Refine
Year of publication
Document Type
- Article (30)
- Doctoral Thesis (1)
- Working Paper (1)
Has Fulltext
- yes (32)
Is part of the Bibliography
- no (32)
Keywords
- Musculoskeletal system (4)
- ergonomics (3)
- inertial motion capture (3)
- Healthy adults (2)
- Jaw (2)
- Knees (2)
- Legs (2)
- Myalgia (2)
- Postural control (2)
- kinematic analysis (2)
- musculoskeletal disorders (2)
- ACLF (1)
- AD patients (1)
- Anatomy (1)
- Arms (1)
- Back scan (1)
- Bewegungsanalyse mit Inertialsensoren (1)
- Blocked occlusion (1)
- Body sway (1)
- CRM1 (1)
- Custom-made mouthguard (1)
- DST (1)
- Dentists (1)
- Deutschland (1)
- Drug susceptibility testing (1)
- Ergonomic analysis (1)
- Ergonomics (1)
- Ergonomie am Arbeitsplatz (1)
- Ergonomische Analyse (1)
- Factor analysis (1)
- GTPase (1)
- Glioma (1)
- Hedging (1)
- Hip (1)
- Inertial motion capture (1)
- Investmentfonds (1)
- Investmentsparen (1)
- Isocitrate dehydrogenase (1)
- Jumping (1)
- Kapitalertrag (1)
- Kapitalgewinn (1)
- Limited Partnership (1)
- Long Term Investment (1)
- M. Intracellulare (1)
- M. avium (1)
- M. avium complex (1)
- M. chimaera (1)
- MEIS2 (1)
- MRI patterns of gliomas (1)
- Medical research (1)
- Meersseman test (1)
- Musculoskeletal diseases (1)
- Musculoskeletal mechanics (1)
- Musculoskeletal problems (1)
- Muskuloskelettale Erkrankungen (1)
- Mängelhaftung (1)
- NTM (1)
- Non-tuberculous mycobacteria (1)
- Normal distribution (1)
- Occupational health (1)
- Orthopaedics (1)
- PBX1 (1)
- PWI (1)
- Pension Finance (1)
- Posture analysis (1)
- Preventive medicine (1)
- Private Altersversorgung (1)
- Pseudoprogression (1)
- RULA (1)
- Ready-made mouthguard (1)
- Regulation (1)
- Rentenreform (1)
- Rheb (1)
- Risiko (1)
- SPSS (1)
- Shortfall Risk (1)
- Skeletal joints (1)
- Sphingosine-1-Phosphate (1)
- Sport (1)
- Symmetrical blocked occlusion (1)
- TALE-homdomain protein (1)
- TSC2 (1)
- Taekwondoka (1)
- Torque (1)
- Translational research (1)
- Tubers (1)
- Ubiquitin (1)
- Ubiquitin-Protein-Ligase (1)
- Upper body posture (1)
- Videorasterstereography (1)
- Weight distribution (1)
- Workplace ergonomics (1)
- [18F]FET PET (1)
- acute decompensation (1)
- acute-on-chronic liver failure (1)
- amyloid precursor protein (APP) (1)
- apoptosis (1)
- body sway (1)
- body weight distribution (1)
- cirrhosis (1)
- cleaning (1)
- computed tomography (1)
- controlled nuclear import (1)
- dental assistant (1)
- dental treatment concept (1)
- dentist (1)
- dentist’s chair design (1)
- female subjects (1)
- glioblastoma (1)
- hepatic encephalopathy (1)
- human factors (1)
- inertial motion units (1)
- inertial sensors (1)
- kinematics (1)
- liver (1)
- lymphocytes (1)
- mTOR (1)
- malignant glioma (1)
- movement pattern (1)
- movement profile (1)
- neurogenesis (1)
- portal hypertension (1)
- portosystemic shunt (1)
- posttranslational modification (1)
- presenilin-1 (1)
- regorafenib (1)
- regorafenib csf concentration (1)
- risk assessment (1)
- running (1)
- sonoSens (1)
- spontaneous portosystemic shunt (1)
- standard value (1)
- statistical parametric mapping (1)
- stem cell niche (1)
- subventricular zone (1)
- transgenic mice (1)
- triathlon (1)
- vacuuming (1)
- wearable sensors (1)
- work place evaluation (1)
Institute
Standard values of the upper body posture in healthy adults with special regard to age, sex and BMI
(2023)
In order to classify and analyze the parameters of upper body posture in clinical or physiotherapeutic settings, a baseline in the form of standard values with special regard to age, sex and BMI is required. Thus, subjectively healthy men and women aged 21–60 years were measured in this project. The postural parameters of 800 symptom-free male (n = 397) and female (n = 407) volunteers aged 21–60 years (Ø♀: 39.7 ± 11.6, Ø ♂: 40.7 ± 11.5 y) were studied. The mean height of the men was 1.8 ± 0.07 m, with a mean body weight of 84.8 ± 13.1 kg and an average BMI of 26.0 ± 3.534 kg/m2. In contrast, the mean height of the women was 1.67 ± 0.06 m, with a mean body weight of 66.5 ± 12.7 kg and an average BMI of 23.9 ± 4.6 kg/m2. By means of video rasterstereography, a 3-dimensional scan of