Refine
Year of publication
- 2010 (2875) (remove)
Document Type
- Article (1009)
- Doctoral Thesis (378)
- Part of Periodical (340)
- Book (338)
- Part of a Book (264)
- Review (145)
- Contribution to a Periodical (144)
- Working Paper (84)
- Report (71)
- Conference Proceeding (31)
Language
- German (1762)
- English (856)
- mis (105)
- Portuguese (62)
- French (32)
- Croatian (29)
- Multiple languages (12)
- Italian (7)
- dut (3)
- Spanish (3)
Keywords
- Mosambik (114)
- Mozambique (114)
- Moçambique (113)
- Filmmusik (96)
- Deutsch (80)
- Christentum (65)
- Bibel (63)
- bible (63)
- christianity (63)
- Literatur (48)
Institute
- Extern (316)
- Medizin (295)
- Präsidium (235)
- Gesellschaftswissenschaften (99)
- Biowissenschaften (98)
- Biochemie und Chemie (97)
- Physik (87)
- Geschichtswissenschaften (68)
- Geowissenschaften (59)
- Wirtschaftswissenschaften (55)
Letter from the President 4 ; Indigenous Bilingual Education in Vietnam: Initiatives and Lessons America’s Schools Can Learn From Eirini Gouleta 5 ; The Effects of Music on Spanish- Dominant Kindergarteners - Sandra B. Chong 10 ; Indigenous Bilingual Education “Essie’s Story” Insightful Words from an Old Teacher to Teachers Today - Chelsea Bergner, Northern Arizona University 14 ; Asian and Pacific Islanders Supporting Asian Immigrant Families of Children with Disabilities Effectively - Lusa Lo, Ed.D., University of
Massachusetts, Boston 16 ; Peace Corps, an undervalued source of bilingual support? - Brock Brady 19
Contributing to NABE News - Guidelines for Writers 2 ; Letter from the President 4 ; Conceptualizing a Schoolwide Bilingual Literacy Model: Closing the Achievement Gap through Systematic Formative Assessment - Doris Luft Baker 6 ; Asian and Pacific Islanders Asian American English Language Learners’ Identity Formation and Dynamic Transformation - Deoksoon Kim 10 ; Indigenous Bilingual Education Mother Tongue Education - Jon Reyhner, Northern Arizona University 12 ; Improving the Literacy Skills of Children and Young Adults - Leo Gómez 12
»Wie ist der Spazirgang durch Europa bekommen?« Mit dieser ungewöhnlichen Frage beschließt Johann Wolfgang Goethe seinen Brief, den er am 8. März 1803 an den Dichterfreund Friedrich Schiller richtet. Ungewöhnlich erscheint die Frage deshalb, weil Schiller bekanntermaßen nicht sonderlich viel reiste und die Grenzen des deutschen Territoriums zeitlebens nicht überschritt. Eine Italienische Reise, auf die sich Goethe Ende der 1780er Jahre begibt, oder ein Spaziergang nach Syrakus, wie ihn Johann Gottfried Seume im Jahr 1802 unternimmt, fehlen in Schillers Biographie. Doch in Goethes Brief ist auch von keiner Reise, sondern schlicht von Friedrich Schlegels neuer Zeitschrift Europa die Rede, deren erstes Heft im Februar 1803 erschienen war. Auskunft darüber, wie ihm dieser »Spazirgang […] bekommen« sei, gibt Schiller zwar nicht, aber es ist zu vermuten, dass er ihm sicher nicht missfallen hat. Denn im Beitrag »Literatur« erwähnt Schlegel unter anderem die »Schillerschen Trauerspiele«, die er zu »eine[r] Reihe von Versuchen poetischer Darstellungen auf dem Theater« rechnet, die »hoffen lassen, daß bald ein hinlängliches Fundament vorhanden seyn werde, um unter einer Direction, die der des Weimarischen ähnlich wäre, ein Theater zu gründen, das durchaus nur im Gebiete der schönen Kunst seine Existenz hätte […].« Dass um 1800 eine Zeitschrift gegründet wird, die programmatisch den Namen ›Europa‹ trägt, spricht für die Popularität des europäischen Gedankens, dessen Bedeutungshorizont kultur-, sozial- und ideengeschichtliche Perspektiven vereint.
