Refine
Year of publication
Document Type
- Article (30886)
- Part of Periodical (11923)
- Book (8320)
- Doctoral Thesis (5737)
- Part of a Book (3723)
- Working Paper (3388)
- Review (2878)
- Contribution to a Periodical (2369)
- Preprint (2226)
- Report (1544)
Language
- German (42613)
- English (29733)
- French (1067)
- Portuguese (723)
- Multiple languages (314)
- Croatian (302)
- Spanish (301)
- Italian (195)
- mis (174)
- Turkish (148)
Is part of the Bibliography
- no (75895) (remove)
Keywords
- Deutsch (1038)
- Literatur (809)
- taxonomy (768)
- Deutschland (543)
- Rezension (491)
- new species (453)
- Frankfurt <Main> / Universität (341)
- Rezeption (325)
- Geschichte (292)
- Übersetzung (271)
Institute
- Medizin (7779)
- Präsidium (5235)
- Physik (4594)
- Wirtschaftswissenschaften (2710)
- Extern (2661)
- Gesellschaftswissenschaften (2378)
- Biowissenschaften (2198)
- Biochemie und Chemie (1978)
- Frankfurt Institute for Advanced Studies (FIAS) (1775)
- Center for Financial Studies (CFS) (1632)
The brain is a highly dynamic and variable system: when the same stimulus is presented to the same animal on the same day multiple times, the neural responses show high trial-to-trial variability. In addition, even in the absence of sensory stimulation neural recordings spontaneously show seemingly random activity patterns. Evoked and spontaneous neural variability is not restricted to activity but is also found in structure: most synapses do not survive for longer than two weeks and even those that do show high fluctuations in their efficacy.
Both forms of variability are further affected by stochastic components of neural processing such as frequent transmission failure. At present it is unclear how these observations relate to each other and how they arise in cortical circuits.
Here, we will investigate how the self-organizational processes of neural circuits affect the high variability in two different directions: First, we will show that recurrent dynamics of self-organizing neural networks can account for key features of neural variability. This is achieved in the absence of any intrinsic noise sources by the neural network models learning a predictive model of their environment with sampling-like dynamics. Second, we will show that the same self-organizational processes can compensate for intrinsic noise sources. For this, an analytical model and more biologically plausible models are established to explain the alignment of parallel synapses in the presence of synaptic failure.
Both modeling studies predict properties of neural variability, of which two are subsequently tested on a synapse database from a dense electron microscopy reconstruction from mouse somatosensory cortex and on multi-unit recordings from the visual cortex of macaque monkeys during a passive viewing task. While both analyses yield interesting results, the predicted properties were not confirmed, guiding the next iteration of experiments and modeling studies.
kurz und kn@pp news : Nr. 38
(2016)
Amines are potentially important for atmospheric new particle formation, but their concentrations are usually low with typical mixing ratios in the pptv range or even smaller. Therefore, the demand for highly sensitive gas-phase amine measurements has emerged in the last several years. Nitrate chemical ionization mass spectrometry (CIMS) is routinely used for the measurement of gasphase sulfuric acid in the sub-pptv range. Furthermore, extremely low volatile organic compounds (ELVOCs) can be detected with a nitrate CIMS. In this study we demonstrate that a nitrate CIMS can also be used for the sensitive measurement of dimethylamine (DMA, (CH3/2NH) using the NO3−•(HNO3)1 − 2• (DMA) cluster ion signal. Calibration measurements were made at the CLOUD chamber during two different measurement campaigns. Good linearity between 0 and ~120 pptv of DMA as well as a sub-pptv detection limit of 0.7 pptv for a 10 min integration time are demonstrated at 278K and 38% RH.
We present a compact and versatile cryofocusing– thermodesorption unit, which we developed for quantitative analysis of halogenated trace gases in ambient air. Possible applications include aircraft-based in situ measurements, in situ monitoring and laboratory operation for the analysis of flask samples. Analytes are trapped on adsorptive material cooled by a Stirling cooler to low temperatures (e.g. -80°C) and subsequently desorbed by rapid heating of the adsorptive material (e.g. 200°C). The set-up involves neither the exchange of adsorption tubes nor any further condensation or refocusing steps. No moving parts are used that would require vacuum insulation. This allows for a simple and robust design. Reliable operation is ensured by the Stirling cooler, which neither contains a liquid refrigerant nor requires refilling a cryogen. At the same time, it allows for significantly lower adsorption temperatures compared to commonly used Peltier elements. We use gas chromatography – mass spectrometry (GC–MS) for separation and detection of the preconcentrated analytes after splitless injection. A substance boiling point range of approximately -80 to +150°C and a substance mixing ratio range of less than 1 ppt (pmol mol−1)to more than 500 ppt in preconcentrated sample volumes of 0.1 to 10 L of ambient air is covered, depending on the application and its analytical demands. We present the instrumental design of the preconcentration unit and demonstrate capabilities and performance through the examination of analyte breakthrough during adsorption, repeatability of desorption and analyte residues in blank tests. Examples of application are taken from the analysis of flask samples collected at Mace Head Atmospheric Research Station in Ireland using our laboratory GC–MS instruments and by data obtained during a research flight with our in situ aircraft instrument GhOSTMS (Gas chromatograph for the Observation of Tracers – coupled with a Mass Spectrometer).