the upper back surface was measured when in a habitual standing position. The means or medians, confidence intervals, tolerance ranges, the minimum, 2.5, 25, 50, 75, 97.5 percentiles and the maximum, plus the kurtosis and skewness of the distribution, were calculated for all parameters. Additionally, ANOVA and a factor analyses (sex, BMI, age) were conducted. In both sexes across all age groups, balanced, symmetrical upper body statics were evident. Most strikingly, the females showed greater thoracic kyphosis and lumbar lordosis angles (kyphosis: Ø ♀ 56°, Ø♂ 51°; lordosis: Ø ♀ 49°, Ø♂ 32°) and lumbar bending angles (Ø ♀ 14°, Ø♂ 11°) than the males. The distance between the scapulae was more pronounced in men. These parameters also show an increase with age and BMI, respectively. Pelvic parameters were independent of age and sex. The upper body postures of women and men between the ages of 21 and 60 years were found to be almost symmetrical and axis-conforming with a positive correlation for BMI or age. Consequently, the present body posture parameters allow for comparisons with other studies, as well as for the evaluation of clinical (interim) diagnostics and applications.
Traditional ergonomic risk assessment tools such as the Rapid Upper Limb Assessment (RULA) are often not sensitive enough to evaluate well-optimized work routines. An implementation of kinematic data captured by inertial sensors is applied to compare two work routines in dentistry. The surgical dental treatment was performed in two different conditions, which were recorded by means of inertial sensors (Xsens MVN Link). For this purpose, 15 (12 males/3 females) oral and maxillofacial surgeons took part in the study. Data were post processed with costume written MATLAB® routines, including a full implementation of RULA (slightly adjusted to dentistry). For an in-depth comparison, five newly introduced levels of complexity of the RULA analysis were applied, i.e., from lowest complexity to highest: (1) RULA score, (2) relative RULA score distribution, (3) RULA steps score, (4) relative RULA steps score occurrence, and (5) relative angle distribution. With increasing complexity, the number of variables times (the number of resolvable units per variable) increased. In our example, only significant differences between the treatment concepts were observed at levels that are more complex: the relative RULA step score occurrence and the relative angle distribution (level 4 + 5). With the presented approach, an objective and detailed ergonomic analysis is possible. The data-driven approach adds significant additional context to the RULA score evaluation. The presented method captures data, evaluates the full task cycle, and allows different levels of analysis. These points are a clear benefit to a standard, manual assessment of one main body position during a working task.
Triathletes often experience incoordination at the start of a transition run (TR); this is possibly reflected by altered joint kinematics. In this study, the first 20 steps of a run after a warm-up run (WR) and TR (following a 90 min cycling session) of 16 elite, male, long-distance triathletes (31.3 ± 5.4 years old) were compared. Measurements were executed on the competition course of the Ironman Frankfurt in Germany. Pacing and slipstream were provided by a cyclist in front of the runner. Kinematic data of the trunk and leg joints, step length, and step rate were obtained using the MVN Link inertial motion capture system by Xsens. Statistical parametric mapping was used to compare the active leg (AL) and passive leg (PL) phases of the WR and TR. In the TR, more spinal extension (~0.5–1°; p = 0.001) and rotation (~0.2–0.5°; p = 0.001–0.004), increases in hip flexion (~3°; ~65% AL−~55% PL; p = 0.001–0.004), internal hip rotation (~2.5°; AL + ~0–30% PL; p = 0.001–0.024), more knee adduction (~1°; ~80–95% AL; p = 0.001), and complex altered knee flexion patterns (~2–4°; AL + PL; p = 0.001–0.01) occurred. Complex kinematic differences between a WR and a TR were detected. This contributes to a better understanding of the incoordination in transition running.
