Refine
Year of publication
- 2013 (101) (remove)
Document Type
- Article (30)
- Doctoral Thesis (21)
- Conference Proceeding (15)
- Master's Thesis (15)
- Bachelor Thesis (10)
- Contribution to a Periodical (4)
- Book (3)
- Part of Periodical (3)
Has Fulltext
- yes (101)
Is part of the Bibliography
- no (101)
Keywords
- Synchrotron (2)
- (F)EBID (1)
- ALICE experiment (1)
- Aktivierungsmethode (1)
- Akustik (1)
- Beauty production (1)
- Boltzmann equation (1)
- CBM (1)
- Chiral perturbation theory (1)
- Chiral symmetry (1)
Institute
- Physik (101) (remove)
The QGP that might be created in ultrarelativistic heavy-ion collisions is expected to radiate thermal dilepton radiation. However, this thermal dilepton radiation interferes with dileptons originating from hadron decays. In the invariant mass region between the f and J=y peak (1GeV <= M l+l <=. 3GeV) the most substantial background of hadron decays originates from correlated DD¯ -meson decays. We evaluate this background using a Langevin simulation for charm quarks. As background medium we utilize the well-tested UrQMD-hybrid model. The required drag and diffusion coefficients are taken from a resonance approach. The decoupling of the charm quarks from the hot medium is performed at a temperature of 130MeV and as hadronization mechanism a coalescence approach is chosen. This model for charm quark interactions with the medium has already been successfully applied to the study of the medium modification and the elliptic flow at FAIR, RHIC and LHC energies. In this proceeding we present our results for the dilepton radiation from correlated D¯D decays at RHIC energy in comparison to PHENIX measurements in the invariant mass range between 1 and 3 GeV using different interaction scenarios. These results can be utilized to estimate the thermal QGP radiation.
Development of prototype components for the Silicon Tracking System of the CBM experiment at FAIR
(2013)
The CBM experiment at future accelerator facility FAIR will investigate the properties of nuclear matter under extreme conditions. The experimental programm is different from the heavy-ion experiments at RHIC (BNL) and LHC (CERN) that create nuclear matter at high temperatures. In contrast, the study of the QCD phase diagram in the region of the highest net baryon densities and moderate temperatures that is weakly explored will be performed with high precision. For this, collisions of different heavy-ion beams at the energies of 10–45GeV/nucleon with nuclear target will be measured.
The physics programme of the CBM experiment includes measurement of both rare probes and bulk observables that originate from various phases of a nucleus-nucleus collision. In particular, decay of particles with charm quarks can be registered by reconstructing the decay vertex detached from the primary interaction point by several hundreds of micrometers (e.g., decay length c Tau = 123 µm for D0 meson). For this, precise tracking and full event reconstruction with up to 600 charged particle tracks per event within acceptance are required. Other rare probes require operation at interaction rate of up to 10MHz. The detector system that performs tracking has to provide high position resolution on the order of 10 µm, operate at high rates and have radiation tolerant design with low material budget.
The Silicon Tracking System (STS) is being designed for charged-particle tracking in a magnetic field. The system consists of eight tracking station located in the aperture of a dipole magnet with 1T field. For tracks with momentum above 1GeV, momentum resolution of such a system is expected to be about 1%. In order to fulfill this task, thorough optimization of the detector design is required. In particular, minimal material budget has to be achieved.
Production of a detector module requires research and development activities with respect to the module components and their integration. A detector module is a basic functional unit that includes a sensor, an analogue microcable and frontend electronics mounted on a support structure. The objective of the thesis is to perform quality assurance tests of the prototype module components in order to validate the concept of the detector module and to demonstrate its operation using radioactive sources and particle beams.
Double-sided silicon microstrip detectors have been chosen as sensor technology for the STS because of the combination of a good spatial resolution, two-dimensional coordinate measurement achieved within low material budget (0.3%X0), high readout speed and sufficient radiation tolerance. Several generations of double-sided silicon microstrip sensors have been manufactured in order to explore the radiation hard design features and the concept of a large-area sensor compatible with ladder-type structure of the detector module. In particular, sensors with double metal layer on both sides and active area of 62×62mm2 have been produced. Electrical characterization of the sensors has been performed in order to establish the overall operability as well as to extract the device parameters. Current-voltage, capacitance-voltage characteristics and interstrip parameters have been measured.
