Refine
Year of publication
Document Type
- Article (1875)
- Preprint (1252)
- Doctoral Thesis (593)
- Conference Proceeding (248)
- diplomthesis (101)
- Bachelor Thesis (75)
- Master's Thesis (61)
- Contribution to a Periodical (46)
- Book (33)
- Diploma Thesis (33)
Keywords
- Kollisionen schwerer Ionen (47)
- heavy ion collisions (44)
- LHC (25)
- Quark-Gluon-Plasma (25)
- Heavy Ion Experiments (20)
- equation of state (19)
- quark-gluon plasma (19)
- Relativistic heavy-ion collisions (16)
- QCD (15)
- QGP (15)
Institute
- Physik (4412) (remove)
We report an amplitude analysis and branching fraction measurement of D+s→K+K−π+ decay using a data sample of 3.19 fb−1 recorded with BESIII detector at a center-of-mass energy of 4.178 GeV.
We perform a model-independent partial wave analysis in the low K+K− mass region to determine the K+K− S-wave lineshape, followed by an amplitude analysis of our very pure high-statistics sample.
The amplitude analysis provides an accurate determination of the detection efficiency allowing us to measure the branching fraction B(D+s→K+K−π+)=(5.47±0.08stat±0.13sys)%.
We report an amplitude analysis and branching fraction measurement of D+s→K+K−π+ decay using a data sample of 3.19 fb−1 recorded with BESIII detector at a center-of-mass energy of 4.178 GeV.
We perform a model-independent partial wave analysis in the low K+K− mass region to determine the K+K− S-wave lineshape, followed by an amplitude analysis of our very pure high-statistics sample.
The amplitude analysis provides an accurate determination of the detection efficiency allowing us to measure the branching fraction B(D+s→K+K−π+)=(5.47±0.08stat±0.13sys)%.
We report an amplitude analysis and branching fraction measurement of D+s→K+K−π+ decay using a data sample of 3.19 fb−1 recorded with BESIII detector at a center-of-mass energy of 4.178 GeV.
We perform a model-independent partial wave analysis in the low K+K− mass region to determine the K+K− S-wave lineshape, followed by an amplitude analysis of our very pure high-statistics sample.
The amplitude analysis provides an accurate determination of the detection efficiency allowing us to measure the branching fraction B(D+s→K+K−π+)=(5.47±0.08stat±0.13sys)%.
Using 2.93 fb−1 of 𝑒+𝑒− collision data taken at a center-of-mass energy of 3.773 GeV with the BESIII detector, we report the first measurements of the absolute branching fractions of 14 hadronic 𝐷0(+) decays to exclusive final states with an 𝜂, e.g., 𝐷0→𝐾−𝜋+𝜂, 𝐾0𝑆𝜋0𝜂, 𝐾+𝐾−𝜂, 𝐾0𝑆𝐾0𝑆𝜂, 𝐾−𝜋+𝜋0𝜂, 𝐾0𝑆𝜋+𝜋−𝜂, 𝐾0𝑆𝜋0𝜋0𝜂, and 𝜋+𝜋−𝜋0𝜂; 𝐷+→𝐾0𝑆𝜋+𝜂, 𝐾0𝑆𝐾+𝜂, 𝐾−𝜋+𝜋+𝜂, 𝐾0𝑆𝜋+𝜋0𝜂, 𝜋+𝜋+𝜋−𝜂, and 𝜋+𝜋0𝜋0𝜂. Among these decays, the 𝐷0→𝐾−𝜋+𝜂 and 𝐷+→𝐾0 𝑆𝜋+𝜂 decays have the largest branching fractions, which are ℬ(𝐷0→𝐾−𝜋+𝜂) = (1.853±0.025stat±0.031syst)% and ℬ(𝐷+→𝐾0𝑆𝜋+𝜂) = (1.309±0.037stat±0.031syst)%, respectively. The charge-parity asymmetries for the six decays with highest event yields are determined, and no statistically significant charge-parity violation is found.
