Refine
Year of publication
Document Type
- Preprint (691)
- Article (481)
- Conference Proceeding (8)
- Working Paper (8)
- Doctoral Thesis (3)
- Book (1)
- Part of a Book (1)
Has Fulltext
- yes (1193)
Is part of the Bibliography
- no (1193)
Keywords
- Heavy Ion Experiments (21)
- Hadron-Hadron Scattering (13)
- Hadron-Hadron scattering (experiments) (11)
- LHC (9)
- Deutschland (6)
- Heavy-ion collision (6)
- Jets (6)
- Corporate Governance (5)
- Interbankenabkommen (5)
- ALICE experiment (4)
Institute
- Physik (1102)
- Frankfurt Institute for Advanced Studies (FIAS) (1005)
- Informatik (971)
- Medizin (37)
- Geowissenschaften (14)
- Mathematik (13)
- Wirtschaftswissenschaften (8)
- Biochemie und Chemie (3)
- Biodiversität und Klima Forschungszentrum (BiK-F) (3)
- Informatik und Mathematik (3)
- Biochemie, Chemie und Pharmazie (2)
- Biowissenschaften (2)
- ELEMENTS (2)
- Extern (2)
- Hochschulrechenzentrum (2)
- Institut für Ökologie, Evolution und Diversität (2)
- Senckenbergische Naturforschende Gesellschaft (2)
- Georg-Speyer-Haus (1)
- Geowissenschaften / Geographie (1)
- Sonderforschungsbereiche / Forschungskollegs (1)
- Sportwissenschaften (1)
The consequences of the current COVID-19 pandemic for mental health remain unclear, especially regarding the effects on suicidal behaviors. To assess changes in the pattern of suicide attempt (SA) admissions and completed suicides (CS) in association with the COVID-19 pandemic. As part of a longitudinal study, SA admissions and CS are systematically documented and analyzed in all psychiatric hospitals in Frankfurt/Main (765.000 inhabitants). Number, sociodemographic factors, diagnoses and methods of SA and CS were compared between the periods of March–December 2019 and March–December 2020. The number of CS did not change, while the number of SA significantly decreased. Age, sex, occupational status, and psychiatric diagnoses did not change in SA, whereas the percentage of patients living alone while attempting suicide increased. The rate and number of intoxications as a SA method increased and more people attempted suicide in their own home, which was not observed in CS. Such a shift from public places to home is supported by the weekday of SA, as the rate of SA on weekends was significantly lower during the pandemic, likely because of lockdown measures. Only admissions to psychiatric hospitals were recorded, but not to other institutions. As it seems unlikely that the number of SA decreased while the number of CS remained unchanged, it is conceivable that the number of unreported SA cases increased during the pandemic. Our data suggest that a higher number of SA remained unnoticed during the pandemic because of their location and the use of methods associated with lower lethality.
Hintergrund: Dehntrainings sind eine Maßnahme der betrieblichen Gesundheitsförderung (BGF) für Büroangestellte zur Prävention von muskuloskeletalen Erkrankungen (MSE). Sie können zu Beweglichkeitszuwächsen führen und auf psychischer Ebene entspannen. Ziel der Studie war es, ein standardisiertes und individualisiertes Dehntraining am Gerät, das „five-Business“, auf MSE, Lebensqualität und Beweglichkeit zu untersuchen. Dies ist eine Zusammenfassung der international publizierten Ergebnisse.
Methodik: In diese Untersuchung wurden 252 Proband(innen) eingeschlossen, 156 in die Interventionsgruppe (IG), 96 in die Kontrollgruppe (KG). Die IG absolvierte für 12 Wochen 22–24 Trainingseinheiten am „five-Business“, möglichst zweimal wöchentlich. Die Datenerhebung erfolgte mittels sportmotorischer bzw. Range-of-motion(ROM)-Tests, dem Nordic Questionnaire (NQ) und dem SF-36-Fragebogen in Form einer Prä-Post-Untersuchung.
Ergebnisse: Nach der Intervention gaben im NQ signifikant weniger Proband(innen) der IG Beschwerden im oberen Rücken (p < 0,001) im Vergleich zur KG an; keine signifikanten Unterschiede wurden bei Beschwerden im Nacken, Schultern, Hüfte und dem unteren Rücken gefunden. Der mit dem SF-36 erhobene allgemeine Gesundheitszustand und die gesundheitsbezogene Lebensqualität haben sich (nach subjektiven Angaben) signifikant verbessert (Summenscore IG: p = 0,005). In den ROM-Tests waren die Prä-Post-Differenzen bei IG-Proband(innen) in der Sagittalebene (Finger-Boden-Abstand und Retroflexion; p < 0,001) und im modifizierten Schultertest nach Janda auf der linken Seite (p = 0,003) signifikant größer.