Readout of the sensors has been done using self-triggering front-end electronics. A front-end board has been developed based on the n-XYTER readout chip with data driven architecture and capable of operating at 32MHz readout rate. The front-end board included an external analog-to-digital converter (ADC). Calibration of the ADC has been performed using both 241Am X-ray source and external pulse generator. Threshold calibration and investigation of temperature dependence of chip parameters has been carried out.
Low-mass support structures have been developed using carbon fibre that has the rigidity to hold the detector modules and introduce minimal Coulomb scattering of the particle tracks. Analogue microcables have been produced with aluminium traces on a polyimide substrate, thus combining good electrical connection with low material budget. Microcable structure includes several layers optimized for low trace capacitance and thus low-noise performance.
A demonstrator tracking telescope has been constructed and operated in several beam tests including 2.5GeV proton beam at COSY synchrotron (Jülich). Three tracking stations have been complemented with several beam hodoscopes. Analysis of the beam data has yielded information on analogue and timing response, beam profile. Tracking and alignment information has been obtained. Beam stability has been evaluated using specially developed monitoring tools.
As a result of conducted studies, performance of the module components have been evaluated and requirements to the detector module have been formulated. Practical suggestions have been made with respect to the structure of the detector module, whereas precise definition of the final detector module design was outside of the scope of this thesis.
Heterodyne array receivers are employed in radio astronomy to reduce the observing time needed for mapping extended sources. One of the main factors limiting the amount of pixels in terahertz receivers is the difficulty of generating a sufficient amount of local oscillator power. Another challenge is efficient diplexing and coupling of local oscillator and signal power to the detectors. These problems are attacked in this dissertation by proposing the application of two vacuum electronic terahertz amplifier types for the amplification of the LO-signal and by introducing a new method for finding the defects in a quasioptical diplexer.
A traveling wave tube (TWT) design based on a square helix slow wave structure (SWS) at 825 GHz is introduced. It exhibits a simulated small-signal gain of 18.3 dB and a 3-dB bandwidth of 69 GHz. In order to generate LO-power at even higher frequencies, the operation of an 850-GHz square helix TWT as a frequency doubler has been studied. A simulated conversion efficiency of 7% to 1700 GHz, comparable with the state-of-art solid-state doublers, has been achieved for an input power of 25 mW.
The other amplifier type discussed in this work is a 1-THz cascade backward wave amplifier based on a double corrugated waveguide SWS. Specifically, three input/output coupler types between a rectangular waveguide and the SWS are presented. The structures have been realized with microfabrication, and the results of loss measurements at 1 THz will be shown.
Diplexing of the LO- and signal beams is often performed with a Martin-Puplett interferometer. Misalignment and deformation of the quasioptical components causes the polarization state of the output signal to be incorrect, which leads to coupling losses. A ray-tracing program has been developed for studying the influence of such defects. The measurement results of the diplexer of a multi-pixel terahertz receiver operated at the APEX telescope have been analyzed with the program, and the results are presented. The program allows the quasioptical configuration of the diplexer to be corrected in order to obtain higher receiver sensitivity.
We study the impact of nonequilibrium effects on the relevant signals within a chiral fluid dynamics model including explicit propagation of the Polyakov loop. An expanding heat bath of quarks is coupled to the Langevin dynamics of the order parameter fields. The model is able to describe relaxational processes, including critical slowing down and the enhancement of soft modes near the critical point. At the first-order phase transition we observe domain formation and phase coexistence in the sigma and Polyakov loop field leading to a significant amount of clumping in the energy density. This effect gets even more pronounced if we go to systems at finite baryon density. Here the formation of high-density clusters could provide an important observable signal for upcoming experiments at FAIR and NICA.We conclude that improving our understanding of dynamical symmetry breaking is important to give realistic estimates for experimental observables connected to the QCD phase transition.
