Refine
Year of publication
Document Type
- Preprint (572)
- Article (364)
- Doctoral Thesis (1)
Language
- English (937)
Has Fulltext
- yes (937)
Is part of the Bibliography
- no (937)
Keywords
- Heavy Ion Experiments (18)
- Hadron-Hadron scattering (experiments) (11)
- LHC (9)
- Heavy-ion collision (6)
- ALICE experiment (4)
- Hadron-Hadron Scattering (4)
- Heavy Ions (4)
- Quark-Gluon Plasma (4)
- Jets and Jet Substructure (3)
- pp collisions (3)
Institute
- Physik (917)
- Frankfurt Institute for Advanced Studies (FIAS) (847)
- Informatik (813)
- Geowissenschaften (19)
- Informatik und Mathematik (3)
- Starker Start ins Studium: Qualitätspakt Lehre (3)
- Hochschulrechenzentrum (2)
- Medizin (1)
The exact mechanisms for new particle formation (NPF) under different boundary layer conditions are not known yet. One important question is if amines and sulfuric acid lead to efficient NPF in the atmosphere. Furthermore, it is not clear to what extent highly oxidized organic molecules (HOM) are involved in NPF. We conducted field measurements at a rural site in central Germany in the proximity of three larger dairy farms to investigate if there is a connection between NPF and the presence of amines and/or ammonia due to the local emissions from the farms. Comprehensive measurements using a nitrate Chemical Ionization-Atmospheric Pressure interface-Time Of Flight (CI-APi-TOF) mass spectrometer, a Proton Transfer Reaction-Mass Spectrometer (PTR-MS), particle counters and Differential Mobility Analyzers (DMAs) as well as measurements of trace gases and meteorological parameters were performed. It is shown that the nitrate CI-APi-TOF is suitable for sensitive measurements of sulfuric acid, amines, a nitrosamine, ammonia, iodic acid and HOM. NPF was found to correlate with sulfuric acid, while an anti-correlation with RH, amines and ammonia is observed. The anti-correlation between NPF and amines could be due to the efficient uptake of these compounds by nucleating clusters and small particles. Much higher HOM dimer (C19/C20 compounds) concentrations during the night than during the day indicate that these HOM do not efficiently self-nucleate as no night-time NPF is observed. Observed iodic acid probably originates from an iodine-containing reservoir substance but the iodine signals are very likely too low to have a significant effect on NPF.
Knowledge about mass discrimination effects in a chemical ionization mass spectrometer (CIMS) is crucial for quantifying, e.g., the recently discovered extremely low volatile organic compounds (ELVOCs) and other compounds for which no calibration standard exists so far. Here, we present a simple way of estimating mass discrimination effects of a nitrate-based chemical ionization atmospheric pressure interface time-of-flight (CI-APi-TOF) mass spectrometer. Characterization of the mass discrimination is achieved by adding different perfluorinated acids to the mass spectrometer in amounts sufficient to deplete the primary ions significantly. The relative transmission efficiency can then be determined by comparing the decrease of signals from the primary ions and the increase of signals from the perfluorinated acids at higher masses. This method is in use already for PTR-MS; however, its application to a CI-APi-TOF brings additional difficulties, namely clustering and fragmentation of the measured compounds, which can be treated with statistical analysis of the measured data, leading to self-consistent results. We also compare this method to a transmission estimation obtained with a setup using an electrospray ion source, a high-resolution differential mobility analyzer and an electrometer, which estimates the transmission of the instrument without the CI source. Both methods give different transmission curves, indicating non-negligible mass discrimination effects of the CI source. The absolute transmission of the instrument without the CI source was estimated with the HR-DMA method to plateau between the m∕z range of 127 and 568 Th at around 1.5 %; however, for the CI source included, the depletion method showed a steady increase in relative transmission efficiency from the m∕z range of the primary ion (mainly at 62 Th) to around 550 Th by a factor of around 5. The main advantages of the depletion method are that the instrument is used in the same operation mode as during standard measurements and no knowledge of the absolute amount of the measured substance is necessary, which results in a simple setup.
Knowledge about mass discrimination effects in a chemical ionization mass spectrometer (CIMS) is crucial for quantifying, e.g., the recently discovered extremely low volatile organic compounds (ELVOCs) and other compounds for which no calibration standard exists so far. Here, we present a simple way of estimating mass discrimination effects of a nitrate-based chemical ionization atmospheric pressure interface time-of-flight (CI-APi-TOF) mass spectrometer. Characterization of the mass discrimination is achieved by adding different perfluorinated acids to the mass spectrometer in amounts sufficient to deplete the primary ions significantly. The relative transmission efficiency can then be determined by comparing the decrease of signals from the primary ions and the increase of signals from the perfluorinated acids at higher masses. This method is in use already for PTR-MS; however, its application to a CI-APi-TOF brings additional difficulties, namely clustering and fragmentation of the measured compounds, which can be treated with statistical analysis of the measured data, leading to selfconsistent results. We also compare this method to a transmission estimation obtained with a setup using an electrospray ion source, a high-resolution differential mobility analyzer and an electrometer, which estimates the transmission of the instrument without the CI source. Both methods give different transmission curves, indicating non-negligible mass discrimination effects of the CI source. The absolute transmission of the instrument without the CI source was estimated with the HR-DMA method to plateau between the m=z range of 127 and 568 Th at around 1.5 %; however, for the CI source included, the depletion method showed a steady increase in relative transmission efficiency from the m=z range of the primary ion (mainly at 62 Th) to around 550 Th by a factor of around 5. The main advantages of the depletion method are that the instrument is used in the same operation mode as during standard measurements and no knowledge of the absolute amount of the measured substance is necessary, which results in a simple setup.