Diskussion: Trotz des in Zeitdauer und Häufigkeit relativ geringen Trainingsaufwandes wurden sowohl auf körperlicher als auch auf psychischer Ebene relevante Verbesserungen erzielt, so dass das „five-Business“-Dehntraining als BGF-Maßnahme empfohlen werden kann.
Background: Intestinal perforation or leakage increases morbidity and mortality of surgical and endoscopic interventions. We identified criteria for use of full-covered, extractable self-expanding metal stents (cSEMS) vs. "Over the scope"-clips (OTSC) for leak closure.
Methods: Patients who underwent endoscopic treatment for postoperative leakage, endoscopic perforation, or spontaneous rupture of the upper gastrointestinal tract between 2006 and 2013 were identified at four tertiary endoscopic centers. Technical success, outcome (e.g. duration of hospitalization, in-hospital mortality), and complications were assessed and analyzed with respect to etiology, size and location of leakage.
Results: Of 106 patients (male: 75 (71%), female: 31 (29%); age (mean ± SD): 62.5 ± 1.3 years, 72 (69%) were treated by cSEMS and 34 (31%) by OTSC. For cSEMS vs. OTSC, mean treatment duration was 41.1 vs. 25 days, p<0.001, leakage size 10 (1-50) vs. 5 (1-30) mm (median (range)), and complications were observed in 68% vs. 8.8%, p<0.001, respectively. Clinical success for primary interventional treatment was observed in 29/72 (40%) vs. 24/34 (70%, p = 0.006), and clinical success at the end of follow-up was 46/72 (64%) vs. 29/34 (85%) for patients treated by cSEMS vs. OTSC; p = 0.04.
Conclusion: OTSC is preferred in small-sized lesions and in perforation caused by endoscopic interventions, cSEMS in patients with concomitant local infection or abscess. cSEMS is associated with a higher frequency of complications. Therefore, OTSC might be preferred if technically feasible. Indication criteria for cSEMS vs. OTSC vary and might impede design of randomized studies.
Background: Due to the steadily increasing number of cancer patients worldwide the early diagnosis and treatment of cancer is a major field of research. The diagnosis of cancer is mostly performed by an experienced pathologist via the visual inspection of histo-pathological stained tissue sections. To save valuable time, low quality cryosections are frequently analyzed with diagnostic accuracies that are below those of high quality embedded tissue sections. Thus, alternative means have to be found that enable for fast and accurate diagnosis as the basis of following clinical decision making.
Methods: In this contribution we will show that the combination of the three label-free non-linear imaging modalities CARS (coherent anti-Stokes Raman-scattering), TPEF (two-photon excited autofluorescence) and SHG (second harmonic generation) yields information that can be translated into computational hematoxylin and eosin (HE) images by multivariate statistics. Thereby, a computational HE stain is generated resulting in pseudo-HE overview images that allow for identification of suspicious regions. The latter are analyzed further by Raman-spectroscopy retrieving the tissue’s molecular fingerprint.
Results: The results suggest that the combination of non-linear multimodal imaging and Raman-spectroscopy possesses the potential as a precise and fast tool in routine histopathology.
Conclusions: As the key advantage, both optical methods are non-invasive enabling for further pathological investigations of the same tissue section, e.g. a direct comparison with the current pathological gold-standard.
