Refine
Year of publication
Document Type
- Preprint (559)
- Article (383)
- Working Paper (2)
Has Fulltext
- yes (944)
Is part of the Bibliography
- no (944)
Keywords
- Heavy Ion Experiments (21)
- Hadron-Hadron scattering (experiments) (11)
- Hadron-Hadron Scattering (10)
- Heavy-ion collision (5)
- Jets (5)
- Atmospheric chemistry (4)
- Collective Flow (4)
- Quark-Gluon Plasma (4)
- Burden of illness (3)
- Healthcare costs (3)
Institute
- Physik (860)
- Frankfurt Institute for Advanced Studies (FIAS) (790)
- Informatik (757)
- Geowissenschaften (33)
- Medizin (33)
- ELEMENTS (6)
- Geowissenschaften / Geographie (5)
- Informatik und Mathematik (4)
- Biowissenschaften (2)
- Buchmann Institut für Molekulare Lebenswissenschaften (BMLS) (2)
Comprehensive analysis of tumour sub-volumes for radiomic risk modelling in locally advanced HNSCC
(2020)
Simple Summary: Radiomic risk models are usually based on imaging features, which are extracted from the entire gross tumour volume (GTV entire ). This approach does not explicitly consider the complex biological structure of the tumours. Therefore, in this retrospective study, we investigated the prognostic value of radiomic analyses based on different tumour sub-volumes using computed tomography imaging of patients with locally advanced head and neck squamous cell carcinoma who were treated with primary radio-chemotherapy. The GTV entire was cropped by different margins to define the rim and corresponding core sub-volumes of the tumour. Furthermore, the best performing tumour rim sub-volume was extended into surrounding tissue with different margins. As a result, the models based on the 5 mm tumour rim and on the 3 mm extended rim sub-volume showed an improved performance compared to models based on the corresponding tumour core. This indicates that the consideration of tumour sub-volumes may help to improve radiomic risk models.
Abstract: Imaging features for radiomic analyses are commonly calculated from the entire gross tumour volume (GTVentire). However, tumours are biologically complex and the consideration of different tumour regions in radiomic models may lead to an improved outcome prediction. Therefore, we investigated the prognostic value of radiomic analyses based on different tumour sub-volumes using computed tomography imaging of patients with locally advanced head and neck squamous cell carcinoma. The GTVentire was cropped by different margins to define the rim and the corresponding core sub-volumes of the tumour. Subsequently, the best performing tumour rim sub-volume was extended into surrounding tissue with different margins. Radiomic risk models were developed and validated using a retrospective cohort consisting of 291 patients in one of the six Partner Sites of the German Cancer Consortium Radiation Oncology Group treated between 2005 and 2013. The validation concordance index (C-index) averaged over all applied learning algorithms and feature selection methods using the GTVentire achieved a moderate prognostic performance for loco-regional tumour control (C-index: 0.61 ± 0.04 (mean ± std)). The models based on the 5 mm tumour rim and on the 3 mm extended rim sub-volume showed higher median performances (C-index: 0.65 ± 0.02 and 0.64 ± 0.05, respectively), while models based on the corresponding tumour core volumes performed less (C-index: 0.59 ± 0.01). The difference in C-index between the 5 mm tumour rim and the corresponding core volume showed a statistical trend (p = 0.10). After additional prospective validation, the consideration of tumour sub-volumes may be a promising way to improve prognostic radiomic risk models.
Purpose: To develop and validate a CT-based radiomics signature for the prognosis of loco-regional tumour control (LRC) in patients with locally advanced head and neck squamous cell carcinoma (HNSCC) treated by primary radiochemotherapy (RCTx) based on retrospective data from 6 partner sites of the German Cancer Consortium - Radiation Oncology Group (DKTK-ROG).
Material and methods: Pre-treatment CT images of 318 patients with locally advanced HNSCC were collected. Four-hundred forty-six features were extracted from each primary tumour volume and then filtered through stability analysis and clustering. First, a baseline signature was developed from demographic and tumour-associated clinical parameters. This signature was then supplemented by CT imaging features. A final signature was derived using repeated 3-fold cross-validation on the discovery cohort. Performance in external validation was assessed by the concordance index (C-Index). Furthermore, calibration and patient stratification in groups with low and high risk for loco-regional recurrence were analysed.
Results: For the clinical baseline signature, only the primary tumour volume was selected. The final signature combined the tumour volume with two independent radiomics features. It achieved moderately good discriminatory performance (C-Index [95% confidence interval]: 0.66 [0.55–0.75]) on the validation cohort along with significant patient stratification (p = 0.005) and good calibration.
Conclusion: We identified and validated a clinical-radiomics signature for LRC of locally advanced HNSCC using a multi-centric retrospective dataset. Prospective validation will be performed on the primary cohort of the HNprädBio trial of the DKTK-ROG once follow-up is completed.
The last decade has seen a sharp increase in the number of scientific publications describing physiological and pathological functions of extracellular vesicles (EVs), a collective term covering various subtypes of cell-released, membranous structures, called exosomes, microvesicles, microparticles, ectosomes, oncosomes, apoptotic bodies, and many other names. However, specific issues arise when working with these entities, whose size and amount often make them difficult to obtain as relatively pure preparations, and to characterize properly. The International Society for Extracellular Vesicles (ISEV) proposed Minimal Information for Studies of Extracellular Vesicles (“MISEV”) guidelines for the field in 2014. We now update these “MISEV2014” guidelines based on evolution of the collective knowledge in the last four years. An important point to consider is that ascribing a specific function to EVs in general, or to subtypes of EVs, requires reporting of specific information beyond mere description of function in a crude, potentially contaminated, and heterogeneous preparation. For example, claims that exosomes are endowed with exquisite and specific activities remain difficult to support experimentally, given our still limited knowledge of their specific molecular machineries of biogenesis and release, as compared with other biophysically similar EVs. The MISEV2018 guidelines include tables and outlines of suggested protocols and steps to follow to document specific EV-associated functional activities. Finally, a checklist is provided with summaries of key points.
We measured the Coulomb dissociation of 16O into 4He and 12C at the R3B setup in a first campaign within FAIR Phase 0 at GSI Helmholtzzentrum für Schwerionenforschung, Darmstadt. The goal was to improve the accuracy of the experimental data for the 12C(α,γ)16O fusion reaction and to reach lower center-ofmass energies than measured so far.
The experiment required beam intensities of 109 16O ions per second at an energy of 500 MeV/nucleon. The rare case of Coulomb breakup into 12C and 4He posed another challenge: The magnetic rigidities of the particles are so close because of the same mass-to-charge-number ratio A/Z = 2 for 16O, 12C and 4He. Hence, radical changes of the R3B setup were necessary. All detectors had slits to allow the passage of the unreacted 16O ions, while 4He and 12C would hit the detectors' active areas depending on the scattering angle and their relative energies. We developed and built detectors based on organic scintillators to track and identify the reaction products with sufficient precision.