Background; Musculoskeletal disorders (MSD) are a common health problem among dentists. Dental treatment is mainly performed in a sitting position. The aim of the study was to quantify the effect of different ergonomic chairs on the sitting position. In addition, it was tested if the sitting position of experienced workers is different from a non-dental group.
Methods; A total of 59 (28 m/31f) subjects, divided into two dentist groups according to their work experience (students and dentists (9 m/11f) < 10 years, dentists (9 m/10f) ≥ 10 years) and a control group (10 m/10f) were measured. A three-dimensional back scanner captured the bare back of all subjects sitting on six dentist’s chairs of different design. Initially, inter-group comparisons per chair, firstly in the habitual and secondly in the working postures, were carried out. Furthermore, inter-chair comparison was conducted for the habitual as well as for the working postures of all subjects and for each group. Finally, a comparison between the habitual sitting posture and the working posture for each respective chair (intra-chair comparison) was conducted (for all subjects and for each group). In addition, a subjective assessment of each chair was made.
For the statistical analysis, non-parametric tests were conducted and the level of significance was set at 5%.
Results: When comparing the three subject groups, all chairs caused a more pronounced spinal kyphosis in experienced dentists. In both conditions (habitual and working postures), a symmetrical sitting position was assumed on each chair.
The inter-chair comparisons showed no differences regarding the ergonomic design of the chairs. The significances found in the inter-chair comparisons were all within the measurementerror and could, therefore, be classified as clinically irrelevant.
The intra-chair comparison (habitual sitting position vs. working sitting position) illustrated position-related changes in the sagittal, but not in the transverse, plane. These changes were only position-related (forward leaned working posture) and were not influenced by the ergonomic sitting design of the respective chair. There are no differences between the groups in the subjective assessment of each chair.
Conclusions; Regardless of the group or the dental experience, the ergonomic design of the dentist’s chair had only a marginal influence on the upper body posture in both the habitual and working sitting postures. Consequently, the focus of the dentist’s chair, in order to minimize MSD, should concentrate on adopting a symmetrical sitting posture rather than on its ergonomic design.
Background & Aims: Spontaneous portosystemic shunts (SPSS) frequently develop in liver cirrhosis. Recent data suggested that the presence of a single large SPSS is associated with complications, especially overt hepatic encephalopathy (oHE). However, the presence of >1 SPSS is common. This study evaluates the impact of total cross-sectional SPSS area (TSA) on outcomes in patients with liver cirrhosis.
Methods: In this retrospective international multicentric study, CT scans of 908 cirrhotic patients with SPSS were evaluated for TSA. Clinical and laboratory data were recorded. Each detected SPSS radius was measured and TSA calculated. One-year survival was the primary endpoint and acute decompensation (oHE, variceal bleeding, ascites) was the secondary endpoint.
Results: A total of 301 patients (169 male) were included in the training cohort. Thirty percent of all patients presented with >1 SPSS. A TSA cut-off of 83 mm2 was used to classify patients with small or large TSA (S-/L-TSA). Patients with L-TSA presented with higher model for end-stage liver disease score (11 vs. 14) and more commonly had a history of oHE (12% vs. 21%, p <0.05). During follow-up, patients with L-TSA experienced more oHE episodes (33% vs. 47%, p <0.05) and had lower 1-year survival than those with S-TSA (84% vs. 69%, p <0.001). Multivariate analysis identified L-TSA (hazard ratio 1.66; 95% CI 1.02–2.70, p <0.05) as an independent predictor of mortality. An independent multicentric validation cohort of 607 patients confirmed that patients with L-TSA had lower 1-year survival (77% vs. 64%, p <0.001) and more oHE development (35% vs. 49%, p <0.001) than those with S-TSA.
Conclusion: This study suggests that TSA >83 mm2 increases the risk for oHE and mortality in patients with cirrhosis. Our results support the clinical use of TSA/SPSS for risk stratification and decision-making in the management of patients with cirrhosis.