In der vorliegenden Arbeit wurden mikroskopische Studien zur Äquilibrierung von partonischer und hadronischer Materie im Rahmen einer Nichtgleichgewichts-Transporttheorie durchgeführt, die sowohl hadronische als partonische Freiheitsgrade enthält und den Übergang zwischen beiden Phasen dynamisch beschreibt. Des Weiteren wurden die thermischen Eigenschaften des Gleichgewichtszustandes der stark wechselwirkenden Materie untersucht, insbesondere Fluktuationen in der Teilchenzahl wie auch höhere Momente von Observablen und deren Verhältnisse. Besonderes Interesse galt dabei den Transportkoeffizienten wie Scher- und Volumenviskosität sowie der elektrischen Leitfähigkeit.
Die Methode der Nichtgleichgewichts-Green'schen Funktionen - initiiert von Schwinger sowie Kadanoff und Baym - wurde vorgestellt um hochenergetische Kern-Kern Kollisionen zu beschreiben. Weiterhin wurde der Schwinger-Keldysh Formalismus benutzt um im Sinne einer Zweiteilchen-irrediziblen Näherung (2PI) die Dynamik von 'resummierten' Propagatoren und Kopplungen in konsistenter Weise zu beschreiben. Des Weiterhin wurden generalisierte Transportgleichungen auf der Basis der Kadanoff-Baym Gleichungen (in Phasenraumdarstellung) abgeleitet und ein Testteilchenverfahren zur Lösung dieser Gleichungen vorgestellt. Damit wurde der formale Rahmen der Parton-Hadron-String Dynamik (PHSD) abgesteckt.
Das PHSD Transportmodell wurde sodann für die Lösung der expliziten Fragestellungen in dieser Arbeit verwendet. Die 'Eingangsgrößen' des Modells wurden in Kapitel 3 aufgeführt. Weiterhin wurde aufgezeigt, dass das Transportmodell alle Phasen einer relativistischen Schwerionenkollision konsistent beschreibt, d.h. angefangen von den primären harten Stoßprozessen und der Bildung von 'Strings' zur Formierung einer partonischen Phase, den Wechselwirkungen in dieser Phase sowie die
dynamische Beschreibung der Hadronisierung. Weiterhin enthält das Modell zudem die hadronischen Endzustandswechselwirkungen bis zum Ausfrieren der hadronischen Freiheitsgrade bei geringer Dichte. ...
We derive the Polyakov-loop thermodynamic potential in the perturbative approach to pure SU(3) Yang-Mills theory. The potential expressed in terms of the Polyakov loop in the fundamental representation corresponds to that of the strong-coupling expansion, of which the relevant coefficients of the gluon energy distribution are specified by characters of the SU(3) group. At high temperature, the potential exhibits the correct asymptotic behavior, whereas at low temperature, it disfavors gluons as appropriate dynamical degrees of freedom. To quantify the Yang-Mills thermodynamics in confined phase, we introduce a hybrid approach which matches the effective gluon potential to that of glueballs, constrained by the QCD trace anomaly in terms of dilaton fields.
Ziel dieser Arbeit war, die Reaktion von biologischen Gewebeproben auf dünn- und dicht-ionisierende Strahlung zu evaluieren. Dafür wurden die Gewebeproben konventioneller Röntgenstrahlung sowie einem ausgedehnten 12C-Ionen Bragg-Peak ausgesetzt. Zur Bestrahlung der biologischen Proben mit 12C wurde mit dem GSI-eigenen Simulationsprogramm TRiP98 ein Tiefendosisprofil eines ausgedehnten Bragg-peaks erstellt. Ein weiteres Ziel dieser Arbeit war, dieses Tiefendosisprofil mit drei anderen Simulationsprogrammen (ATIMA, MCHIT, TRIM) zu reproduzieren und zu vergleichen.
