Introduction: Reliable and cost-effective diagnostics for hepatitis E virus (HEV) infection are necessary. The aim of our study was to investigate which diagnostic test is most accurate to detect HEV infection in immunocompetent and immunosuppressed patients in a real world setting. Patients and Methods: We performed a retrospective analysis of 1165 patients tested for HEV antibodies and HEV PCR at the same time point. Clinical, laboratory and virological data were taken from patient charts. HEV IgA was measured in a subgroup of 185 patients. Results: HEV RNA was detectable in 61 patients (5.2%); most of them (n = 49, 80.3%/n = 43, 70.5%) were HEV IgM+ and IgG+; however, 12 patients (19.6%) were HEV RNA positive/HEV IgM negative and 17 patients (27.8%) were HEV RNA positive/HEV IgG negative. Ten HEV RNA positive patients (16.4%) had neither HEV IgG nor IgM antibodies. Importantly, all of them were immunosuppressed. HEV IgA testing was less sensitive than HEV IgM for HEV diagnosis. Conclusions: HEV infection can be overlooked in patients without HEV specific antibodies. Performing PCR is necessary to diagnose or exclude HEV infection in immunocompromised hosts. In immunocompetent patients, a screening based on HEV antibodies (IgG/IgM) is sufficient.
Human cytomegalovirus (CMV) is a significant cause of morbidity and mortality in patient groups at risk. We have previously shown that the anti-CMV IgG seroprevalence in an urban region of Germany has changed over the last decades. Overall, a decline from 63.7 to 57.25% had been observed between 1988–1997 and 1998–2008 (p < 0,001). Here, we continuously follow the trends to the most recent decade 2009 to 2018. In a retrospective analysis, we determined the seroprevalence of CMV IgG antibodies in our patient cohort, stratified by gender and selected groups at risk (e.g., patients with HIV infection; women of childbearing age). The overall prevalence of anti-CMV IgG non-significantly declined further from 57.25% in 1998–2008 to 56.48% in 2009–2018 (p = 0.881). Looking at gender differences, overall CMV seroprevalence in males declined to 52.82% (from 55.54% in 1998–2008; p = 0.0254), while it non-significantly increased in females to 59.80%. The high seroprevalence in patients with a known HIV infection further increased from 87.46% in 1998–2008 to 92.93% in the current period (p = 0.9999). In women of childbearing age, no significant changes over the last three decades could be observed. The CMV seroprevalence in oncological patients was determined to be 60.64%. Overall, the former significant decline of CMV seroprevalence between the decades 1988–1997 and 1998–2008 in this urban region of Germany slowed down to a non-significant decrease of 0.77% (1998–2008 vs. 2009–2018). This might be an indicator that CMV seroprevalence has reached a plateau.
The novel coronavirus SARS-CoV-2 is the causative agent of the acute respiratory disease COVID-19, which has become a global concern due to its rapid spread. Meanwhile, increased demand for testing has led to a shortage of reagents and supplies and compromised the performance of diagnostic laboratories in many countries. Both the World Health Organization (WHO) and the Center for Disease Control and Prevention (CDC) recommend multi-step RT-PCR assays using multiple primer and probe pairs, which might complicate the interpretation of the test results, especially for borderline cases. In this study, we describe an alternative RT-PCR approach for the detection of SARS-CoV-2 RNA that can be used for the probe-based detection of clinical isolates in diagnostics as well as in research labs using a low-cost SYBR green method. For the evaluation, we used samples from patients with confirmed SARS-CoV-2 infections and performed RT-PCR assays along with successive dilutions of RNA standards to determine the limit of detection. We identified an M-gene binding primer and probe pair highly suitable for the quantitative detection of SARS-CoV-2 RNA for diagnostic and research purposes.
Multicentre comparison of quantitative PCR-based assays to detect SARS-CoV-2, Germany, March 2020
(2020)
Containment strategies and clinical management of coronavirus disease (COVID-19) patients during the current pandemic depend on reliable diagnostic PCR assays for the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Here, we compare 11 different RT-PCR test systems used in seven diagnostic laboratories in Germany in March 2020. While most assays performed well, we identified detection problems in a commonly used assay that may have resulted in false-negative test results during the first weeks of the pandemic.
Background: In the pandemic, testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) by real-time polymerase chain reaction is one of the pillars on which countermeasures are based. Factors limiting the output of laboratories interfere with the effectiveness of public health measures. Conserving reagents by pooling samples in low-probability settings is proposed but may cause dilution and loss of sensitivity. Blood transfusion services had experience in performance of high throughput nucleic acid testing (NAT) analysis and can support the national health system by screening of the inhabitants for SARS-COV-2.
Methods: We evaluated a new approach of a multiple-swab method by simultaneously incubating multiple respiratory swabs in a single tube. Analytical sensitivity was constant up to a total number of 50 swabs. It was consequently applied in the testing of 50 symptomatic patients (5-sample pools) as well as 100 asymptomatic residents of a nursing home (10-sample pools).
Results: The novel method did not cause false-negative results with nonsignificantly differing cycle threshold values between single-swab and multiple-swab NAT. In two routine applications, all minipools containing positive patient samples were correctly identified.
Conclusions: The new method enables countries to increase the total number of testing significantly. The multiple-swab method is able to screen system relevant groups of employees frequently. The example in Germany shows that blood transfusion services can support general health systems with their experience in NAT and their high-throughput instruments. Screening of a huge number of inhabitants is currently the only option to prevent a second infection wave and enable exit strategies in many countries.
In resource-limited or point-of-care settings, rapid diagnostic tests (RDTs), that aim to simultaneously detect HIV antibodies and p24 capsid (p24CA) antigen with high sensitivity, can pose important alternatives to screen for early infections. We evaluated the performance of the antibody and antigen components of the old and novel version of the Determine™ HIV-1/2 Ag/Ab Combo RDTs in parallel to quantifications in a fourth-generation antigen/antibody immunoassay (4G-EIA), p24CA antigen immunoassay (p24CA-EIA), immunoblots, and nucleic acid quantification. We included plasma samples of acute, treatment-naïve HIV-1 infections (Fiebig stages I–VI, subtypes A1, B, C, F, CRF02_AG, CRF02_AE, URF) or chronic HIV-1 and HIV-2 infections. The tests’ antigen component was evaluated also for a panel of subtype B HIV-1 transmitted/founder (T/F) viruses, HIV-2 strains and HIV-2 primary isolates. Furthermore, we assessed the analytical sensitivity of the RDTs to detect p24CA using a highly purified HIV-1NL4-3 p24CA standard. We found that 77% of plasma samples from acutely infected, immunoblot-negative HIV-1 patients in Fiebig stages II–III were identified by the new RDT, while only 25% scored positive in the old RDT. Both RDTs reacted to all samples from chronically HIV-1-infected and acutely HIV-1-infected patients with positive immunoblots. All specimens from chronically infected HIV-2 patients scored positive in the new RDT. Of note, the sensitivity of the RDTs to detect recombinant p24CA from a subtype B virus ranged between 50 and 200 pg/mL, mirrored also by the detection of HIV-1 T/F viruses only at antigen concentrations tenfold higher than suggested by the manufacturer. The RTD failed to recognize any of the HIV-2 viruses tested. Our results indicate that the new version of the Determine™ HIV-1/2 Ag/Ab Combo displays an increased sensitivity to detect HIV-1 p24CA-positive, immunoblot-negative plasma samples compared to the precursor version. The sensitivity of 4G-EIA and p24CA-EIA to detect the major structural HIV antigen, and thus to diagnose acute infections prior to seroconversion, is still superior.