Refine
Document Type
- Article (16)
Has Fulltext
- yes (16)
Is part of the Bibliography
- no (16)
Keywords
- ergonomics (3)
- inertial motion capture (3)
- Healthy adults (2)
- kinematic analysis (2)
- musculoskeletal disorders (2)
- Anatomy (1)
- Back scan (1)
- Bewegungsanalyse mit Inertialsensoren (1)
- Blocked occlusion (1)
- Body sway (1)
Institute
- Medizin (16) (remove)
Objectives: Symmetrical dental occlusion blocking is used in dentistry as a quick diagnostic tool to test for potential influences of the craniomandibular system on body sway and weight distribution. This study presents the changes of body sway and pressure distribution in healthy subjects, free of a temporomandibular dysfunction (TMD). Immediate effects between occlusal blocking and rest position on body sway and body weight distribution in general, as well as for both genders and for four age decades will be evaluated.
Materials and methods: 725 (396f/329 m) subjects (neither subjective signs of TMD nor acute/chronic complaints in the musculoskeletal system) volunteered (21 to 60 years) while both genders were divided into four age groups according to decades. A pressure measuring platform was used. Body sway and weight distribution were recorded in two dental occlusion conditions (a) in rest position and (b) symmetrical blocking (bicuspid region) by cotton rolls.
Results: Both, the frontal sway and the sagittal sway reduced by 0.67 mm (t(724) = − 3.9 (p < 0.001)) and by 0.33 mm (t(724) = − 3.4 (p < 0.001)). The relative pressure under the left forefoot increased by 0.33% (t(724) = 2.88 (p < 0.001)) and the relative pressure overall under the forefoot increased by 0.67% (t(724) = − 3.4 (p < 0.001)). Gender-specific, age-specific and BMI-specific reactions could not be identified.
Conclusions: Subjects, free of any TMD and with no complaints of the musculoskeletal system, show small changes of the body sway and weight distribution when biting symmetrically on a cotton roll. These changes are independent of age, gender or body mass index (BMI). Due to the relative large sample size, the presented results can also be seen as norm values when body sway is used as an additional assessment of a TMD.
Musculoskeletal disorders of the trunk and neck are common among cleaners. Vacuum cleaning is a demanding activity. The aim of this study was to present the movement profile of the trunk and neck during habitual vacuuming. The data were collected from 31 subjects (21f./10 m) using a 3D motion analysis system (Xsens). 10 cycles were analysed in vacuuming PVC and carpet floors with 8 vacuum cleaners. The joint angles and velocities were represented statistically descriptive. When vacuuming, the trunk is held in a forwardly inclined position by a flexion in the hip and rotated from this position. In the joint angles and velocities of the spine, the rotation proved to be dominant. A relatively large amount of movement took place in the cervical spine and also in the lumbar spine. The shown movement profile is rather a comfort area of vacuuming which may serve as a reference for ergonomics in vacuuming.
Background: In general, the prevalence of work-related musculoskeletal disorders (WMSD) in dentistry is high, and dental assistants (DA) are even more affected than dentists (D). Furthermore, differentiations between the fields of dental specialization (e.g., general dentistry, endodontology, oral and maxillofacial surgery, or orthodontics) are rare. Therefore, this study aims to investigate the ergonomic risk of the aforementioned four fields of dental specialization for D and DA on the one hand, and to compare the ergonomic risk of D and DA within each individual field of dental specialization. Methods: In total, 60 dentists (33 male/27 female) and 60 dental assistants (11 male/49 female) volunteered in this study. The sample was composed of 15 dentists and 15 dental assistants from each of the dental field, in order to represent the fields of dental specialization. In a laboratory setting, all tasks were recorded using an inertial motion capture system. The kinematic data were applied to an automated version of the Rapid Upper Limb Assessment (RULA). Results: The results revealed significantly reduced ergonomic risks in endodontology and orthodontics compared to oral and maxillofacial surgery and general dentistry in DAs, while orthodontics showed a significantly reduced ergonomic risk compared to general dentistry in Ds. Further differences between the fields of dental specialization were found in the right wrist, right lower arm, and left lower arm in DAs and in the neck, right wrist, right lower arm, and left wrist in Ds. The differences between Ds and DAs within a specialist discipline were rather small. Discussion: Independent of whether one works as a D or DA, the percentage of time spent working in higher risk scores is reduced in endodontologists, and especially in orthodontics, compared to general dentists or oral and maxillofacial surgeons. In order to counteract the development of WMSD, early intervention should be made. Consequently, ergonomic training or strength training is recommended.
