Refine
Year of publication
- 2008 (2) (remove)
Document Type
- Doctoral Thesis (2) (remove)
Language
- English (2)
Has Fulltext
- yes (2)
Is part of the Bibliography
- no (2)
Keywords
- CERN (2) (remove)
Institute
- Physik (2)
In this work data of the NA49 experiment at CERN SPS on the energy dependence of multiplicity fluctuations in central Pb+Pb collisions at 20A, 30A, 40A, 80A and 158A GeV, as well as the system size dependence at 158A GeV, is analysed for positively, negatively and all charged hadrons. Furthermore the rapidity and transverse momentum dependence of multiplicity fluctuations are studied. The experimental results are compared to predictions of statistical hadron-gas and string-hadronic models. It is expected that multiplicity fluctuations are sensitive to the phase transition to quark-gluon-plasma (QGP) and to the critical point of strongly interacting matter. It is predicted that both the onset of deconfinement, the lowest energy where QGP is created, and the critical point are located in the SPS energy range. Furthermore, the predictions for the multiplicity fluctuations of statistical and string-hadronic models are different, the experimental data might allow to distinguish between them. The used measure of multiplicity fluctuations is the scaled variance omega, defined as the ratio of the variance and the mean of the multiplicity distribution. In the NA49 experiment the tracks of charged particles are detected in four large volume time projection chambers (TPCs). In order to remove possible detector effects a detailed study of event and track selection criteria is performed. Naively one would expect Poisson fluctuations in central heavy ion collisions. A suppression of fluctuations compared to a Poisson distribution is observed for positively and negatively charged hadrons at forward rapidity in Pb+Pb collisions. At midrapidity and for all charged hadrons the fluctuations are larger than the Poisson ones. The fluctuations seem to increase with decreasing system size. It is suggested that this is due to increased relative fluctuations in the number of participants. Furthermore, it was discovered that omega increases for decreasing rapidity and transverse momentum. A hadron-gas model predicts different values of omega for different statistical ensembles. In the grand-canonical ensemble, where all conservation laws are fulfilled only on the average, not on an event-by-event basis, the predicted fluctuations are the largest ones. In the canonical ensemble the charges, namely the electrical charge, the baryon number and the strangeness, are conserved for each event. The scaled variance in this ensemble is smaller than for the grand-canonical ensemble. In the micro-canonical ensemble not only the charges, but also the energy and the momentum are conserved in each event, the predicted $omega$ is the smallest one. The grand-canonical and canonical formulations of the hadron-gas model over-predict fluctuations in the forward acceptance. In contrast to the experimental data no dependence of omega on rapidity and transverse momentum is expected. For the micro-canonical formulation, which predicts small fluctuations in the total phase space, no quantitative calculation is available yet for the limited experimental acceptance. The increase of fluctuations for low rapidities and transverse momenta can be qualitatively understood in a micro-canonical ensemble as an effect of energy and momentum conservation. The string-hadronic model UrQMD significantly over-predicts the mean multiplicities but approximately reproduces the scaled variance of the multiplicity distributions at all measured collision energies, systems and phase-space intervals. String-hadronic models predict for Pb+Pb collisions a monotonous increase of omega with collision energy, similar to the observations for p+p interactions. This is in contrast to the predictions of the hadron-gas model, where omega shows no energy dependence at higher energies. At SPS energies the predictions of the string-hadronic and hadron-gas models are in the same order of magnitude, but at RHIC and LHC energies the difference in omega in the full phase space is much larger. Experimental data should be able to distinguish between them rather easily. Narrower than Poissonian (omega < 1) multiplicity fluctuations measured in the forward kinematic region (1<y(pi)<y_{beam}) can be related to the reduced fluctuations predicted for relativistic gases with imposed conservation laws. This general feature of relativistic gases may be preserved also for some non-equilibrium systems as modeled by the string-hadronic approaches. A quantitative estimate shows that the predicted maximum in fluctuations due to a first order phase transition from hadron-gas to QGP is smaller than the experimental errors of the present experiment and can therefore neither be confirmed nor disproved. No sign of increased fluctuations as expected for a freeze-out near the critical point of strongly interacting matter is observed.
ALICE (A Large Ion Collider Experiment), is the dedicated heavy-ion experiment at the Large Hadron Collider (LHC) at CERN. It is optimised to reconstruct and identify the particles created in a lead-lead collision with a centre of mass energy of 5.5TeV. The main tracking detector is a large-volume time-projection chamber (TPC). With an active volume of about 88m^3 and a total readout area of 32.5m^2 it is the most challenging TPC ever build. A central electrode divides the 5m long detector into two drift regions. Each readout side is subdivided into 18 inner and 18 outer multi-wire proportional read-out chambers. The readout area is subdivide into 557568 pads, where each pad is read out by and electronics chanin. A complex calibration is needed in order to reach the design position-resolution of the reconstructed particle tracks of about 200um. One part of the calibration lies in understanding the electronic-response. The work at hand presents results of the pedestal and noise behaviour of the front-end electronics (FEE), measurements of the pulse-shaping properties of the FEE using results obtained with a calibration pulser and measurements performed with the laser-calibration system. The data concerned were taken during two phases of the TPC commissioning. First measurements were performed in the clean room where the TPC was built. After the TPC was moved underground and built into the experiment, a second round of commissioning took place. Noise measurements in the clean room revealed a very large fraction of pads with noise values larger than the design specifications. The unexpected high noise values could be explained by the 'ground bounce' effect. Two modifications helped to reduce this effect: A desynchronisation in the the start of the readout of groups of channels and a modification in the grounding scheme of the FEE. Further noise measurements were carried out after the TPC has been moved to the experimental area underground. Here even a larger fraction of channels showed too large noise values. This could be traced back to a common mode current injected by the electronics power supplies. To study the shaping properties of the FEE a calibration pulser was used. To generate signals in the FEE a pulse is injected to the cathode wires of the read-out chambers. Due to manufacturing tolerances slight channel-by-channel variations of the shaping properties are expected. This effects the determination of the arrival time as well as the measured integral signal of the induced charge and has to be corrected. The measured arrival time variations follow a Gaussian distribution with a width (sigma) of 6.2ns. This corresponds to an error of the cluster position of about 170um. The charge variations are on the level of 2.8%. In order to reach the intrinsic resolution on the measurement of the specific energy loss of the particles (6%) those variations have to be taken into account. The photons of the laser-calibration system are energetic enough to emit photo electrons off metallic surfaces. Most interesting for the detector calibration are photo electrons from the central electrode. The laser light is intense enough to get a signal in all readout channels of the TPC. Since the central electrode is a smooth surface, differences in the arrival time between sectors reveal mechanical displacements of the readout sectors and can be used to correct for this effect. In addition the measurements can be used to determine the electron drift velocity in the TPC gas. The drift velocity measurements have shown a vertical as well as a radial gradient. The first can be explained by the temperature gradient, which naturally builds up in the 5m high detector. The second gradient is most probably caused by a relative conical deformation of the readout plane and the central electrode.