Refine
Year of publication
Document Type
- Article (28)
- Preprint (1)
- Working Paper (1)
Has Fulltext
- yes (30)
Is part of the Bibliography
- no (30)
Keywords
- Cirrhosis (4)
- Portal veins (3)
- ACLF (2)
- Biomarkers (2)
- Liver diseases (2)
- Portal hypertension (2)
- Veins (2)
- cirrhosis (2)
- portal hypertension (2)
- Acute decompensation (1)
Institute
Background Bacterial DNA containing motifs of unmethylated CpG dinucleotides (CpG-ODN) initiate an innate immune response mediated by the pattern recognition receptor Toll-like receptor 9 (TLR9). This leads in particular to the expression of proinflammatory mediators such as tumor necrosis factor (TNF-alpha) and interleukin-1beta (IL-1beta). TLR9 is expressed in human and murine pulmonary tissue and induction of proinflammatory mediators has been linked to the development of acute lung injury. Therefore, the hypothesis was tested whether CpG-ODN administration induces an inflammatory response in the lung via TLR9 in vivo. Methods Wild-type (WT) and TLR9-deficient (TLR9-D) mice received CpG-ODN intraperitoneally (1668-Thioat, 1 nmol/g BW) and were observed for up to 6 hrs. Lung tissue and plasma samples were taken and various inflammatory markers were measured. Results In WT mice, CpG-ODN induced a strong activation of pulmonary NFKB as well as a significant increase in pulmonary TNF-alpha and IL-1beta mRNA/protein. In addition, cytokine serum levels were significantly elevated in WT mice. Increased pulmonary content of lung myeloperoxidase (MPO) was documented in WT mice following application of CpG-ODN. Bronchoalveolar lavage (BAL) revealed that CpG-ODN stimulation significantly increased total cell number as well as neutrophil count in WT animals. In contrast, the CpG-ODN-induced inflammatory response was abolished in TLR9-D mice. Conclusion This study suggests that bacterial CpG-ODN causes lung inflammation via TLR9.
Zentraler Gegenstand der Tagung waren die disziplinären Aneignungen der ethnografischen Herangehensweise in der Ethnologie und der Soziologie. Der Tagungsbericht sammelt die auf der Tagung debattierten Differenzen und Ähnlichkeiten und sichtet die tiefer liegenden, systematischen Unterschiede entlang der ethnografischen Trias von Feld, Site und Gegenstand. Mit Blick auf eine geplante Folgetagung identifizieren die Autoren Schlüsselthemen für die weitere Debatte.
Bördestandorte werden wegen ihrer Fruchtbarkeit seit Menschengedenken ackerbaulich genutzt. Sie stellen heute in der Regel „ausgeräumte“ Landschaften dar, d. h. es existieren dort nur noch wenige strukturbildende Elemente. Das war nicht immer so. Erst seit Beginn der Industrialisierung und Technisierung auch im ländlichen Raum wurde aus der zur biologischen Vielfalt beitragenden Landwirtschaft ein Wirtschaftszweig, der die natürlichen Ressourcen beeinträchtigt. Das Mitteldeutsche Trockengebiet, im Regenschatten des Harzes liegend, zählt mit seinen Bördegebieten zum Typus des ländlichen Raumes mit günstigen Produktionsbedingungen in der Landwirtschaft. Die naturräumliche Entwicklung dieser Gebiete widerspricht jedoch den Zielen des Natur- und Umweltschutzes. Hier muss eine Umkehr negativer Trends bei der Bewahrung der biologischen Vielfalt bzw. dem Schutz der Ressourcen Boden, Wasser und Luft angestrebt werden.
Manipulative communications touting stocks are common in capital markets around the world. Although the price distortions created by so-called “pump-and-dump” schemes are well known, little is known about the investors in these frauds. By examining 421 “pump-and-dump” schemes between 2002 and 2015 and a proprietary set of trading records for over 110,000 individual investors from a major German bank, we provide evidence on the participation rate, magnitude of the investments, losses, and the characteristics of the individuals who invest in such schemes. Our evidence suggests that participation is quite common and involves sizable losses, with nearly 6% of active investors participating in at least one “pump-and-dump” and an average loss of nearly 30%. Moreover, we identify several distinct types of investors, some of which should not be viewed as falling prey to these frauds. We also show that portfolio composition and past trading behavior can better explain participation in touted stocks than demographics. Our analysis offers insights into the challenges associated with designing effective investor protection against market manipulation.
Background: Acoustic Radiation Force Impulse (ARFI)-imaging is an ultrasound-based elastography method enabling quantitative measurement of tissue stiffness. The aim of the present study was to evaluate sensitivity and specificity of ARFI-imaging for differentiation of thyroid nodules and to compare it to the well evaluated qualitative real-time elastography (RTE).
Methods: ARFI-imaging involves the mechanical excitation of tissue using acoustic pulses to generate localized displacements resulting in shear-wave propagation which is tracked using correlation-based methods and recorded in m/s. Inclusion criteria were: nodules $5 mm, and cytological/histological assessment. All patients received conventional ultrasound, real-time elastography (RTE) and ARFI-imaging.
Results: One-hundred-fifty-eight nodules in 138 patients were available for analysis. One-hundred-thirty-seven nodules were benign on cytology/histology, and twenty-one nodules were malignant. The median velocity of ARFI-imaging in the healthy thyroid tissue, as well as in benign and malignant thyroid nodules was 1.76 m/s, 1.90 m/s, and 2.69 m/s, respectively. While no significant difference in median velocity was found between healthy thyroid tissue and benign thyroid nodules, a significant difference was found between malignant thyroid nodules on the one hand and healthy thyroid tissue (p = 0.0019) or benign thyroid nodules (p = 0.0039) on the other hand. No significant difference of diagnostic accuracy for the diagnosis of malignant thyroid nodules was found between RTE and ARFI-imaging (0.74 vs. 0.69, p = 0.54). The combination of RTE with ARFI did not improve diagnostic accuracy.
