Refine
Year of publication
- 2000 (2)
Document Type
- Conference Proceeding (2) (remove)
Language
- English (2) (remove)
Has Fulltext
- yes (2)
Is part of the Bibliography
- no (2)
Institute
- Physik (2)
The determination of the beam emittance using conventional destructive methods suffers from two main disadvantages. The interaction between the ion beam and the measurement device produces a high amount of secondary particles. Those particles interact with the beam and can change the transport properties of the accelerator. Particularly in the low energy section of high current accelerators like proposed for IFMIF, heavy ion inertial fusion devices (HIDIF) and spallation sources (ESS, SNS) the power deposited on the emittance measurement device can lead to extensive heat on the detector itself and can destruct or at least dejust the device (slit or grit for example). CCD camera measurements of the incident light emitted from interaction of beam ions with residual gas are commonly used for determination of the beam emittance. Fast data acquisition and high time resolution are additional features of such a method. Therefore a matrix formalism is used to derive the emittance from the measured profile of the beam [1,2] which does not take space charge effects and emittance growth into account. A new method to derive the phase space distribution of the beam from a single CCD camera image using statistical numerical methods will be presented together with measurements. The results will be compared with measurements gained from a conventional Allison type (slit-slit) emittance measurement device.
Low energy beam transport (LEBT) for a future heavy ion driven inertial fusion (HIDIF [1]) facility is a crucial point using a Bi+ beam of 40 mA at 156 keV. High space charge forces (generalised perveance K=3.6*10-3) restrict the use of electrostatic focussing systems. On the other hand magnetic lenses using space charge compensation suffer from the low particle velocity. Additionally the emittance requirements are very high in order to avoid particle losses in the linac and at ring injection [2]. urthermore source noise and rise time of space charge compensation [3] might enhance particle losses and emittance. Gabor lenses [4] using a continuous space charge cloud for focussing could be a serious alternative to conventional LEBT systems. They combine strong cylinder symmetric focussing with partly space charge compensation and low emittance growth due to lower non linear fields. A high tolerance against source noise and current fluctuations and reduced investment costs are other possible advantages. The proof of principle has already been shown [5, 6]. To broaden the experiences an experimental program was started. Therefrom the first experimental results using a double Gabor lens (DGPL, see fig. 1 ) LEBT system for transporting an high perveance Xe+ beam will be presented and the results of numerical simulations will be shown.