2.1. Background & purpose The recent introduction of new technical innovations such as CT perfusion (CTP) and dual energy CT (DECT) increases the diagnostic abilities of CT for imaging of the head and neck (H&N). The aim of this work was to evaluate the role of CTP and DECT in head and neck imaging. The first part tests whether CTP can differentiate between malignant H&N tumors and surrounding muscle, and discusses the impact of arterial input selection and tumor region of interest (ROI) on CTP of H&N cancer. The second part of the study evaluates radiation dose and image quality of DECT of the H&N. Finally the use of DE derived weighted averaging to improve lesion delineation and image quality is discussed. 2.2. Patients and methods CT perfusion Retrospective analysis of CTP was done for a total number of 55 cases of H&N tumors. Perfusion parameters were calculated for 33 cases of squamous cell carcinoma (SCC) and compared to those of muscles. CTP parameters of 50 cases of H&N tumors calculated using different arterial input functions were compared. CTP was calculated for 28 SCC cases using the single dynamic CT section that shows maximal tumor dimension compared to using average values obtained from all tumor-containing dynamic CT sections. Dual energy CT of head and neck This prospective part of the study was further divided into 2 parts. In the first part 32 consecutive patients underwent DECT of the H&N and were compared to a standard single energy CT (SE) control group. Radiation doses were compared. Weighted-average images from raw data of the 2 DE tubes (weighting factor 0.3 from 80 kVp and 0.7 from 140 KVp) were compared to SE images. Image noise was compared at 5 anatomic levels. Two blinded readers compared subjective overall image quality on a 5-point grading scale. In the second part 35 proved SCC cases underwent DECT of the neck. Pure 140 kVp and 80 kVp image datasets as well as weighted-average images from raw data of the 2 DE tubes at weighting factors 0.3, 0.6, 0.8 (30%, 60% and 80% from 80 kVp raw data respectively) were reconstructed. Objective image noise, contrast to noise ratio (CNR) and subjective image quality were compared between the 5 image datasets. Results CT perfusion Tumor perfusion parameters were significantly higher than those of muscle (p <0.05). Significant high correlation with no significant differences between the means (p >0.05) were observed between perfusion parameters obtained using internal carotid artery (ICA) versus external carotid artery (ECA) and ipsilateral versus contralateral ICA. High correlation was observed between perfusion parameters calculated using one section with maximal tumor dimension and the average of multiple sections. Differences between the means were non significant, p values>0.05. The 95% limits of agreement between repeated measurements using average of multiple sections were slightly narrower for blood volume and permeability than those of repeated measurements using one section. Dual energy CT of head and neck CTDIvol was 12% lower with DE than SECT (p<0.0001). There were no significant differences in objective noise between DECT and SECT at any of the anatomic levels (p >0.05). There were no significant differences between DE- and SECT in attenuation measurements, all p values >0.05. No significant differences in subjective image quality scores were observed between DE- and SECT at any of the 5 anatomic levels (p >0.05). At weighting factor 0.6 the lesion CNR was significantly higher than at weighting factor 0.3 and at pure 140 kVp image dataset (p< 0.0001); while non significantly lower than at weighting factor 0.8 and pure 80 kVp (p=1.00). The 0.6 weighting factor was rated the best at subjective image quality and lesion delineation. 2.4. Conclusion In conclusion; this study demonstrated the ability of CTP to differentiate SCC from surrounding muscle tissue. The choice of arterial input selection has no significant impact on quantitative CTP of H&N tumors. CTP of SCC calculated from one section with maximal tumor dimensions and the average values from multiple sections are not significantly different. The second part of the study showed that DE scanning can be routinely used for H&N imaging; preserving high diagnostic image quality even when the radiation dose was lowered by 12%. Average weighting of DE raw data, with a weighting factor 0.6, results in significant improvement in both tumor delineation and image quality.