Inverse modeling of circular lattices via orbit response measurements in the presence of degeneracy
(2023)
The number and location of beam position monitors (BPMs) and steerers with respect to the quadrupoles in a circular lattice can lead to degeneracy in the context of fitting linear optics and extracting lattice information from measured closed orbits. Furthermore, the measurement uncertainties due to the imperfection of BPMs and steerers can be propagated by the fitting process in ways that prohibit the successful extraction of discrepancies between lattice elements in the real machine and their description in the corresponding model. We systematically studied the influence of the placement of BPMs and steerers on the reconstruction of linear optics and corresponding lattice information. The derivative of orbit response coefficients with respect to the quadrupole strengths, the Jacobian, is derived as an analytical formula. This analytical version of the Jacobian is used to further derive the theoretical limitations of fitting linear optics from closed orbits in terms of the placement of BPMs and steerers. It is further demonstrated that when evaluating the Jacobian during the fitting procedure, the analytical version can be used in place of the conventional finite-difference computation. This allows for greatly improved efficiency when computing the Jacobian during each iteration of the fitting procedure. The approach is tested with large-scale simulations and the findings are verified by measurement data taken on SIS18 synchrotron at GSI Helmholtz Centre for Heavy Ion Research. The presented methods are of general nature and can be applied to other accelerator lattices as well. The fitting procedure by using the analytical Jacobian is tested in conjunction with various methods for mitigating quasidegeneracy and the results agree with those obtained by using the conventional Jacobian via finite-difference approximation.
We report a search for a dark photon using 14.9~fb−1 of e+e− annihilation data taken at center-of-mass energies from 4.13 to 4.60~GeV with the BESIII detector operated at the BEPCII storage ring. The dark photon is assumed to be produced in the radiative annihilation process of e+e− and to predominantly decay into light dark matter particles, which escape from the detector undetected. The mass range from 1.5 to 2.9~GeV is scanned for the dark photon candidate, and no significant signal is observed. The mass dependent upper limits at the 90% confidence level on the coupling strength parameter ϵ for a dark photon coupling with an ordinary photon vary between 1.6×10−3 and 5.7×10−3.
Using a data sample corresponding to an integrated luminosity of 11.3 fb−1 collected at center-of-mass energies from 4.23 to 4.70 GeV with the BESIII detector, we observe the process e+e− → π0π0ψ2(3823) for the first time with a statistical significance of 6.0 standard deviations. The ratio of average cross sections for e+e− → π0π0ψ2(3823) and π+π−ψ2(3823) is determined to be R = σ[e+e− → π0π0ψ2(3823)] σ[e+e−→π+π−ψ2(3823)] = 0.57 ± 0.14 ± 0.05, which is consistent with expectations from isospin symmetry. Here and below, the first uncertainties are statistical and the second are systematic. The mass of the ψ2(3823) is measured to be M[ψ2(3823)] = 3824.5±2.4±1.0 MeV/c2. Due to the limited data sample, an upper limit of 18.8 MeV at 90% confidence level is set on the intrinsic width of ψ2(3823).
Using (448.1 ± 2.9) × 106 ψ(3686) events collected with the BESIII detector at the BEPCII collider, the decay ψ(3686) → Σ⁻Σ‾⁺ is observed for the first time with a branching fraction of (2.82 ± 0.04stat. ± 0.08syst.) × 10−4, and the angular parameter αΣ− is measured to be 0.96 ± 0.09stat. ± 0.03syst..
