Refine
Document Type
- Doctoral Thesis (2)
Language
- English (2) (remove)
Has Fulltext
- yes (2)
Is part of the Bibliography
- no (2)
Keywords
- Kalibrieren <Messtechnik> (2) (remove)
Institute
- Physik (2)
ALICE (A Large Ion Collider Experiment), is the dedicated heavy-ion experiment at the Large Hadron Collider (LHC) at CERN. It is optimised to reconstruct and identify the particles created in a lead-lead collision with a centre of mass energy of 5.5TeV. The main tracking detector is a large-volume time-projection chamber (TPC). With an active volume of about 88m^3 and a total readout area of 32.5m^2 it is the most challenging TPC ever build. A central electrode divides the 5m long detector into two drift regions. Each readout side is subdivided into 18 inner and 18 outer multi-wire proportional read-out chambers. The readout area is subdivide into 557568 pads, where each pad is read out by and electronics chanin. A complex calibration is needed in order to reach the design position-resolution of the reconstructed particle tracks of about 200um. One part of the calibration lies in understanding the electronic-response. The work at hand presents results of the pedestal and noise behaviour of the front-end electronics (FEE), measurements of the pulse-shaping properties of the FEE using results obtained with a calibration pulser and measurements performed with the laser-calibration system. The data concerned were taken during two phases of the TPC commissioning. First measurements were performed in the clean room where the TPC was built. After the TPC was moved underground and built into the experiment, a second round of commissioning took place. Noise measurements in the clean room revealed a very large fraction of pads with noise values larger than the design specifications. The unexpected high noise values could be explained by the 'ground bounce' effect. Two modifications helped to reduce this effect: A desynchronisation in the the start of the readout of groups of channels and a modification in the grounding scheme of the FEE. Further noise measurements were carried out after the TPC has been moved to the experimental area underground. Here even a larger fraction of channels showed too large noise values. This could be traced back to a common mode current injected by the electronics power supplies. To study the shaping properties of the FEE a calibration pulser was used. To generate signals in the FEE a pulse is injected to the cathode wires of the read-out chambers. Due to manufacturing tolerances slight channel-by-channel variations of the shaping properties are expected. This effects the determination of the arrival time as well as the measured integral signal of the induced charge and has to be corrected. The measured arrival time variations follow a Gaussian distribution with a width (sigma) of 6.2ns. This corresponds to an error of the cluster position of about 170um. The charge variations are on the level of 2.8%. In order to reach the intrinsic resolution on the measurement of the specific energy loss of the particles (6%) those variations have to be taken into account. The photons of the laser-calibration system are energetic enough to emit photo electrons off metallic surfaces. Most interesting for the detector calibration are photo electrons from the central electrode. The laser light is intense enough to get a signal in all readout channels of the TPC. Since the central electrode is a smooth surface, differences in the arrival time between sectors reveal mechanical displacements of the readout sectors and can be used to correct for this effect. In addition the measurements can be used to determine the electron drift velocity in the TPC gas. The drift velocity measurements have shown a vertical as well as a radial gradient. The first can be explained by the temperature gradient, which naturally builds up in the 5m high detector. The second gradient is most probably caused by a relative conical deformation of the readout plane and the central electrode.
Die vorliegende Arbeit beschäftigt sich mit der Charakterisierung des ALTRO Chips (ALICE TPC Readout), der ein integraler und wichtiger Bestandteil der Auslesekette des TPC (Time Projection Chamber) Detektors von ALICE (A Large Ion Collider Experiment) ist. ALICE ist ein Experiment am noch im Bau befindlichen LHC (Large Hadron Collider) am CERN mit der zentralen Ausrichtung, Schwerionenkollisionen zu untersuchen. Diese sind von besonderem Interesse, da durch sie ein experimenteller Zugriff zu dem QGP (Quark Gluon Plasma) existiert, dem einzigen vom Standardmodell vorhergesagten Phasenübergang, der unter Laborbedingungen erreichbar ist. Im Jahr 2004 wurden Messungen an einem Teststrahl am CERN PS (Proton Synchrotron) durchgeführt. Der Prototyp wurde voll mit FECs bestückt, was 5400 Kanälen entspricht und einer anderen Gasmixtur (Ne/N2/CO2 90%/5%/5%) befüllt. Für das optimale Leistungsverhalten der ALICE TPC muß der Digitalprozessor im ALTRO, bestehend aus vier Berechnungseinheiten, mit den passenden Werten konfiguriert werden. Der Datenfluss beginnt mit dem BCS1 (Baseline Correction and Subtraction 1) Modul, das systematische Störungen und die Grundlinie entfernt. Da der ALTRO kontinuierlich das anliegende Signal abtastet, entfernt es automatisch langsame Grundlinienveränderungen, die Beispielsweise durch Temperaturänderungen auftreten können. Gefolgt von dem TCF (Tail Cancellation Filter), der den Schweif des langsam fallenden, vom PASA generierten Signals entfernt. Um die nichtsystematischen Störungen der Grundlinie zu entfernen, folgt die BCS2 (Baseline Correction and Subtraction 2), die auf einer gleitenden Mittelwertsberechnung mit Ausschluß von Detektorsignalen über einen doppelten Schwellenwert basiert. Die finale Einheit für die Signalverarbeitung ist die ZSU (Zero Suppression Unit), die Meßpunkte unterhalb eines definierten Schwellwertes entfernt. Hier wird der weg beschrieben die TCF und BCS1 Parameter aus vorhandenen Detektordaten zu extrahieren. Während der Analyse der Daten von kosmischen Teilchen fiel bei Signalen mit hoher Amplitude (>700 ADC) eine zusätzliche Struktur in dem Schweif auf. Der Monitor wurde deswegen mit einem gleitenden Mittelwertfilter erweitert, worauf sich diese Struktur auch in kleineren Signalen (> 200 ADC) zeigte. Dieses Signal wird von Ionen erzeugt, die zur Kathode oder zu den Pads driften, bisher ist jedoch weder die Streuung der Elektronenlawine an der Anode, noch die Variationsbreite in den erzeugten Elektronlawinen verstanden oder gemessen worden. Eine erfolgreiche Messung, sowie Charakterisierung wird in dieser Arbeit beschrieben. Im Jahr 2005 im Sommer beginnt der Einbau der Gaskammern der TPC in ALICE, die Elektronik folgt am Ende dieses Jahres. Parallel hierzu wurde der Prototyp der TPC wieder in Betrieb genommen und im Frühling wird ein kompletter Sektor mit der Detektorelektronik ausgestattet. An diesen zwei Aufbauten wird die ALTRO Charakterisierung fortgeführt, verfeinert und komplettiert.