We present a compact and versatile cryofocusing–thermodesorption unit, which we developed for quantitative analysis of halogenated trace gases in ambient air. Possible applications include aircraft-based in situ measurements, in situ monitoring and laboratory operation for the analysis of flask samples. Analytes are trapped on adsorptive material cooled by a Stirling cooler to low temperatures (e.g. −80 °C) and subsequently desorbed by rapid heating of the adsorptive material (e.g. +200 °C). The set-up involves neither the exchange of adsorption tubes nor any further condensation or refocusing steps. No moving parts are used that would require vacuum insulation. This allows for a simple and robust design. Reliable operation is ensured by the Stirling cooler, which neither contains a liquid refrigerant nor requires refilling a cryogen. At the same time, it allows for significantly lower adsorption temperatures compared to commonly used Peltier elements. We use gas chromatography – mass spectrometry (GC–MS) for separation and detection of the preconcentrated analytes after splitless injection. A substance boiling point range of approximately −80 to +150 °C and a substance mixing ratio range of less than 1 ppt (pmol mol−1) to more than 500 ppt in preconcentrated sample volumes of 0.1 to 10 L of ambient air is covered, depending on the application and its analytical demands. We present the instrumental design of the preconcentration unit and demonstrate capabilities and performance through the examination of analyte breakthrough during adsorption, repeatability of desorption and analyte residues in blank tests. Examples of application are taken from the analysis of flask samples collected at Mace Head Atmospheric Research Station in Ireland using our laboratory GC–MS instruments and by data obtained during a research flight with our in situ aircraft instrument GhOST-MS (Gas chromatograph for the Observation of Tracers – coupled with a Mass Spectrometer).
Knowledge about mass discrimination effects in a chemical ionization mass spectrometer (CIMS) is crucial for quantifying, e.g., the recently discovered extremely low volatile organic compounds (ELVOCs) and other compounds for which no calibration standard exists so far. Here, we present a simple way of estimating mass discrimination effects of a nitrate-based chemical ionization atmospheric pressure interface time-of-flight (CI-APi-TOF) mass spectrometer. Characterization of the mass discrimination is achieved by adding different perfluorinated acids to the mass spectrometer in amounts sufficient to deplete the primary ions significantly. The relative transmission efficiency can then be determined by comparing the decrease of signals from the primary ions and the increase of signals from the perfluorinated acids at higher masses. This method is in use already for PTR-MS; however, its application to a CI-APi-TOF brings additional difficulties, namely clustering and fragmentation of the measured compounds, which can be treated with statistical analysis of the measured data, leading to selfconsistent results. We also compare this method to a transmission estimation obtained with a setup using an electrospray ion source, a high-resolution differential mobility analyzer and an electrometer, which estimates the transmission of the instrument without the CI source. Both methods give different transmission curves, indicating non-negligible mass discrimination effects of the CI source. The absolute transmission of the instrument without the CI source was estimated with the HR-DMA method to plateau between the m=z range of 127 and 568 Th at around 1.5 %; however, for the CI source included, the depletion method showed a steady increase in relative transmission efficiency from the m=z range of the primary ion (mainly at 62 Th) to around 550 Th by a factor of around 5. The main advantages of the depletion method are that the instrument is used in the same operation mode as during standard measurements and no knowledge of the absolute amount of the measured substance is necessary, which results in a simple setup.
Knowledge about mass discrimination effects in a chemical ionization mass spectrometer (CIMS) is crucial for quantifying, e.g., the recently discovered extremely low volatile organic compounds (ELVOCs) and other compounds for which no calibration standard exists so far. Here, we present a simple way of estimating mass discrimination effects of a nitrate-based chemical ionization atmospheric pressure interface time-of-flight (CI-APi-TOF) mass spectrometer. Characterization of the mass discrimination is achieved by adding different perfluorinated acids to the mass spectrometer in amounts sufficient to deplete the primary ions significantly. The relative transmission efficiency can then be determined by comparing the decrease of signals from the primary ions and the increase of signals from the perfluorinated acids at higher masses. This method is in use already for PTR-MS; however, its application to a CI-APi-TOF brings additional difficulties, namely clustering and fragmentation of the measured compounds, which can be treated with statistical analysis of the measured data, leading to self-consistent results. We also compare this method to a transmission estimation obtained with a setup using an electrospray ion source, a high-resolution differential mobility analyzer and an electrometer, which estimates the transmission of the instrument without the CI source. Both methods give different transmission curves, indicating non-negligible mass discrimination effects of the CI source. The absolute transmission of the instrument without the CI source was estimated with the HR-DMA method to plateau between the m∕z range of 127 and 568 Th at around 1.5 %; however, for the CI source included, the depletion method showed a steady increase in relative transmission efficiency from the m∕z range of the primary ion (mainly at 62 Th) to around 550 Th by a factor of around 5. The main advantages of the depletion method are that the instrument is used in the same operation mode as during standard measurements and no knowledge of the absolute amount of the measured substance is necessary, which results in a simple setup.