We report the measurement of the cross sections for e+e−→hadrons at center-of-mass (c.m.) energies from 3.645 to 3.871 GeV. We observe a new resonance R(3810) in the cross sections for the first time, and observe the R(3760) resonance with high significance in the cross sections. The R(3810) has a mass of (3804.5±0.9±0.9) ~MeV/c2, a total width of (5.4±3.5±3.2)~MeV, and an electronic partial width of (19.4±7.4±12.1)~eV. Its significance is 7.7σ. The R(3810) could be interpreted as a hadro-charmonium resonance predicted by Quantum Chromodynamics (QCD). In addition, we measure the mass (3751.9±3.8±2.8) ~MeV/c2, the total width (32.8±5.8±8.7)~MeV, and the electronic partial width (184±75±86)~eV with improved precision for the R(3760). Furthermore, for the R(3780) we measure the mass (3778.7±0.5±0.3) ~MeV/c2 and total width (20.3±0.8±1.7)~MeV with improved precision, and the electronic partial width (265±69±83)~eV. The R(3780) can be interpreted as the 13D1 state of charmonium. Its mass and total width differ significantly from the corresponding fitted values given by the Particle Data Group in 2022 by 7.1 and 3.2 times the uncertainties for ψ(3770), respectively. ψ(3770) has been interpreted as the 13D1 state for 45 years.
Using a data sample corresponding to an integrated luminosity of 2.93 fb−1 collected at a center-of-mass energy √𝑠=3.773 GeV by the BESIII detector, the decay 𝐷0→𝜔𝜙 is observed for the first time. The branching fraction is measured to be (6.48±0.96±0.40)×10−4 with a significance of 6.3𝜎, where the first and second uncertainties are statistical and systematic, respectively. An angular analysis reveals that the 𝜙 and 𝜔 mesons from the 𝐷0→𝜔𝜙 decay are transversely polarized. The 95% confidence level upper limit on longitudinal polarization fraction is set to be less than 0.24, which is inconsistent with current theoretical expectations and challenges our understanding of the underlying dynamics in charm meson decays.
Using a data sample corresponding to an integrated luminosity of 2.93 fb−1 collected at a center-of-mass energy s√=3.773 GeV by the BESIII detector, the decay D0→ωϕ is observed for the first time. The branching fraction is measured to be (6.48±0.96±0.38)×10−4 with a significance of 6.3σ, where the first and second uncertainties are statistical and systematic, respectively. An angular analysis reveals that the ϕ and ω mesons from the D0→ωϕ decay are transversely polarized.
Using a data sample corresponding to an integrated luminosity of 2.93 fb−1 collected at a center-of-mass energy s√=3.773 GeV by the BESIII detector, the decay D0→ωϕ is observed for the first time. The branching fraction is measured to be (6.48±0.96±0.38)×10−4 with a significance of 6.3σ, where the first and second uncertainties are statistical and systematic, respectively. An angular analysis reveals that the ϕ and ω mesons from the D0→ωϕ decay are transversely polarized, which is inconsistent with current theoretical expectations and challenges our understanding of the underlying dynamics in charm meson decays.
Using a data sample corresponding to an integrated luminosity of 2.93 fb−1 collected at a center-of-mass energy s√=3.773 GeV by the BESIII detector, the decay D0→ωϕ is observed for the first time. The branching fraction is measured to be (6.48±0.96±0.40)×10−4 with a significance of 6.3σ, where the first and second uncertainties are statistical and systematic, respectively. An angular analysis reveals that the ϕ and ω mesons from the D0→ωϕ decay are transversely polarized. The 95% confidence level upper limit on longitudinal polarization fraction is set to be less than 0.24, which is inconsistent with current theoretical expectations and challenges our understanding of the underlying dynamics in charm meson decays.
Using data samples with a total integrated luminosity of 20.1 fb−1 collected by the BESIII detector operating at the BEPCII collider, the cross section of the process 𝑒+𝑒−→𝜋+𝜋−𝜓(3686) is measured at center-of-mass energies between 4.0076 and 4.6984 GeV. The measured cross section is consistent with previous results, and with much improved precision. A fit to the measured energy-dependent cross section, which includes three Breit-Wigner functions and a nonresonant contribution, confirms the existence of the charmonium-like states 𝑌(4220), 𝑌(4390), and 𝑌(4660). This is the first observation of the 𝑌(4660) at the BESIII experiment.
