschnitten. Dies ist genau die gleiche Reihenfolge, wie sie auch bei den S-Konfigurationen auftritt: S-LP-LP-S, dann S-S-LP-S und danach S-S-LP-SP. Ein wichtiger Schritt in einem guten Kompromiss zwischen Ionenrückfluss und σ(55Fe), scheinen zwei LP-GEMs an zweiter und dritter Stelle zu sein und weniger der Lochabstand der letzten GEM.
Die Druckabhängigkeit der Gasverstärkung hat einen großen Einfluss auf die Verstärkung und damit auf die Reproduzierbarkeit von Messungen. Bei einem Höhenunterschied von ca. 400 m ergibt sich eine Änderung der Verstärkung von ca. 35 %. Zusätzlich wird dieser Effekt von lokalen Wetterbedingungen überlagert. Der Einfluss des Luftdruckes kann jedoch mit dem Fit in Abbildung 43 berücksichtigt und damit herausgerechnet werden
Zur Erforschung des Strahlstransports durch zwei Toroidsegmente wurden im Rahmen dieser Arbeit theoretische Betrachtungen, Simulationen und experimentelle Untersuchungen durchgeführt. Dazu wurde ein toroidaler Teststand, bestehend aus zwei 30 Grad Toroidsegmenten mit einer magnetischen Feldstärke von 0,6 T und einer Driftsektion zwischen diesen beiden Magneten von 400 mm Länge, verwendet. Von einer Volumenionenquelle wurde ein Wasserstoffionenstrahl erzeugt und dieser mittels eines Solenoids angepasst und in das erste Toroidsegment eingeschossen. Mit Hilfe eines beweglichen Detektors konnte der Ionenstrahl an jeder Position im Rezipienten beim Transport durch den toroidalen Aufbau experimentell untersucht und vermessen werden.
Bei den Experimenten mit dem vorhandenen Detektor konnten auf den Aufnahmen der Leuchtdichteverteilung starke Sekundärelektroneneffekte beobachtet werden, welche die Untersuchung des Ionenstrahls mit dem Detektor erschwerten oder teilweise ganz unmöglich machten. Aus diesem Grund wurde zur Unterdrückung dieser Elektronen eine Wasserstoffatmosphäre im Rezipienten aufgebaut, welche die Elektronen stärker absorbiert als die Ionen und damit die Beobachtung des Ionenstrahls ermöglichen sollte. Auf diesem Wege lässt sich das transversale Verhalten des Strahls beim Strahltransport durch die toroidalen Magnetfelder mit dem vorhandenen Detektor untersuchen. Die Auswirkungen des Wasserstoffgases auf die geladenen Teilchen wurden dabei theoretisch und experimentell untersucht und analysiert. Die Auswirkung von Helium-, Stickstoff- und Argongas auf den Ionenstrahl und die Elektronen wurde in diesem Zusammenhang experimentell betrachtet.
Des Weiteren wurde mit Hilfe des Computerprogramms TBT der Strahltransport durch die zwei toroidalen Magnetfeldsegmente unter Verwendung von Referenzeinstellungen simuliert und die Ergebnisse mit den theoretischen und experimentellen Daten des Strahltransports verglichen. Bei diesen Simulationen konnten die Gyrationsbewegungen sowie die Transmission des Ionenstrahls durch die Driftsektion genauer untersucht werden.
Da die Magnetfelder der Toroidsegmente auch in der Driftsektion als Führungsfelder dienen sollen, sind die im experimentellen Aufbau verwendeten Toroidsegmente nicht magnetisch geschirmt. Dies hat zur Folge, dass das von den Magneten erzeugte Feld Auswirkungen auf andere Komponenten des toroidalen Teststandes besitzt. Aus diesem Grund wurden die Auswirkungen dieser Magnetfelder auf die Ionenquelle sowie auf das Druckmesssystem des Teststands genauer betrachtet.
Diese Arbeit beschäftigt sich mit der Wasserkühlung einer normalleitenden CH-Kavität. Insbesondere stellt sich die Frage, ob die im CST Thermal Steady State Solver simulierten Temperaturen mit Messungen während High Power Tests übereinstimmen. Zusätzlich interessiert, inwiefern die Temperatur über die dissipierte Leistung aus dem CST Eigenmode Solver und dem gemessenen Volumenstrom im Kanal abgeschätzt werden kann. In dem Kontext wird auch geklärt, ob die Reihenschaltung der Mantelkanäle den Kühlanforderungen genügt.