Calibration of TCCON column-averaged CO₂: the first aircraft campaign over European TCCON sites
(2011)
The Total Carbon Column Observing Network (TCCON) is a ground-based network of Fourier Transform Spectrometer (FTS) sites around the globe, where the column abundances of CO2, CH4, N2O, CO and O2 are measured. CO2 is constrained with a precision better than 0.25% (1-σ). To achieve a similarly high accuracy, calibration to World Meteorological Organization (WMO) standards is required. This paper introduces the first aircraft calibration campaign of five European TCCON sites and a mobile FTS instrument. A series of WMO standards in-situ profiles were obtained over European TCCON sites via aircraft and compared with retrievals of CO2 column amounts from the TCCON instruments. The results of the campaign show that the FTS measurements are consistently biased 1.1% ± 0.2% low with respect to WMO standards, in agreement with previous TCCON calibration campaigns. The standard a priori profile for the TCCON FTS retrievals is shown to not add a bias. The same calibration factor is generated using aircraft profiles as a priori and with the TCCON standard a priori. With a calibration to WMO standards, the highly precise TCCON CO2 measurements of total column concentrations provide a suitable database for the calibration and validation of nadir-viewing satellites
Calibration of TCCON column-averaged CO₂: the first aircraft campaign over European TCCON sites
(2011)
The Total Carbon Column Observing Network (TCCON) is a ground-based network of Fourier Transform Spectrometer (FTS) sites around the globe, where the column abundances of CO2, CH4, N2O, CO and O2 are measured. CO2 is constrained with a precision better than 0.25 %. To achieve a similarly high accuracy, calibration to World Meteorological Organization (WMO) standards is required. This paper introduces the first aircraft calibration campaign of five European TCCON sites and a mobile FTS instrument. A series of WMO standards in-situ profiles were obtained over European TCCON sites via aircraft and compared with retrievals of CO2 column amounts from the TCCON instruments. The results of the campaign show that the FTS measurements are consistently biased 1.0 % ± 0.2 % low with respect to WMO standards, in agreement with previous TCCON calibration campaigns. The standard a priori profile for the TCCON FTS retrievals is shown to not add a bias. The same calibration factor is generated using aircraft profiles as a priori and with the TCCON standard a priori. With a calibration to WMO standards, the highly precise TCCON CO2 measurements of total column concentrations provide a suitable database for the calibration and validation of nadir-viewing satellites.
New neutron cross section measurements of minor actinides have been performed recently in order to reduce the uncertainties in the evaluated data, which is important for the design of advanced nuclear reactors and, in particular, for determining their performance in the transmutation of nuclear waste. We have measured the 241Am(n,γ) cross section at the n_TOF facility between 0.2 eV and 10 keV with a BaF2 Total Absorption Calorimeter, and the analysis of the measurement has been recently concluded. Our results are in reasonable agreement below 20 eV with the ones published by C. Lampoudis et al. in 2013, who reported a 22% larger capture cross section up to 110 eV compared to experimental and evaluated data published before. Our results also indicate that the 241Am(n,γ) cross section is underestimated in the present evaluated libraries between 20 eV and 2 keV by 25%, on average, and up to 35% for certain evaluations and energy ranges.
The design and operation of innovative nuclear systems requires a better knowledge of the capture and fission cross sections of the Pu isotopes. For the case of capture on 242Pu, a reduction of the uncertainty in the fast region down to 8-12% is required. Moreover, aiming at improving the evaluation of the fast energy range in terms of average parameters, the OECD NEA High Priority Request List (HPRL) requests high-resolution capture measurements with improved accuracy below 2 keV. The current uncertainties also affect the thermal point, where previous experiments deviate from each other by 20%. A fruitful collaboration betwen JGU Mainz and HZ Dresden-Rossendorf within the EC CHANDA project resulted in a 242Pu sample consisting of a stack of seven fission-like targets making a total of 95(4) mg of 242Pu electrodeposited on thin (11.5 μm) aluminum backings. This contribution presents the results of a set of measurements of the 242Pu(n, γ) cross section from thermal to 500 keV combining different neutron beams and techniques. The thermal point was determined at the Budapest Research Reactor by means of Neutron Activation Analysis and Prompt Gamma Analysis, and the resolved (1 eV - 4 keV) and unresolved (1 - 500 keV) resonance regions were measured using a set of four Total Energy detectors at the CERN n_TOF-EAR1.
The accuracy on neutron capture cross section of fissile isotopes must be improved for the design of future nuclear systems such as Gen-IV reactors and Accelerator Driven Systems. The High Priority Request List of the Nuclear Energy Agency, which lists the most important nuclear data requirements, includes also the neutron capture cross sections of fissile isotopes such as 233,235U and 239,241Pu. A specific experimental setup has been used at the CERN n_TOF facility for the measurement of the neutron capture cross section of 235U by a set of micromegas fission detectors placed inside a segmented BaF2 Total Absorption Calorimeter.
The experimental area 2 (EAR-2) at CERNs neutron time-of-flight facility (n_TOF), which is operational since 2014, is designed and built as a short-distance complement to the experimental area 1 (EAR-1). The Parallel Plate Avalanche Counter (PPAC) monitor experiment was performed to characterize the beam pro↓le and the shape of the neutron 'ux at EAR-2. The prompt γ-flash which is used for calibrating the time-of-flight at EAR-1 is not seen by PPAC at EAR-2, shedding light on the physical origin of this γ-flash.
