Background: Despite known clinical benefits, guideline-recommended heart rate (HR) control is not achieved for a significant proportion of patients with HF with reduced ejection fraction. The wearable cardioverter-defibrillator (WCD) provides continuous HR monitoring and alerts that could aid medication titration.
Objective: This study sought to evaluate sex differences in achieving guideline-recommended HR control during a period of WCD use.
Methods: Data from patients fitted with a WCD from 2015 to 2018 were obtained from the manufacturer’s database (ZOLL). The proportion of patients with adequate nighttime resting HR control at the beginning of use (BOU) and at the end of use (EOU) were compared by sex. Adequate HR control was defined as having a nighttime median HR <70 beats/min.
Results: A total of 21,440 women and a comparative sample of 17,328 men (median 90 [IQR 59–116] days of WCD wear) were included in the final dataset. Among patients who did not receive a shock, over half had insufficient HR control at BOU (59% of women, 53% of men). Although the proportion of patients with resting HR ≥70 beats/min improved by EOU, 43% of women and 36% of men did not achieve guideline-recommended HR control.
Conclusion: A significant proportion of women and men did not achieve adequate HR control during a period of medical therapy optimization. Compared with men, a greater proportion of women receiving WCD shocks had insufficiently controlled HR in the week preceding ventricular tachyarrhythmia/ventricular fibrillation and 43% of nonshocked women, compared with 36% of men, did not reach adequate HR control during the study period. The WCD can be utilized as a remote monitoring tool to record HR and inform adequate uptitration of beta-blockers, with particular focus on reducing the treatment gap in women.
Background: Data on the arrhythmic burden of women at risk for sudden cardiac death are limited, especially in patients using the wearable cardioverter-defibrillator (WCD).
Objective: We aimed to characterize WCD compliance, atrial and ventricular arrhythmic burden, and WCD outcomes by sex in patients enrolled in the Prospective Registry of Patients Using the Wearable Cardioverter Defibrillator (WEARIT-II U.S. Registry).
Methods: In the WEARIT-II Registry, we stratified 2000 patients by sex into women (n = 598) and men (n = 1402). WCD wear time, ventricular and atrial arrhythmic events during WCD use, and implantable cardioverter-defibrillator (ICD) implantation rates at the end of WCD use were evaluated.
Results: The mean WCD wear time was similar in women and men (94 days vs 90 days; P = .145), with longer daily use in women (21.4 h/d vs 20.7 h/d; P = .001). Burden of ventricular tachycardia or ventricular fibrillation was higher in women, with 30 events per 100 patient-years compared with 18 events per 100 patient-years in men (P = .017), with similar findings for treated and non-treated ventricular tachycardia/ventricular fibrillation. Recurrent atrial arrhythmias/sustained ventricular tachycardia was also more frequent in women than in men (167 events per 100 patient-years vs 73 events per 100 patient-years; P = .042). However, ICD implantation rate at the end of WCD use was similar in both women and men (41% vs 39%; P = .448).
Conclusion: In the WEARIT-II Registry, we have shown a higher burden of ventricular and atrial arrhythmic events in women than in men. ICD implantation rates at the end of WCD use were similar. Our findings warrant monitoring women at risk for sudden cardiac death who have a high burden of atrial and ventricular arrhythmias while using the WCD.
Decline in physical activity in the weeks preceding sustained ventricular arrhythmia in women
(2020)
Background: Heightened risk of cardiac arrest following physical exertion has been reported. Among patients with an implantable defibrillator, an appropriate shock for sustained ventricular arrhythmia was preceded by a retrospective self-report of engaging in mild-to-moderate physical activity. Previous studies evaluating the relationship between activity and sudden cardiac arrest lacked an objective measure of physical activity and women were often underrepresented.
Objective: To determine the relationship between physical activity, recorded by accelerometer in a wearable cardioverter-defibrillator (WCD), and sustained ventricular arrhythmia among female patients.
Methods: A dataset of female adult patients prescribed a WCD for a diagnosis of myocardial infarction or dilated cardiomyopathy was compiled from a commercial database. Curve estimation, to include linear and nonlinear interpolation, was applied to physical activity as a function of time (days before arrhythmia).
Results: Among women who received an appropriate WCD shock for sustained ventricular arrhythmia (N = 120), a quadratic relationship between time and activity was present prior to shock. Physical activity increased starting at the beginning of the 30-day period up until day -16 (16 days before the ventricular arrhythmia) when activity begins to decline.
Conclusion: For patients who received treatment for sustained ventricular arrhythmia, a decline in physical activity was found during the 2 weeks preceding the arrhythmic event. Device monitoring for a sustained decline in physical activity may be useful to identify patients at near-term risk of a cardiac arrest.