ATIMA und TRIM sind allgemeine Programme für den Energieverlust von Ionen in Materie. Sie können das von TRiP98 berechnetet Tiefendosisprofil nur ungenügend reproduzieren, da sie aufgrund fehlender Fragmentierung ein linear ansteigendes Tiefendosisprofil berechnen. Das Monte Carlo-Programm MCHIT, welches speziell für die Wechselwirkung von Ionen mit Materie in medizinischer Anwendung entwickelt wurde, zeigt die beste Übereinstimmung mit der TRiP98-Referenzkurve. Bis auf eine leicht höhere Durchschnittsdosis um 0.1 Gy konnte das Tiefendosisprofil nahezu exakt reproduziert werden.
Die biologischen Proben bestanden aus Schnittkulturen gesunder Maus-Lebern und Explantatkulturen gesunder Maus-Pankreata, um Nebenwirkungen ionisierender Strahlen abzuschätzen. Zusätzlich wurde die Reaktion auf 12C-Bestrahlung in neoplastischem Lebergewebe transgener c-myc/TGF-α Mäuse mit induzierbarem Lebertumor bestimmt. Um eine mögliche Tageszeitabhängigkeit der Gewebereaktion auf die Bestrahlung zu untersuchen, wurden die Schnitt- und Explantatkulturen zu zwei unterschiedlichen Tageszeiten präpariert: zur Mitte des subjektiven Tages und zur Mitte der subjektiven Nacht.
Die Präparate wurden für mehrere Tage auf einer Membran an einer Grenzschicht von Flüssigkeit und Luft kultiviert. Leber- und Pankreaskulturen gesunder C3H wildtyp Mäuse wurden mit einer Dosis von 2 Gy, 5 Gy oder 10 Gy Röntgenstrahlen bestrahlt. Leber- und Pankreaskulturen transgener Mäuse wurden mit ausgedehnten C-Ionen Bragg Peaks gleicher Dosen bestrahlt. Als Kontrolle dienten unbestrahlte Proben. Alle Proben wurden 1 h bzw. 24 h nach der Bestrahlung fixiert und immunhistochemisch auf Marker für Proliferation (Ki67), Apoptose (Caspase3) und DNA- Doppelstrangbrüche (γH2AX) untersucht.
Während die Pankreas-Präparate im Hinblick auf die untersuchten Parameter leider keine auswertbaren Ergebnisse ergaben, zeigten die untersuchten Parameter im gesunden Lebergewebe deutliche Tag-Nacht Unterschiede: die Proliferationsrate war zur Mitte des subjektiven Tages signifikant höher als zur Mitte der subjektiven Nacht. Umgekehrt waren die Raten für DNA-Doppelstrangbrüche zur Mitte der subjektiven Nacht signifikant erhöht. Diese Tag-Nacht Unterschiede ließen sich in neoplastischem Lebergewebe nicht nachweisen. Unabhängig von der Art und Dosis, hatte die Bestrahlung im gesunden Lebergewebe keinen Einfluss auf die untersuchten Parameter. In neoplastischem Lebergewebe hingegen wird die Rate an DNA-Doppelstrangbrüchen durch eine Bestrahlung dosisabhängig erhöht.
Die Auswirkungen ionisierender Strahlen auf das circadiane Uhrwerk wurden in Gewebeproben transgener Per2luc-Mäuse überprüft. Per2luc-Mäuse exprimieren das Enzym Luziferase unter der Kontrolle des Promoters von Per2, einem wichtigen Bestandteil des circadianen Uhrwerks. Daher erlaubt die Analyse dieser Tiere, den circadianen Rhythmus des molekularen Uhrwerks in Leber und anderen Geweben durch Messung der Luziferase-Aktivität in Echtzeit aufzuzeichnen. Wie in Leber- und Nebennierenkulturen dieser Tiere gezeigt werden konnte, führten ioniserende Strahlen dosisabhängig zu einem Phasenvorsprung des circadianen Uhrwerks.
Die Ergebnisse erlauben die Schlussfolgerung, dass ionisierende Strahlen das circadiane Uhrwerk verstellen, Proliferation und Apoptose in gesundem Lebergewebe jedoch kaum beeinflussen.