Lay summary: The prevalence of spontaneous portosystemic shunts (SPSS) is higher in patients with more advanced chronic liver disease. The presence of more than 1 SPSS is common in advanced chronic liver disease and is associated with the development of hepatic encephalopathy. This study shows that total cross-sectional SPSS area (rather than diameter of the single largest SPSS) predicts survival in patients with advanced chronic liver disease. Our results support the clinical use of total cross-sectional SPSS area for risk stratification and decision-making in the management of SPSS.
Objectives: Symmetrical dental occlusion blocking is used in dentistry as a quick diagnostic tool to test for potential influences of the craniomandibular system on body sway and weight distribution. This study presents the changes of body sway and pressure distribution in healthy subjects, free of a temporomandibular dysfunction (TMD). Immediate effects between occlusal blocking and rest position on body sway and body weight distribution in general, as well as for both genders and for four age decades will be evaluated.
Materials and methods: 725 (396f/329 m) subjects (neither subjective signs of TMD nor acute/chronic complaints in the musculoskeletal system) volunteered (21 to 60 years) while both genders were divided into four age groups according to decades. A pressure measuring platform was used. Body sway and weight distribution were recorded in two dental occlusion conditions (a) in rest position and (b) symmetrical blocking (bicuspid region) by cotton rolls.
Results: Both, the frontal sway and the sagittal sway reduced by 0.67 mm (t(724) = − 3.9 (p < 0.001)) and by 0.33 mm (t(724) = − 3.4 (p < 0.001)). The relative pressure under the left forefoot increased by 0.33% (t(724) = 2.88 (p < 0.001)) and the relative pressure overall under the forefoot increased by 0.67% (t(724) = − 3.4 (p < 0.001)). Gender-specific, age-specific and BMI-specific reactions could not be identified.
Conclusions: Subjects, free of any TMD and with no complaints of the musculoskeletal system, show small changes of the body sway and weight distribution when biting symmetrically on a cotton roll. These changes are independent of age, gender or body mass index (BMI). Due to the relative large sample size, the presented results can also be seen as norm values when body sway is used as an additional assessment of a TMD.
Background: In clinical practice range of motion (RoM) is usually assessed with low-cost devices such as a tape measure (TM) or a digital inclinometer (DI). However, the intra- and inter-rater reliability of typical RoM tests differ, which impairs the evaluation of therapy progress. More objective and reliable kinematic data can be obtained with the inertial motion capture system (IMC) by Xsens. The aim of this study was to obtain the intra- and inter-rater reliability of the TM, DI and IMC methods in five RoM tests: modified Thomas test (DI), shoulder test modified after Janda (DI), retroflexion of the trunk modified after Janda (DI), lateral inclination (TM) and fingertip-to-floor test (TM).
Methods: Two raters executed the RoM tests (TM or DI) in a randomized order on 22 healthy individuals while, simultaneously, the IMC data (Xsens MVN) was collected. After 15 warm-up repetitions, each rater recorded five measurements.
Findings: Intra-rater reliabilities were (almost) perfect for tests in all three devices (ICCs 0.886–0.996). Inter-rater reliability was substantial to (almost) perfect in the DI (ICCs 0.71–0.87) and the IMC methods (ICCs 0.61–0.993) and (almost) perfect in the TM methods (ICCs 0.923–0.961). The measurement error (ME) for the tests measured in degree (°) was 0.9–3.3° for the DI methods and 0.5–1.2° for the IMC approaches. In the tests measured in centimeters the ME was 0.5–1.3cm for the TM methods and 0.6–2.7cm for the IMC methods. Pearson correlations between the results of the DI or the TM respectively with the IMC results were significant in all tests except for the shoulder test on the right body side (r = 0.41–0.81).
Interpretation: Measurement repetitions of either one or multiple trained raters can be considered reliable in all three devices.