Neben Volumenstrom- und Druckmessungen an den in Reihe und parallelgeschalteten Kanälen werden die Leistungs- und Temperaturwerte der Konditionierung in sämtlichen Simulationen aufgegriffen. Indem die Kavität in einzelne Sektionen unterteilt wird und in diesen die dissipierte Leistung mit dem Eigenmode Solver simuliert wird, die ein Kühlkanal abführt, werden die Temperaturerhöhungen direkt berechnet und verglichen.
Zusammengefasst hat sich der Durchfluss in kritischen Bauteilen wie den Stützen durch die Reihenschaltung der Mantelkanäle erhöht und wird damit empfohlen. Es werden die simulierten Temperaturverteilungen gezeigt. Die Näherung über den Eigenmode Solver liefert erneut für die thermisch belasteten Bauteile wie die Stützen präzise Vorhersagen.
Abschließend werden Erfahrungen aus dem Institut in dieser Arbeit zusammengetragen und die Verwendung des Steady State Solver freigegeben.
This work derives the value of the neutron capture cross section of 60Fe at the energy of kT = 25 meV. Iron plays an important role in stellar nucleosynthesis, because it is a seed material for the s-process, a neutron capture process in which the elements between iron and bismuth are synthesized.
To determine the thermal neutron cross section of 60Fe, an iron sample produced in the framework of the ERAWAST1 program at the Paul Scherrer Institute in Switzerland was irradiated at the research reactor TRIGA2 at Johannes Gutenberg University in Mainz, Germany. Before the irradiation, the number of 60Fe particles in the sample was calculated using the decay scheme of 60Fe. There were (8.207 ± 0:066 stat 0:298 syst) * 10 14 60Fe particles in the sample.
The irradiation of the sample took place in May 2012. The counting of the reaction product, 61Fe, was undertaken using a HPGe detector located in a laboratory at Johannes Gutenberg University in Mainz. Knowing the number of 60Fe particles in the sample, the number of produced 61Fe particles and the neutron flux from the reactor, the thermal neutron capture cross section of ρth60Fe = (0.203 ± 0:021 stat 0:024 syst) b could be determined.
The determination of the thermal neutron capture cross section at the energy of kT = 25 meV constitutes to the first at this energy. There was already a measurement of the neutron capture cross section of 60Fe at the energy of kT = 25 keV in Karlsruhe in Germany. The result of the measurement was 25 keV = (9.9 ± 2:8 syst 1:4 stat) mb and was published in the year 2009 [14].
Adding datapoints for the cross section at different energies improves extarpolation and helps verification of theoretical models for elemental synthesis. For this reason, a measurement of the 60Fe neutron capture cross section at the energy of kT = 90 keV is planned at Goethe University Frankfurt, Germany.
Having the neutron capture cross section of 60Fe at the energy of kT = 25 keV measured in the year 2009 in Karlsruhe [14], at the energy of kT = 25 meV measured in May 2012 at Johannes Gutenberg University in Mainz and at the planned energy of kT = 90 keV at Goethe University Frankfurt, there will be three points for the extrapolation of the values for the neutron capture cross section of 60Fe. This will lead to a significant reduction in uncertainty with respect to existing theoretical discrepancies.
The following thesis is the description and the analysis of time resolution measurements of the plastic scintillator protorypes bar with PMT (photomultiplier tube) readout, performed with a 31 MeV electron beam at the HZDR (Helmholtz-Zentrum Dresden-Rossendorf) [1]. Similar bars will be used as building blocks for the NeuLAND detector (new large area neutron detector) - a ToF (time of flight) wall within the R3B setup (Reactions with Relativistic Radioactive Beams [2]) at the future FAIR facility (GSI Darmstadt [3]). The superconducting ELBE (electron linear-accellerator for beams of high brilliance and low emittance) was used as an electron source. The scintillation material used was RP408.