Selection and prioritization of patients with HCC for LT are based on pretransplant imaging diagnostic, taking the risk of incorrect diagnosis. According to the German waitlist guidelines, imaging has to be reported to the allocation organization (Eurotransplant) and pathology reports have to be submitted thereafter. In order to assess current procedures we performed a retrospective multicenter analysis in all German transplant centers with focus on accuracy of imaging diagnostic and tumor classification. 1168 primary LT for HCC were conducted between 2007 and 2013 in Germany. Patients inside the Milan, UCSF, and up-to-seven criteria were misclassified with definitive histologic results in 18%, 15%, and 11%, respectively. Patients pretransplant outside the Milan, UCSF, and up-to-seven criteria were otherwise misclassified in 34%, 43%, and 41%. Recurrence-free survival correlated with classification by posttransplant histological report, but not pretransplant imaging diagnostic. Univariate analysis revealed tumor size, vascular invasion, and grading as significant parameters for outcome, while tumor grading was the only parameter persisting by multivariate testing. Conclusion. There was a relevant percentage (15-40%) of patients misclassified by imaging diagnosis at a time prior to LI-RADS and guidelines to improve imaging of HCC. Outcome analysis showed a good correlation to histological, in contrast poor correlation to imaging diagnosis, suggesting an adjustment of the LT selection and prioritization criteria.
he study of the resonant structures in neutron-nucleus cross-sections, and therefore of the compound-nucleus reaction mechanism, requires spectroscopic measurements to determine with high accuracy the energy of the neutron interacting with the material under study.
To this purpose, the neutron time-of-flight facility n_TOF has been operating since 2001 at CERN. Its characteristics, such as the high intensity instantaneous neutron flux, the wide energy range from thermal to few GeV, and the very good energy resolution, are perfectly suited to perform high-quality measurements of neutron-induced reaction cross sections. The precise and accurate knowledge of these cross sections plays a fundamental role in nuclear technologies, nuclear astrophysics and nuclear physics.
Two different measuring stations are available at the n_TOF facility, called EAR1 and EAR2, with different characteristics of intensity of the neutron flux and energy resolution. These experimental areas, combined with advanced detection systems lead to a great flexibility in performing challenging measurement of high precision and accuracy, and allow the investigation isotopes with very low cross sections, or available only in small quantities, or with very high specific activity.
The characteristics and performances of the two experimental areas of the n_TOF facility will be presented, together with the most important measurements performed to date and their physics case. In addition, the significant upcoming measurements will be introduced.
The aim of this work is to provide a precise and accurate measurement of the 238U(n,γ) reaction cross section in the energy region from 1 eV to 700 keV. This reaction is of fundamental importance for the design calculations of nuclear reactors, governing the behavior of the reactor core. In particular, fast reactors, which are experiencing a growing interest for their ability to burn radioactive waste, operate in the high energy region of the neutron spectrum. In this energy region most recent evaluations disagree due to inconsistencies in the existing measurements of up to 15%. In addition, the assessment of nuclear data uncertainty performed for innovative reactor systems shows that the uncertainty in the radiative capture cross section of 238U should be further reduced to 1–3% in the energy region from 20 eV to 25 keV. To this purpose, addressed by the Nuclear Energy Agency as a priority nuclear data need, complementary experiments, one at the GELINA and two at the n_TOF facility, were proposed and carried out within the 7th Framework Project ANDES of the European Commission. The results of one of these 238U(n,γ) measurements performed at the n_TOF CERN facility are presented in this work. The γ-ray cascade following the radiative neutron capture has been detected exploiting a setup of two C6D6 liquid scintillators. Resonance parameters obtained from this work are on average in excellent agreement with the ones reported in evaluated libraries. In the unresolved resonance region, this work yields a cross section in agreement with evaluated libraries up to 80 keV, while for higher energies our results are significantly higher.