In the application of range of motion (ROM) tests there is little agreement on the number of repetitions to be measured and the number of preceding warm-up protocols. In stretch training a plateau in ROM gains can be seen after four to five repetitions. With increasing number of repetitions, the gain in ROM is reduced. This study examines the question of whether such an effect occurs in common ROM tests. Twenty-two healthy sport students (10 m/12 f.) with an average age of 25.3 ± 1.94 years (average height 174.1 ± 9.8 cm; weight 66.6 ± 11.3 kg and BMI 21.9 ± 2.0 kg/cm2) volunteered in this study. Each subject performed five ROM tests in a randomized order—measured either via a tape measure or a digital inclinometer: Tape measure was used to evaluate the Fingertip-to-Floor test (FtF) and the Lateral Inclination test (LI). Retroflexion of the trunk modified after Janda (RF), Thomas test (TT) and a Shoulder test modified after Janda (ST) were evaluated with a digital inclinometer. In order to show general acute effects within 20 repetitions we performed ANOVA/Friedman-test with multiple comparisons. A non-linear regression was then performed to identify a plateau formation. Significance level was set at 5%. In seven out of eight ROM tests (five tests in total with three tests measured both left and right sides) significant flexibility gains were observed (FtF: p < 0.001; LI-left/right: p < 0.001/0.001; RF: p = 0.009; ST-left/right: p < 0.001/p = 0.003; TT-left: p < 0.001). A non-linear regression with random effects was successfully applied on FtF, RF, LI-left/right, ST-left and TT-left and thus, indicate a gradual decline in the amount of gained ROM. An acute effect was observed in most ROM tests, which is characterized by a gradual decline of ROM gain. For those tests, we can state that the acute effect described in the stretching literature also applies to the performance of typical ROM tests. Since a non-linear behavior was shown, it is the decision of the practitioner to weigh up between measurement accuracy and expenditure. Researchers and practitioners should consider this when applying ROM assessments to healthy young adults.
Background: Temporary occlusal changes and their influence on the upper body statics are still controversially discussed. Furthermore, concrete statements on whether age- or gender-specific differences in neurophysiological reactions exist are missing. Therefore, it is the aim of this study to evaluate the immediate effects of a symmetrical occlusion blocking on the upper body posture. These effects shall be investigated for both genders and for a larger age range.
Methods: In this study, 800 (407f/393 m) subjects volunteered aged from 21 to 60 years. Both genders were divided into four age groups according to decades. The three-dimensional upper body posture was measured by using the rasterstereography (ABW-Bodymapper). The habitual static posture was measured in two dental occlusion conditions (a) in rest position and (b) symmetrical blocking in the bicuspid region by cotton rolls.
Results: A significant reduction of the trunk length (0.72 mm; p < 0.001), an increase of the lumbar (0.30°; p < 0.001) and the thoracic bending angle (0.14°; p = 0.001), a reduction of the spinal forward decline (0.16°; p < 0.001) and a reduction of the scapular distance (0.36 mm; p = 0.001) was found. Gender-specific reactions can only be recorded in scapular distance, in that regard men reduce this distance while over all age groups women did not show a significant change.
Discussion: Slight gender- and age-independent reactions due to a symmetric occlusion blockade are shown: A gender independent reaction of the spinal related variables in the sagittal plane (thoracic and lumbar flexion angle, trunk length, spinal forward decline). In addition, a gender specific change of the shoulder blade distance could be observed, where men reduced the distance while female did not show a change. However, since these reactions are of a minimum amount, it can be concluded that neurophysiological compensation mechanisms work equally well regardless of age and sex, and the upper body posture of healthy people changes only very slightly due to a temporarily symmetrical altered bite position.
The aim of this study was to investigate gender-specific influences of different symmetric and asymmetric occlusion conditions on postural control during standing and walking. The study involved 59 healthy adult volunteers (41 f/19 m) aged between 22 and 53 years (30.2 ± 6.3 years). Postural control measurements were carried out using a pressure plate by measuring plantar pressure distribution during standing and walking test conditions. Seven different occlusion conditions were tested. Prior to a MANOVA model analysis, the relationship between the two test conditions were checked using a factor analysis with a varying number of factors (between 2 and 10). The plantar pressure distributions during walking and standing are independent test conditions. The coefficient of variance across all variables between the conditions and genders was not significant: t(46) = 1.51 (p = 0.13). No statement can be made whether, or not, the influence of gender is greater than the influence of the conditions. Healthy male and female test subjects did not show any difference between seven occlusion conditions on the plantar pressure distribution while standing or walking. No differences between the genders were found for any of the investigated variables. In contrast to custom-made occlusion splints, simple cotton rolls appear not to influence the neuromuscular system in a systematic manner.