Two series of measurements were made within three months. In the first series, three bars of different sizes (200 x 5 x 5 cm3; 200 x 3 x 3 cm3; 300 x 5 x 5 cm3, the latter was made by coupling one 100 cm bar with a 200 cm bar using silicon grease) were used in the experiment consecutively. They had one Hamamatsu R8619 photomultiplier tube with an active diameter of 22 mm attached to each side with silicon grease. A measurement with the 200 x 5 x 5 cm3 bar without silicon grease was also performed.
In the second series, two equal scintillator bars (270 x 5 x 5 cm3 with a 10 cm light guide) on each side were used. Measurements with and without silicon coupling as well as with two different types of PMTs (R8619 and R2059) were executed.
Time and charge signals were processed with the TACQUILA electronic board. The time resolution was measured with the very precise pulsed electron signal of the accelerator. The time resolution measurements resulted in ρ200x5x5 ~ 159 ps; ρ200x5x5,no silicon ~ 162 ps; ρ200x3x3 ~ 153 ps; ρ300x5x5 ~ 204 ps.
For the second date they resulted in ρR8619 ~ 149 ps; ρR8619, no silicon ~ 175 ps; ρR2059 ~ 141 ps.
More tests and analysis is required until the results are definite.
Erwärmt man Eis, so brechen die Molekülbindungen auf und bei einer kritischen Temperatur von 0°C entsteht durch einen Phasenübergang flüssiges Wasser. Dies ist wohl bekannt und das Phasendiagramm, sowie die Anomalie von Wasser ein bekanntes Hilfsmittel in Physik und Chemie. Doch was passiert, wenn man Kernmaterie erhitzt? Kann diese auch verschiedene Aggregatzustände annehmen? Physiker erwarten, dass ab einer definierten kritischen Temperatur auch die Bindungen zwischen den kleinsten Teilchen unserer Materie, den Quarks, aufbrechen und das bis dahin bestehende Hadronengas in ein Quark-Gluon-Plasma übergeht. In Experimenten auf der ganzen Welt sollen die Eigenschaften des Quark-Gluon- Plasmas und der Phasenübergang der Materie untersucht werden. Daraus möchte man ein Phasendiagramm für die hadronische Materie entwickeln (Abb. 1). In verschiedenen Experimenten werden die unterschiedlichen Stationen des Phasendiagramms abgelaufen. Die laufenden Projekte an den großen Teilchenbeschleuniger Anlagen am LHC (Large Hadron Collider) am CERN (Conseil Européen pour la Abbildung 1: Das Phasendiagramm stark wechselwirkender Materie. Aufgetragen ist die Temperatur gegen die Baryonendichte. Der braune Bereich stellt den Übergangsbereich zwischen Hadronengas und Quark-Gluon-Plasma dar [ZAM]. Recherche Nucléaire) und am RHIC (Relativistic Heavy Ion Collider) in Brookhaven untersuchen das Phasendiagramm bei hohen Temperaturen und geringen Dichten. An der neuen, noch im Aufbau befindlichen Beschleunigeranlage FAIR (Facility for Antiproton and Ion Research) soll nun, im Rahmen des CBM-Experiment (Compressed Baryonic Matter), das Phasendiagramm bei hohen baryonischen Dichten und geringeren Temperaturen untersucht werden. Dafür werden spezielle Detektorkomplexe entwickelt. Diese werden benötigt, um herauszufinden, wann ein Quark-Gluon-Plasma vorliegt. Hierbei ist die Identifizierung von Elektronen von großer Bedeutung. Beim CBM-Experiment wird zur Unterscheidung zwischen Pionen und Elektronen unter anderem ein Transition Radiation Detektor (TRD) verwendet. (Kapitel 4) Dessen Eingangsfenster besteht aus einer dünnen Mylar®-Folie, welche empfindlich auf Druckschwankungen reagiert. Dies führt zu einer Veränderung des Kammervolumens, was zu einer Variation der Gasverstärkung und des daraus gewonnenen Signals führt. Die Auswirkungen von Druckschwankungen auf das Eingangsfenster des CBM-TRDs sollen in der folgenden Arbeit anhand von Simulationen (Kapitel 5) sowie anhand von Messungen (Kapitel 6) untersucht und verglichen werden. Zunächst wird jedoch ein Überblick der Grundlagen gegeben.