Ziel der vorliegenden experimentellen Untersuchung war die Erfassung und vergleichende Beurteilung der mechanischen Belastbarkeit sowie des Frakturverhaltens von karbonfaserverstärkten, keramischen und palladiumfreien Wurzelstiftsystemen. Des Weiteren galt es, die Ergebnisse im Vergleich zum Permador®-Stift, dessen Bewährung in einer vorangegangenen klinischen Untersuchung nachgewiesen wurde, und zu wurzelgefüllten Zähnen zu überprüfen. Gegenstand der Untersuchung waren der palladiumhaltige Permador®-Stift, die palladiumfreien Stiftaufbausysteme AF1, ER® Pt-IR, die keramischen Stifte Cerapost®, Celay® Alumina und Celay® Zirkonia sowie der Karbonfaserstift Composipost®. Als Kontrollgruppe dienten wurzelgefüllte, nicht stiftversorgte Wurzeln. Um die Streuung der Messwerte, die durch die individuell unterschiedliche Dimensionierung und Morphologie von extrahierten natürlichen Frontzähnen beeinflusst werden, zu minimieren, fanden künstliche Zähne aus dem lichthärtenden BisGMAKomposit Estilux hybrid VS posterior (Heraeus Kulzer, Wehrheim/Ts.), Verwendung. Dessen Elastizitätsmodul beträgt nach Aushärtung 19.000 MPa und entspricht somit dem Wert des natürlichen Dentins. Die Herstellung der Wurzeln, Aufbauten und Kronen fand mit sogenannten Modeln statt, wodurch die Herstellung identischer Prüfkörper gewährleistet wurde. Als Aufbaumaterial fand für die metallischen Stiftsysteme ein Phantom-Metall, für das Cerapost®- und Composipost®-System ein Komposit und für die kopiergefrästen Systeme Celay® Alumina und Celay® Zirkonia-Keramik Verwendung. Sämtliche Stiftverankerungen wurden, nach Konditionierung mit dem Rocatec®-Verfahren, mit Panavia® 21 in den Wurzeln zementiert. Im Anschluss erfolgte die Zementierung standardisierter Kronen aus Phantommetall auf allen Wurzeln. Die zyklische Wechselbelastung (1,2x106 Zyklen; 1,4 Hz und 30 N) wurde im Willytec-Kausimulator Version 3.1. (Fa. Willytec, München) vorgenommen. Die Simulation der Wurzelhaut für die Wechsel- und die Bruchbelastung wurde durch Einbettung der Wurzeln in einem Elastomer (Permadyne® Garant; Espe, Seefeld) vorgenommen. In einer Universal-Prüfmaschine (Zwicki 1120; Zwick, Ulm) (Vorschubgeschwindigkeit 0,5 mm/min) wurden die Versuchszähne palatinal, 2 Millimeter unterhalb der Inzisalkante, unter einem Winkel von 135° bis zum Bruch der Wurzel belastet. Hinsichtlich der Bruchlast ergaben die Medianwerte folgende Resultate: Metallstifte: Permador®: 475,4 N; AF1: 444,7 N; ER Pt-Ir: 422,4 N. Der KRUSKAL-WALLIS-Test mit BONFERRONI-Korrektur (p ≤ 0,05) zeigte keine signifikanten Unterschiede zwischen diesen drei Stiftsystemen einerseits und der Kontrollgruppe andererseits. Für die keramischen Stifte wurden 432,2 N [Celay® Alumina], 488,8 N [Celay® Zirkonia] bzw. 416,4 N [Cerapost®] und für den Karbonfaserstift [Composipost®] 515,7 N ermittelt. Bei der Kontrollgruppe trat eine Bruchlast von 363,4 N auf. Bezüglich der Bruchlastwerte lagen unter Berücksichtigung des BONFERRONI-Tests bei der statistischen Datenanalyse zwischen dem kopiergefrästen Keramikstiftaufbau Celay® Zirkonia aus zirkoniumoxidverstärkten Al2O3 einerseits bzw. dem Karbonfaserstift Composipost® und der Kontrollgruppe andererseits signifikante Unterschiede vor (p ≤ 0,05). Die ermittelten Distanzen zwischen Kraftangriffspunkt und den oberen Bruchspaltenden ergaben Medianwerte von 8,0 mm bis 11,1 mm auf der vestibulären Seite und 7,6 mm bis 14,7 mm auf der palatinalen Seite der Wurzeloberfläche. Bezüglich der Distanzen der Frakturverläufe lagen unter Berücksichtigung des BONFERRONI-Tests bei der statistischen Datenanalyse nur palatinal zwischen dem Cerapost®-Stift einerseits und dem Celay® Alumina-Stift und der Kontrollgruppe andererseits signifikante Unterschiede vor. Die vorliegende Studie zeigt, dass hinsichtlich der Bruchlastwerte nach dynamischer Belastung der Karbonfaserstift Composipost® und, bei hohen ästhetischen Ansprüchen, der kopiergefräste Keramikstift Celay® Zirkonia als interessante Alternative zum klinisch bewährten Permador®-Stift zu sehen sind. Des Weiteren zeigt die Untersuchung, dass sich die Verwendung palladiumfreier Stiftsysteme nicht nachteilig auf das Bruchverhalten nach dynamischer Belastung auswirkt.