Investigators in the cognitive neurosciences have turned to Big Data to address persistent replication and reliability issues by increasing sample sizes, statistical power, and representativeness of data. While there is tremendous potential to advance science through open data sharing, these efforts unveil a host of new questions about how to integrate data arising from distinct sources and instruments. We focus on the most frequently assessed area of cognition - memory testing - and demonstrate a process for reliable data harmonization across three common measures. We aggregated raw data from 53 studies from around the world which measured at least one of three distinct verbal learning tasks, totaling N = 10,505 healthy and brain-injured individuals. A mega analysis was conducted using empirical bayes harmonization to isolate and remove site effects, followed by linear models which adjusted for common covariates. After corrections, a continuous item response theory (IRT) model estimated each individual subject’s latent verbal learning ability while accounting for item difficulties. Harmonization significantly reduced inter-site variance by 37% while preserving covariate effects. The effects of age, sex, and education on scores were found to be highly consistent across memory tests. IRT methods for equating scores across AVLTs agreed with held-out data of dually-administered tests, and these tools are made available for free online. This work demonstrates that large-scale data sharing and harmonization initiatives can offer opportunities to address reproducibility and integration challenges across the behavioral sciences.
The study of neutron-induced reactions is of high relevance in a wide variety of fields, ranging from stellar nucleosynthesis and fundamental nuclear physics to applications of nuclear technology. In nuclear energy, high accuracy neutron data are needed for the development of Generation IV fast reactors and accelerator driven systems, these last aimed specifically at nuclear waste incineration, as well as for research on innovative fuel cycles. In this context, a high luminosity Neutron Time Of Flight facility, n_TOF, is operating at CERN since more than a decade, with the aim of providing new, high accuracy and high resolution neutron cross-sections. Thanks to the features of the neutron beam, a rich experimental program relevant to nuclear technology has been carried out so far. The program will be further expanded in the near future, thanks in particular to a new high-flux experimental area, now under construction.
The accurate knowledge of the neutron-induced fission cross-sections of actinides and other isotopes involved in the nuclear fuel cycle is essential for the design of advanced nuclear systems, such as Generation-IV nuclear reactors. Such experimental data can also provide the necessary feedback for the adjustment of nuclear model parameters used in the evaluation process, resulting in the further development of nuclear fission models. In the present work, the 240Pu(n,f) cross-section was measured at CERN's n_TOF facility relative to the well-known 235U(n,f) cross section, over a wide range of neutron energies, from meV to almost MeV, using the time-of-flight technique and a set-up based on Micromegas detectors. This measurement was the first experiment to be performed at n_TOF's new experimental area (EAR-2), which offers a significantly higher neutron flux compared to the already existing experimental area (EAR-1). Preliminary results as well as the experimental procedure, including a description of the facility and the data handling and analysis, are presented.
The gradual heterogeneity of climatic factors pose varying selection pressures across geographic distances that leave signatures of clinal variation in the genome. Separating signatures of clinal adaptation from signatures of other evolutionary forces, such as demographic processes, genetic drift, and adaptation to non-clinal conditions of the immediate local environment is a major challenge. Here, we examine climate adaptation in five natural populations of the harlequin fly Chironomus riparius sampled along a climatic gradient across Europe. Our study integrates experimental data, individual genome resequencing, Pool-Seq data, and population genetic modelling. Common-garden experiments revealed a positive correlation of population growth rates corresponding to the population origin along the climate gradient, suggesting thermal adaptation on the phenotypic level. Based on a population genomic analysis, we derived empirical estimates of historical demography and migration. We used an FST outlier approach to infer positive selection across the climate gradient, in combination with an environmental association analysis. In total we identified 162 candidate genes as genomic basis of climate adaptation. Enriched functions among these candidate genes involved the apoptotic process and molecular response to heat, as well as functions identified in other studies of climate adaptation in other insects. Our results show that local climate conditions impose strong selection pressures and lead to genomic adaptation despite strong gene flow. Moreover, these results imply that selection to different climatic conditions seems to converge on a functional level, at least between different insect species.
The Cosmological Lithium Problem refers to the large discrepancy between the abundance of primordial 7Li predicted by the standard theory of Big Bang Nucleosynthesis and the value inferred from the so-called “Spite plateau” in halo stars. A possible explanation for this longstanding puzzle in Nuclear Astrophysics is related to the incorrect estimation of the destruction rate of 7Be, which is responsible for the production of 95% of primordial Lithium. While charged-particle induced reactions have mostly been ruled out, data on the 7Be(n,α) and 7Be(n,p) reactions are scarce or completely missing, so that a large uncertainty still affects the abundance of 7Li predicted by the standard theory of Big Bang Nucleosynthesis. Both reactions have been measured at the n_TOF facility at CERN, providing for the first time data in a wide neutron energy range.