In der vorliegenden Arbeit werden Stabilitätstests an einer Vieldrahtproportionalkammer nach ALICE-Geometrie vorgestellt. Wegen elektrischer Instabilitäten, das heißt dem Abschalten der Hochspannungsversorgung einzelner Kammern aufgrund von Entladungen an der Ausleseebene, wurde die ALICE-TPC bisher mit zwei unterschiedlichen Gasmischungen betrieben. Es wurden die Gasmischungen Ne-CO2 (90-10) und Ne-CO2-N2 (90-10-5) verwendet.
In dieser Arbeit soll nun mit systematischen Stabilitätstests mit einer α- und einer γ-Quelle am Testaufbau am IKF untersucht werden, ob eine Beimischung von Stickstoff zur Gasmischung Ne-CO2 wirklich positive Auswirkungen auf die elektrische Stabilität der Vieldrahtproportionalkammern der ALICE-TPC hat. Messungen mit der Gasmischung Ar-CO2 (90-10) dienen dabei als Referenzmessungen.
Zunächst wurden vorbereitende Messungen zum bessseren Verständnis des Einflusses der Ausleseelektronik auf die Padsignale am Testaufbau durchgeführt. Die Untersuchung der von einem Pulser induzierten Signale zeigt, dass keine Korrektur der Nullverschiebung nötig ist. Auÿerdem konnten durch diese Messung die Verstärkungsfaktoren des verwendeten Hauptverstärkers ermittelt werden. Ein weiterer wichtiger Faktor für Stabilitätstests ist die Genauigkeit des Mischungsverhältnisses des Gases. Um eine hohe Genauigkeit zu gewährleisten, wurde der Gasfliss der verschiedenen Kanäle des zur Herstellung der Gasmischung genutzten Gasmischers überprüft und so die Bereiche für den Gasfluss gefunden, in denen sich das Mischungsverhältnis nicht ändert.
Eine gute Auflösung kann mit Vieldrahtproportionalkammern erreicht werden, wenn die Kammern auch bei einem möglichst groÿen Gain noch stabil betrieben werden können. Um den Gain aus Anodestrommessungen bestimmen zu können, wurden die Primärströme für die α- und die γ-Quelle ermittelt.
Frühere Messungen mit einer γ-Quelle, aufgrund derer Stickstoff als Beimischung in den Fokus rückte, ließen vermuten, dass sich durch die Beimischung von Stickstoff die Stabilität der Auslesekammern verbessern lassen würde. Die durchgeführten Messungen mit der γ-Quellen sollten diese Aussage nun überprüfen. Sie können die früheren Ergebnisse jedoch nicht bestätigen, sondern zeigen, dass die Gasmischung Ne-CO2-N2 (90-10-5) im Gegensatz zur Gasmischung Ne-CO2 (90-10) bei Bestrahlung mit der γ-Quelle zu instabileren Bedingungen für die Auslesekammer führt.
Zum Erzeugen der Anodensignale bei Stabilitätstests wurden erstmals geladene Teilchen aus einer α-Quelle verwendet. Im Gegensatz zur Messung mit der γ-Quelle kann die Auslesekammer bei der Beimischung von Stickstoff zu Ne-CO2 bis zu einem um 25% höheren Gain stabil betrieben werden als bei der Gasmischung Ne-CO2.
Aufgrund des je nach verwendeter Quelle unterschiedlichen Effekts auf die Stabilität der Auslesekammer lässt sich nicht mit absoluter Sicherheit sagen, ob eine Beimischung von Stickstoff die gewünschten Auswirkungen hat. Allerdings werden die Spuren in der ALICE-TPC durch geladene Teilchen hervorgerufen, sodass die Messungen mit der α-Quelle den experimentellen Bedingungen bei ALICE näher kommen als die Messungen mit der γ-Quelle und deshalb die Gasmischung Ne-CO2-N2 (90-10-5) zu bevorzugen ist.
In dieser Arbeit wurden Simulationen des γ-Prozesses zu den vier p-Kernen 92;94Mo und 96;98Ru durchgeführt. Die Simulationen wurden mit den Simulationen aus [Rapp et al., 2006] verglichen, und die Ergebnisse waren bis auf wenige Ausnahmen die gleichen.