Das radioaktive Edelgas Radon und seine ebenfalls radioaktiven Zerfallsprodukte machen den größten Teil der natürlichen Strahlenbelastung in Deutschland aus. Trotz der Einstufung als krebserregend für Lungenkrebs wird es zur Therapie entzündlicher Krankheiten eingesetzt. Der hauptsächliche Aufnahmemechanismus ist dabei die Inkorporation über die Atmung, wobei Radon auch über die Haut aufgenommen werden kann. Radon wird dabei über das Blut im gesamten Körper verteilt und kann in Gewebe mit hoher Radonlöslichkeit akkumulieren. Die Zerfallsprodukte verbleiben jedoch in der Lunge, zerfallen dort, bevor sie abtransportiert werden können und schädigen das dortige Gewebe.
Die Lungendosis wird laut Simulationen zum größten Teil durch die kleinsten Radon-Zerfallsprodukte (< 10 nm) bestimmt, die besonders effektiv im Respirationstrakt anheften. Die erzeugte Dosis ist dabei aufgrund der inhomogenen Anlagerung der Zerfallsprodukte lokal stark variabel. In Simulationen wurden Bifurkationen als Ort besonders hoher Deposition identifiziert, wobei die experimentelle Datenlage zur Deposition kleinster Radon-Zerfallsprodukte eingeschränkt ist. Aufgrund des Anstiegs der Komplexität von Simulationen oder Experimenten wird in den meisten Betrachtungen nicht der oszillatorische Atemzyklus berücksichtigt, sondern lediglich ein einseitig gerichteter Luftstrom betrachtet. Im Rahmen dieser Arbeit wurde ein experimentelles Modell entwickelt und etabliert, das die Messung der Deposition von Radon-Zerfallsprodukten ermöglicht und zwischen drei Größenfraktionen (Freie Zerfallsprodukte: < 10 nm, Cluster: 20-100 nm, Angelagerte Zerfallsprodukte: > 100 nm) unterscheiden kann. Der Luftfluss durch das Modell bildet sowohl die Inhalation als auch die Exhalation ab. Erste Experimente mit dem neu entwickelten Messaufbau konnten die aus Simulationen bekannte erhöhte Deposition der freien Zerfallsprodukte in einer Bifurkation abbilden. Die Vergrößerung des Bifurkationswinkels von 70° auf 180° zeigte lediglich einen minimalen Anstieg in der Größenordnung des Messfehlers. Der dominierende Prozess der Anlagerung der freien Zerfallsprodukte ist die Brown'sche Molekularbewegung, die unabhängig vom Bifurkationswinkel ist. Dennoch kann ein veränderter Winkel die Luftströmung und entstehende Turbulenzen verändern, wodurch die Deposition beeinflusst werden kann. Dies lässt sich jedoch mit dem hier benutzten Messaufbau nicht auflösen. Entgegen der Beobachtungen in der Literatur führte die Erhöhung der Atemfrequenz von 12 auf 30 Atemzüge pro Minute, in den im Rahmen dieser Arbeit durchgeführten Experimenten, zu keiner messbaren Veränderung der Deposition. Diese Beobachtung ist auf die Entstehung gegensätzlicher Effekte zurückzuführen. Einerseits führt eine schnellere Luftströmung zu kürzeren Aufenthaltszeiten der freien Zerfallsprodukte im Modell, wodurch die Deposition unwahrscheinlicher wird. Andererseits entstehen vermehrt sekundäre Strömungen und absolut betrachtet werden mehr Partikel durch das Modell gepumpt. Es ist davon auszugehen, dass sich diese Effekte im hier getesteten Bereich aufheben.
Als potentielle Schutzmaßnahme zur Reduktion der Lungendosis konnte im Rahmen dieser Arbeit die Filtereffzienz von Gesichtsmasken (OP-Masken, FFP2 Masken) gegenüber Radon und seinen Zerfallsprodukten bestimmt werden. Während Radon nicht gefiltert wird, wurden die freien Zerfallsprodukte fast vollständig (> 98%) und die Cluster zum größten Teil (≈ 80 %) zurückgehalten.