A new method for size-resolved chemical analysis of nucleation mode aerosol particles (size range from ∼10 to ∼30 nm) is presented. The Thermal Desorption Differential Mobility Analyzer (TD-DMA) uses an online, discontinuous principle. The particles are charged, a specific size is selected by differential mobility analysis and they are collected on a filament by electrostatic precipitation. Subsequently, the sampled mass is evaporated in a clean carrier gas and analyzed by a chemical ionization mass spectrometer. Gas-phase measurements are performed with the same mass spectrometer during the sampling of particles. The characterization shows reproducible results, with a particle size resolution of 1.19 and the transmission efficiency for 15 nm particles being slightly above 50 %. The signal from the evaporation of a test substance can be detected starting from 0.01 ng and shows a linear response in the mass spectrometer. Instrument operation in the range of pg m−3 is demonstrated by an example measurement of 15 nm particles produced by nucleation from dimethylamine, sulfuric acid and water.
A new method for size resolved chemical analysis of nucleation mode aerosol particles (size range from ~10 to ~30 nm) is presented. The Thermal Desorption Differential Mobility Analyzer (TD-DMA) uses an online, discontinuous principle. The particles are charged, a specific size is selected by differential mobility analysis and they are collected on a filament by electrostatic precipitation. Subsequently, the sampled mass is evaporated in a clean carrier gas and analyzed by a chemical ionization mass spectrometer. Gas phase measurements are performed with the same mass spectrometer during the sampling of particles. The characterization shows reproducible results, with a particle size resolution of 1.19 and the transmission efficiency for 15 nm particles being slightly above 50 %. The signal from the evaporation of a test substance can be detected starting from 0.01 ng and shows a linear response in the mass spectrometer. Instrument operation in the range of pg/m3 is demonstrated by an example measurement of 15 nm particles produced by nucleation from dimethylamine, sulfuric acid and water.
Atmospheric nanoaerosols have extensive effects on the Earth’s climate and human health. This cumulative work focuses on the development and characterization of instrumentation for measuring various parameters of atmospheric nanoaerosols, and its use to understand new particle formation from organic precursors. The principal research question is, how the chemical composition of nanoaerosol particles can be measured and how atmospheric chemistry influences aerosol processes, especially new particle formation and growth. Therefore, nanoaerosols are investigated under various aspects. More specifically, an instrument is developed to analyze nanoparticles, and field as well as chamber studies are conducted.
The main project is the instrument development of the Thermal Desorption Differential Mobility Analyzer (TD-DMA, project 1, Wagner et al. (2018)). This instrument analyzes the chemical composition of small aerosol particles. By characterization and testing in chamber experiments, it is proven to be suitable for the analysis of freshly nucleated particles.
The second project (Wagner et al. (2017)) applies a broad spectrum of aerosol measurement instruments for the characterization of aerosol particles produced by a skyscraper blasting. A comprehensive picture of the particle population emitted by the demolition is obtained.
Project 3 (K¨urten et al. (2016)) is also an ambient aerosol measurement, focusing of new particle formation in a rural area in central Germany, and the ability of a negative nitrate CI-APi-TOF to detect various substances in atmosphere. Project 4 (Heinritzi et al. (2016)) is a characterization of the negative nitrate CI-APi-TOF used in projects 1, 3, 5, 6, 7 and 8. The following projects focus on understanding new particle formation from atmospherically abundant organic precursors. Key instruments comprise the negative nitrate CI-APiTOF for gas-phase measurements of the nucleating species, and various sizing and counting instruments for quantifying the particle formation and growth. Project 5 (Kirkby et al. (2016)) shows that biogenic organic compounds formed from alpha-pinene can nucleate on their own without the influence of e.g. sulfuric acid. Project 6 (Tr¨ostl et al. (2016)) describe the subsequent growth of these particles. Project 7 (Stolzenburg et al. (2018)) covers the temperature dependence of this growth and in project 8 (Heinritzi et al. (2018)), the suppressing influence of isoprene on the new particle formation is assessed.
We present a study characterizing aerosol particles resulting from a skyscraper blasting. High mass concentrations with a maximum of 844.9 μg m-3 were present for a short time period of approximately 15 minutes. They result in a day mean of 32.6 μg m-3 compared to a 27.6 μg m-3 background not exceeding the 50 μg m-3 EU maximum permissive value. The increase in particle number concentration was less pronounced with a maximum concentration of 6.9 ⋅ 104 cm-3 compared to the local background value of 1.8 ⋅ 104 cm-3. The size-resolved number concentration shows a single mode of ultrafine particles at approximately 93 nm. The spatial distribution of deposited dust was investigated with Bergerhoff glass collection vessels, showing a decrease with distance. In the deposited dust samples the concentrations of twelve metals was determined, non of them exceeded the regional background concentrations significantly. The chemical composition of individual particles emitted by the demolition was studied by Scanning Electron Microscopy. They were mainly concrete and steel particles, with 60% calcium carbonates, 19% calcium sulfates, 19% silicates and 2% steel. In energy-dispersive X-Ray Spectroscopy, no fibers like asbestos were observed. Using a broad spectrum of instruments and methods, we obtain comprehensive characterization of the particles emitted by the demolition.