In evidence-based weight-loss programs weight regain is common after an initial weight reduction. Eating slowly significantly lowers meal energy intake and hunger ratings. Despite this knowledge, obese individuals do not implement this behaviour. We, thus tested the hypothesis of changing eating behaviour with an intra-oral medical device leading to constant weight reduction in overweight and obesity.
Six obese patients (6 men, age 56 ± 14, BMI 29 ± 2 kg / m2) with increased CVRF profile were included in this prospective study. All patients had been treated for obesity during the last 10 years in a single centre and had at least 3 frustrate evidence-based diets. Patients received a novel non-invasive intra-oral medical device to slow eating time. Further advice included not to count calories, to avoid any other form of diet, to take their time with their meals, and to eat whatever they liked.
This device was used only during meals for the first 4 to 8 weeks for a total of 88 [20–160] hours. Follow-up period was 23 [15–38] months. During this period, patients lost 11% [5–20%] (p<0.001) of their initial weight. At 12 months, all patients had lost >5%, and 67% (4/6) achieved a >10% bodyweight loss. In the course of the study, altered eating patterns were observed. There were no complications with the medical device. Of note, all patients continued to lose weight after the initial intervention period (p<0.001) and none of them had weight regain.
With this medical device, overweight and obese patients with a history of previously frustrating attempts to lose weight achieved a significant and sustained weight loss over two years. These results warrant the ongoing prospective randomised controlled trial to prove concept and mechanism of action.
Background: Circulating progenitor cells (CPC) contribute to the homeostasis of the vessel wall, and a reduced CPC count predicts cardiovascular morbidity and mortality. We tested the hypothesis that CPC count improves cardiovascular risk stratification and that this is modulated by low-grade inflammation. Methodology/Principal Findings: We pooled data from 4 longitudinal studies, including a total of 1,057 patients having CPC determined and major adverse cardiovascular events (MACE) collected. We recorded cardiovascular risk factors and high-sensitive C-reactive protein (hsCRP) level. Risk estimates were derived from Cox proportional hazard analyses. CPC count and/or hsCRP level were added to a reference model including age, sex, cardiovascular risk factors, prevalent CVD, chronic renal failure (CRF) and medications. The sample was composed of high-risk individuals, as 76.3% had prevalent CVD and 31.6% had CRF. There were 331 (31.3%) incident MACE during an average 1.7±1.1 year follow-up time. CPC count was independently associated with incident MACE even after correction for hsCRP. According to C-statistics, models including CPC yielded a non-significant improvement in accuracy of MACE prediction. However, the integrated discrimination improvement index (IDI) showed better performance of models including CPC compared to the reference model and models including hsCRP in identifying MACE. CPC count also yielded significant net reclassification improvements (NRI) for CV death, non-fatal AMI and other CV events. The effect of CPC was independent of hsCRP, but there was a significant more-than-additive interaction between low CPC count and raised hsCRP level in predicting incident MACE. Conclusions/Significance: In high risk individuals, a reduced CPC count helps identifying more patients at higher risk of MACE over the short term, especially in combination with a raised hsCRP level.
Quantification of circulating endothelial progenitor cells using the modified ISHAGE protocol
(2010)
Aims: Circulating endothelial progenitor cells (EPC), involved in endothelial regeneration, neovascularisation, and determination of prognosis in cardiovascular disease can be characterised with functional assays or using immunofluorescence and flow cytometry. Combinations of markers, including CD34+KDR+ or CD133+KDR+, are used. This approach, however may not consider all characteristics of EPC. The lack of a standardised protocol with regards to reagents and gating strategies may account for the widespread inter-laboratory variations in quantification of EPC. We, therefore developed a novel protocol adapted from the standardised so-called ISHAGE protocol for enumeration of haematopoietic stem cells to enable comparison of clinical and laboratory data. Methods and Results: In 25 control subjects, 65 patients with coronary artery disease (CAD; 40 stable CAD, 25 acute coronary syndrome/acute myocardial infarction (ACS)), EPC were quantified using the following approach: Whole blood was incubated with CD45, KDR, and CD34. The ISHAGE sequential strategy was used, and finally, CD45dimCD34+ cells were quantified for KDR. A minimum of 100 CD34+ events were collected. For comparison, CD45+CD34+ and CD45-CD34+ were analysed simultaneously. The number of CD45dimCD34+KDR+ cells only were significantly higher in healthy controls compared to patients with CAD or ACS (p = 0.005 each, p<0.001 for trend). An inverse correlation of CD45dimCD34+KDR+ with disease activity (r = -0.475, p<0.001) was confirmed. Only CD45dimCD34+KDR+ correlated inversely with the number of diseased coronaries (r = -0.344; p<0.005). In a second study, a 4-week de-novo treatment of atorvastatin in stable CAD evoked an increase only of CD45dimCD34+KDR+ EPC (p<0.05). CD45+CD34+KDR+ and CD45-CD34+KDR+ were indifferent between the three groups. Conclusion: Our newly established protocol adopted from the standardised ISHAGE protocol achieved higher accuracy in EPC enumeration confirming previous findings with respect to the correlation of EPC with disease activity and the increase of EPC during statin therapy. The data of this study show the CD45dim fraction to harbour EPC.