Radon selbst kann im gesamten Organismus verteilt werden und dort in Gewebe akkumulieren. Zur Bestimmung der Dosis wird dabei auf biokinetische Modelle zurückgegriffen. Diese sind von der Qualität ihrer Eingabeparameter abhängig, wobei beispielsweise die Werte zur Verteilung von Radon zwischen Blut und Gewebe auf experimentell gewonnenen Löslichkeitswerten aus Mäusen und Ratten beruhen. Unbekannte Werte werden von der Internationalen Strahlenschutzkommission basierend auf der Gewebezusammensetzung als gewichteter Mittelwert berechnet. In dieser Arbeit wurde die Löslichkeit in humanen Blutproben und wässrigen Lösungen verschiedener Konzentrationen der Blutproteine Hämoglobin und Albumin bestimmt. Es löste sich mehr Radon in Plasma als in Erythrozytenkonzentrat und Vollblut. Die Protein-Lösungen zeigten keine Konzentrationsabhängigkeit der Löslichkeit, sondern lediglich in hitzedenaturiertem Hämoglobin wurde eine niedrigere Löslichkeit gemessen. Basierend auf diesen Beobachtungen, sollte die These überprüft werden, ob sich die Löslichkeit einer Mischung als gewichteter Mittelwert der einzelnen Löslichkeiten berechnen lässt. Daher wurden diese in einer Mischung aus zwei Flüssigkeiten (1-Pentanol, Ölsäure) bestimmt. Die experimentell bestimmte Löslichkeit war dabei fast doppelt so groß wie der berechnete Wert. Dieser Unterschied kann dadurch zustande kommen, dass bei einer Berechnung basierend auf der Zusammensetzung die Wechselwirkungen zwischen den Lösungsmitteln vernachlässigt werden. Dies verdeutlicht die Notwendigkeit experimenteller Daten zur Verteilung und Lösung von Radon in verschiedenem Gewebe.
Using (10.087±0.044)×109 𝐽/𝜓 events collected by the Beijing Spectrum III (BESIII) detector at the Beijing Electron Positron Collider II (BEPCII) collider, we search for the hyperon semileptonic decay Ξ−→Ξ0𝑒−¯𝜈𝑒. No significant signal is observed and the upper limit on the branching fraction ℬ(Ξ−→Ξ0𝑒−¯𝜈𝑒) is set to be 2.59×10−4 at 90% confidence level. This result is one order of magnitude more strict than the previous best limit.
Using 2.93 fb−1 of e+e− collision data collected with the BESIII detector at the center-of-mass energy 3.773 GeV, we perform the first amplitude analysis of the decay D+ → π+π0π0 and determine the relative magnitudes and phases of different intermediate processes. The absolute branching fraction of D+ → π+π0π0 is measured to be (2.888 ± 0.058stat. ± 0.069syst.)%. The dominant intermediate processes are D+ → a1(1260)+(→ ρ+π0) and D+ → *0ρ+, with branching fractions of (8.66 ± 1.04stat. ± 1.39syst.) × 10−3 and (9.70 ± 0.81stat. ± 0.53syst.) × 10−3, respectively.
The singly Cabibbo-suppressed decay D+s → K+π+π−π0 is observed by using a data set corresponding to an integrated luminosity of 6.32 fb−1 recorded by the BESIII detector at the centre-of-mass energies between 4.178 and 4.226 GeV. The first amplitude analysis of D+s → K+π+π−π0 reveals the sub-structures in this decay and determines the fractions and relative phases of different intermediate processes. The dominant intermediate process is D+s → K∗0ρ+, with a fit fraction of (40.5 ± 2.8stat. ± 1.5syst.)%. With the detection efficiency based on our amplitude analysis, the absolute branching fraction forD+s → K+π+π−π0 is measured to be (9.75 ± 0.54stat. ± 0.17syst.) × 10−3.