Die Untersuchung der Sensitivitäten auf insgesamt 38 geänderte Raten hat einige besonders wichtige Raten für jedes der Isotope identifiziert. Es stellte sich heraus, dass die Isotope jeweils auf eine destruktive Rate besonders sensitiv sind. Bei 92Mo war dies die 92Mo(γ,p) Rate, bei 94 die 94Mo(γ,n) Rate, bei 96Ru die 96Ru(γ,α) Rate und bei 98Ru die Destruktion über 98Ru(γ,n).
Diese Raten sind nur theoretisch bestimmt, haben aber großen Einfluss auf die Häufigkeiten der untersuchten Isotope. Experimentelle Untersuchungen dieser Raten sind nötig, um ein besseres Verständnis des γ-Prozesses in dieser Massenregion zu erlangen.
Leider konnten schon exisitierende neuere Untersuchungen im Rahmen dieser Arbeit nicht berücksichtigt werden, beispielsweise [Utsunomiya et al., 2013]. In zukünftigen Simulationen sollten diese Untersuchungen berücksichtigt werden. Außerdem sollten die Simulationen Neutroneneinfänge untersuchen, da diese vermutlich auch zur Produktion von 94Mo und 98Ru beitragen.
Ein Problem in dieser Arbeit war die Rekonstruktion der Reaktionsflüsse aus Raten und Häufigkeiten, in Zukunft sollten die Reaktionsflüsse direkt mitgeschrieben werden.
Die Unsicherheiten der Raten reichen nicht aus, um die Unterproduktion von 92;94Mo und 96;98Ru erklären. Zur Verdeutlichung dieser Tatsache befinden sich im Anhang A.15 Abbildungen der Überproduktionsfaktoren mit den geänderten Raten 92Mo(γ,p)x0.5 und 98Ru(γ,n)x0.5, also den beiden Raten, die eine Sensitivität größer eins aufweisen. Trotz der geänderten Raten werden 92Mo und 98Ru um mehr als einen Faktor 10 unterproduziert. Wenn man annehmen würde, dass die Sensitivität linear verläuft und eins beträgt, würde selbst die Reduktion der Raten auf Null nur eine Verdopplung der Häufigkeit bewirken. In der Realität wird sich die Sensitivität noch verringern, wenn andere Desintegrationsprozesse dominant werden. Es ist also nicht anzunehmen, dass die Unsicherheiten in diesen Raten die Unterproduktion erklären können. Dies war auch nicht erwartet worden[Rapp et al., 2006].
Einen größeren Einfluss auf die Endhäufigkeiten hat die Saatverteilung vor der Supernova Phase des Sterns. Diese wird durch einige entscheidende Reaktionen während der Sternentwicklung stark beeinflusst (Kapitel 1). Teilweise sind die Raten dieser Reaktionen mit großen Unsicherheiten behaftet, und eine Änderung führt zu sehr unterschiedlichen Häufigkeiten der p-Kerne [Pignatari et al., 2013]. Der Ort des p-Prozesses spielt ebenfalls eine entscheidende Rolle. Supernova Ia oder Neutronensterne könnten entscheidend zur Produktion der p-Kerne beitragen, speziell bei den leichteren Kernen mit A < 110. Diese Szenarien sind aber schwerer zu modellieren und wenig untersucht [Rauscher, 2010]. In zukünftigen Arbeiten sollten diese Szenarien genauer untersucht werden. Die Unterschiede in Saatverteilung und Temperaturverlauf sowie die neutronenreiche Umgebung einer Supernova Ia lassen veränderte Sensitivitäten erwarten.
Zum besseren Verständnis des p-Prozess sind also sowohl weitere experimentelle Daten als auch weitere Untersuchungen der Rahmenbedingungen nötig.
Ziel dieser Arbeit war, mittels einer (n,γ)-Aktivierung, 129Te zu erzeugen und eine Teilchenzahlbestimmung durchzuführen. Aktivierung der Probe am Forschungsreaktor TRIGA und Spektrenaufnahme mittels eines HPGe-Detektors erfolgten im Mai 2014 am Institut für Kernchemie der Johannes Gutenberg Universität in Mainz.
Die Teilchenzahl des Tochternuklids 129I kann anhand der Teilchenzahlen des Isomers und des Grundzustandes von 129Te berechnet werden. In den Aktivierungen #2 bis #6 wurden (14.27 ± 0.53)x10exp12 Iodnuklide erzeugt. Angegeben ist die maximal mögliche Anzahl von Iodteilchen bei unendlich langer Wartezeit und vollständigem Zerfall aller Tellurnuklide.
