his study aims at a detailed characterization of an ultra-fine aerosol particle counting system for operation on board the Russian high altitude research aircraft M-55 "Geophysica" (maximum ceiling of 21 km). The COndensation PArticle counting Systems (COPAS) consists of an aerosol inlet and two dual-channel continuous flow Condensation Particle Counters (CPCs).
The aerosol inlet, adapted for COPAS measurements on board the M-55 "Geophysica", is described concerning aspiration, transmission, and transport losses. The counting efficiencies of the CPCs using the chlorofluorocarbon FC-43 as the working fluid are studied experimentally at two pressure conditions, 300 hPa and 70 hPa. Three COPAS channels are operated with different temperature differences between the saturator and the condenser block yielding smallest detectable particle sizes (dp50 – as 50% detection "cut off" diameters) of 6 nm, 11 nm, and 15 nm, respectively, at ambient pressure of 70 hPa. The fourth COPAS channel is operated with an aerosol heating line (250°C) for a determination of the non-volatile number of particles. The heating line is experimentally proven to volatilize pure H2SO4-H2O particles for a particle diameter (dp) range of 11 nm<dp<200 nm.
Additionally this study includes investigation to exclude auto-nucleation of the working fluid inside the CPCs. An instrumental inter-comparison (cross-correlation) has been performed for several measurement flights and mission flights in the Arctic and the Tropics are discussed. Finally, COPAS measurements are used for an aircraft plume crossing analysis.
This study presents an evaluation of a pulse height condensation particle counter (PH-CPC) and an expansion condensation particle counter (E-CPC) in terms of measuring ambient and laboratory-generated molecular and ion clusters. Ambient molecular cluster concentrations were measured with both instruments as they were deployed in conjunction with an ion spectrometer and other aerosol instruments in Hyytiälä, Finland at the SMEAR II station between 1 March and 30 June 2007. The observed cluster concentrations varied and ranged from some thousands to 100 000 cm -3. Both instruments showed similar (within a factor of ~5) concentrations. An average size of the detected clusters was approximately 1.8 nm. As the atmospheric measurement of sub 2-nm particles and molecular clusters is a challenging task, we conclude that most likely we were unable to detect the smallest clusters. Nevertheless, the reported concentrations are the best estimates to date for minimum cluster concentrations in a boreal forest environment.
The ambient and laboratory molecular and ion clusters were investigated. Here we present data on the ambient concentrations of both charged and uncharged molecular clusters as well as the performance of a pulse height condensation particle counter (PH-CPC) and an expansion condensation particle counter (E-CPC). The ambient molecular cluster concentrations were measured using both instruments, and they were deployed in conjunction with ion spectrometers and other aerosol instruments in Hyytiälä, Finland at the SMEAR II station during 1 March to 30 June 2007. The observed cluster concentrations varied and were from ca. 1000 to 100 000 cm−3. Both instruments showed similar concentrations. The average size of detected clusters was approximately 1.8 nm. As the atmospheric measurements at sub 2-nm particles and molecular clusters are a challenging task, and we were most likely unable to detect the smallest clusters, the reported concentrations are our best estimates for minimum cluster concentrations in boreal forest environment.