In the application of range of motion (ROM) tests there is little agreement on the number of repetitions to be measured and the number of preceding warm-up protocols. In stretch training a plateau in ROM gains can be seen after four to five repetitions. With increasing number of repetitions, the gain in ROM is reduced. This study examines the question of whether such an effect occurs in common ROM tests. Twenty-two healthy sport students (10 m/12 f.) with an average age of 25.3 ± 1.94 years (average height 174.1 ± 9.8 cm; weight 66.6 ± 11.3 kg and BMI 21.9 ± 2.0 kg/cm2) volunteered in this study. Each subject performed five ROM tests in a randomized order—measured either via a tape measure or a digital inclinometer: Tape measure was used to evaluate the Fingertip-to-Floor test (FtF) and the Lateral Inclination test (LI). Retroflexion of the trunk modified after Janda (RF), Thomas test (TT) and a Shoulder test modified after Janda (ST) were evaluated with a digital inclinometer. In order to show general acute effects within 20 repetitions we performed ANOVA/Friedman-test with multiple comparisons. A non-linear regression was then performed to identify a plateau formation. Significance level was set at 5%. In seven out of eight ROM tests (five tests in total with three tests measured both left and right sides) significant flexibility gains were observed (FtF: p < 0.001; LI-left/right: p < 0.001/0.001; RF: p = 0.009; ST-left/right: p < 0.001/p = 0.003; TT-left: p < 0.001). A non-linear regression with random effects was successfully applied on FtF, RF, LI-left/right, ST-left and TT-left and thus, indicate a gradual decline in the amount of gained ROM. An acute effect was observed in most ROM tests, which is characterized by a gradual decline of ROM gain. For those tests, we can state that the acute effect described in the stretching literature also applies to the performance of typical ROM tests. Since a non-linear behavior was shown, it is the decision of the practitioner to weigh up between measurement accuracy and expenditure. Researchers and practitioners should consider this when applying ROM assessments to healthy young adults.
Background: In clinical practice range of motion (RoM) is usually assessed with low-cost devices such as a tape measure (TM) or a digital inclinometer (DI). However, the intra- and inter-rater reliability of typical RoM tests differ, which impairs the evaluation of therapy progress. More objective and reliable kinematic data can be obtained with the inertial motion capture system (IMC) by Xsens. The aim of this study was to obtain the intra- and inter-rater reliability of the TM, DI and IMC methods in five RoM tests: modified Thomas test (DI), shoulder test modified after Janda (DI), retroflexion of the trunk modified after Janda (DI), lateral inclination (TM) and fingertip-to-floor test (TM).
Methods: Two raters executed the RoM tests (TM or DI) in a randomized order on 22 healthy individuals while, simultaneously, the IMC data (Xsens MVN) was collected. After 15 warm-up repetitions, each rater recorded five measurements.
Findings: Intra-rater reliabilities were (almost) perfect for tests in all three devices (ICCs 0.886–0.996). Inter-rater reliability was substantial to (almost) perfect in the DI (ICCs 0.71–0.87) and the IMC methods (ICCs 0.61–0.993) and (almost) perfect in the TM methods (ICCs 0.923–0.961). The measurement error (ME) for the tests measured in degree (°) was 0.9–3.3° for the DI methods and 0.5–1.2° for the IMC approaches. In the tests measured in centimeters the ME was 0.5–1.3cm for the TM methods and 0.6–2.7cm for the IMC methods. Pearson correlations between the results of the DI or the TM respectively with the IMC results were significant in all tests except for the shoulder test on the right body side (r = 0.41–0.81).
Interpretation: Measurement repetitions of either one or multiple trained raters can be considered reliable in all three devices.
Background: The aim is to investigate to what extent the different oral protections compared to the habitual occlusion affect the upper body posture in statics and during taekwondo-specific movement.
Methods: 12 Taekwondoka (5 f/7 m) of German national team were measured by using a 3d back scanner and an ultrasonic distance measuring (upright stand, taekwondo attack and defense movement, two taekwondo specific combinations) in habitual occlusion, with a custom-made and ready-made mouth protection
Results: There are no significant changes in the upper body posture (p ≥ 0.05). Depending on the dynamic measurements, different significant reactions of the spinal position were found while wearing the custom made mouthguard or the ready-made mouthguard according to the conducted movement.
Conclusion: The measured changes in dynamic movements are not clinical relevant. Based on the positive responses from the participants, the custom-made mouth protection can be recommended combined with an individual analysis.