Beobachtet werden konnte die Abnahme der Grundzustandsaktivität bis zum Erreichen des Gleichgewichts aus Nachbevölkerung durch das Isomer und Zerfall. Die Grundzustandslinien der Energien von 459.60 keV, 487 keV, 1083 KeV und 1111 keV konnten zu dieser Untersuchung herangezogen werden. Diese 4 Linien erfüllen die erforderten Konsistenzkriterien bezüglich der Systematik und können daher zur Teilchenzahlbestimmung des Grundzustandes verwendet werden (Seite 31).
Der Einfluss der Eigenabsorption ist noch zu untersuchen, da die genaue Position der Probe im Polyethylenbehältnis nicht bestimmt werden konnte. Weiterhin ist die Datenanalyse der ersten Aktivierung aufgrund des Detektorwechsels noch nicht erfolgt. Der Austausch war wegen technischer Probleme notwendig. Ziel weiterführender Untersuchungen ist, eine erneute Halbwertszeitbestimmung des radioaktiven 129I vorzunehmen. Sie ist von Interesse, angesichts des Widerspruchs zweier Veröffentlichungen. Die Halbwertszeit des 129I kann Aufschluss über stellare Bedingungen des s-Prozesses geben.
Ziel dieser Bachelorarbeit war die Vorstellung und die Untersuchung eines effektiven, mesonischen Drei-Flavor-Modells der Quantenchromodynamik und dessen Phänomenologie. Dazu wurden zunächst die Kopplungskonstanten a und b des Modells durch die Berechnung dominanter Zerfallsbreiten der im Modell enthaltenen Axialvektor- und Pseudovektor-Mesonen festgelegt. Dabei wurde für die Festlegung der Kopplungskonstanten a der Zerfall von f1 (1420) in KK*(892) verwendet. Die so berechnete Kopplungskonstante wurde anschließend unter Verwendung des ρπ-Zerfalls von a1 (1260) auf Konsistenz geprüft. Das dadurch erhaltene Resultat von Γa1--> ρπ= (443:962 ± 13:456) MeV liegt sehr gut in dem von der particle data group angegebenen Wertebereich der Gesamtbreite von a1 (1260). Die Festlegung und Berechnung der Kopplungskonstante b des Pseudovektor-Sektors war Gegenstand der Bachelorarbeit von Lisa Olbrich, so dass in dieser Arbeit nur die Resultate dieser Rechnung präsentiert wurden. Jedoch passen die dort erzielten Resultate auch mit guter Genauigkeit zu den experimentell bestimmten Werten der particle data group.
Das zweite Ziel dieser Bachelorarbeit war die Untersuchung der im Modell enthaltenen Mischungseffekte der Kaonen-Felder von K1 (1270) und K1 (1400). Zunächst waren im Axialvektor- und Pseudovektor-Nonet dieses Modells nur unphysikalische Kaonen-Felder K1;A und K1;B enthalten. Durch den Mischungsterm Lmix der Lagrange-Dichte des Modells existieren allerdings Mischterme beider Felder. Diese Mischterme wurden durch die Einführung der physikalischen Felder K1 (1270) und K1 (1400), welche durch eine SU(2)-Drehung aus den unphysikalischen Feldern hervorgehen, zum Verschwinden gebracht. Dies hat allerdings zur Folge, dass die Wechselwirkungsterme der physikalischen Felder K1 (1270) und K1 (1400) nun über eine gedrehte Kopplungskonstante koppeln. Diese gedrehte Kopplungskonstante ist eine Funktion der ursprünglich bestimmten Kopplungskonstanten a; b und eines Mischwinkels Φ. Dieser Mischungswinkel wurde von uns über den K? (892) π-Zerfall von K1 (1270) festgelegt. Anschließend konnten wir unter Verwendung des so berechneten Mischungswinkels Φ die Zerfallsbreite von K1 (1400) berechnen und mit den experimentell festgelegten Daten der particle data group vergleichen. Auch hier konnten wir eine gute Übereinstimmung unserer durch das Modell vorhergesagten Daten mit den experimentell bestimmten Werten erzielen.