Conclusions: ARFI can be used as an additional tool in the diagnostic work up of thyroid nodules with high negative predictive value and comparable results to RTE.
Background: Thyroid Imaging Reporting and Data System (TIRADS) was developed to improve patient management and cost-effectiveness by avoiding unnecessary fine needle aspiration biopsy (FNAB) in patients with thyroid nodules. However, its clinical use is still very limited. Strain elastography (SE) enables the determination of tissue elasticity and has shown promising results for the differentiation of thyroid nodules.
Methods: The aim of the present study was to evaluate the interobserver agreement (IA) of TIRADS developed by Horvath et al. and SE. Three blinded observers independently scored stored images of TIRADS and SE in 114 thyroid nodules (114 patients). Cytology and/or histology was available for all benign (n = 99) and histology for all malignant nodules (n = 15).
Results: The IA between the 3 observers was only fair for TIRADS categories 2–5 (Coheńs kappa = 0.27,p = 0.000001) and TIRADS categories 2/3 versus 4/5 (ck = 0.25,p = 0.0020). The IA was substantial for SE scores 1–4 (ck = 0.66,p<0.000001) and very good for SE scores 1/2 versus 3/4 (ck = 0.81,p<0.000001). 92–100% of patients with TIRADS-2 had benign lesions, while 28–42% with TIRADS-5 had malignant cytology/histology. The negative-predictive-value (NPV) was 92–100% for TIRADS using TIRADS-categories 4&5 and 96–98% for SE using score ES-3&4 for the diagnosis of malignancy, respectively. However, only 11–42% of nodules were in TIRADS-categories 2&3, as compared to 58–60% with ES-1&2.
Conclusions: IA of TIRADS developed by Horvath et al. is only fair. TIRADS and SE have high NPV for excluding malignancy in the diagnostic work-up of thyroid nodules.
Background Osseointegration is crucial for the long-term success of dental implants and depends on the tissue reaction at the tissue-implant interface. Mechanical properties and biocompatibility make zirconia a suitable material for dental implants, although surface processings are still problematic. The aim of the present study was to compare osteoblast behavior on structured zirconia and titanium surfaces under standardized conditions. Methods The surface characteristics were determined by scanning electron microscopy (SEM). In primary bovine osteoblasts attachment kinetics, proliferation rate and synthesis of bone-associated proteins were tested on different surfaces. Results The results demonstrated that the proliferation rate of cells was significantly higher on zirconia surfaces than on titanium surfaces (p < 0.05; Student's t-test). In contrast, attachment and adhesion strength of the primary cells was significant higher on titanium surfaces (p < 0.05; U test). No significant differences were found in the synthesis of bone-specific proteins. Ultrastructural analysis revealed phenotypic features of osteoblast-like cells on both zirconia and titanium surfaces. Conclusion The study demonstrates distinct effects of the surface composition on osteoblasts in culture. Zirconia improves cell proliferation significantly during the first days of culture, but it does not improve attachment and adhesion strength. Both materials do not differ with respect to protein synthesis or ultrastructural appearance of osteoblasts. Zirconium oxide may therefore be a suitable material for dental implants.
Background Titanium and titanium alloys are widely used for fabrication of dental implants. Since the material composition and the surface topography of a biomaterial play a fundamental role in osseointegration, various chemical and physical surface modifications have been developed to improve osseous healing. Zirconia-based implants were introduced into dental implantology as an altenative to titanium implants. Zirconia seems to be a suitable implant material because of its tooth-like colour, its mechanical properties and its biocompatibility. As the osseointegration of zirconia implants has not been extensively investigated, the aim of this study was to compare the osseous healing of zirconia implants with titanium implants which have a roughened surface but otherwise similar implant geometries. Methods Forty-eight zirconia and titanium implants were introduced into the tibia of 12 minipigs. After 1, 4 or 12 weeks, animals were sacrificed and specimens containing the implants were examined in terms of histological and ultrastructural techniques. Results Histological results showed direct bone contact on the zirconia and titanium surfaces. Bone implant contact as measured by histomorphometry was slightly better on titanium than on zirconia surfaces. However, a statistically significant difference between the two groups was not observed. Conclusion The results demonstrated that zirconia implants with modified surfaces result in an osseointegration which is comparable with that of titanium implants.
Background The successful use of zirconia ceramics in orthopedic surgery led to a demand for dental zirconium-based implant systems. Because of its excellent biomechanical characteristics, biocompatibility, and bright tooth-like color, zirconia (zirconium dioxide, ZrO2) has the potential to become a substitute for titanium as dental implant material. The present study aimed at investigating the osseointegration of zirconia implants with modified ablative surface at an ultrastructural level. Methods A total of 24 zirconia implants with modified ablative surfaces and 24 titanium implants all of similar shape and surface structure were inserted into the tibia of 12 Gottinger minipigs. Block biopsies were harvested 1 week, 4 weeks or 12 weeks (four animals each) after surgery. Scanning electron microscopy (SEM) analysis was performed at the bone implant interface. Results Remarkable bone attachment was already seen after 1 week which increased further to intimate bone contact after 4 weeks, observed on both zirconia and titanium implant surfaces. After 12 weeks, osseointegration without interposition of an interfacial layer was detected. At the ultrastructural level, there was no obvious difference between the osseointegration of zirconia implants with modified ablative surfaces and titanium implants with a similar surface topography. Conclusion The results of this study indicate similar osseointegration of zirconia and titanium implants at the ultrastructural level.
Due to an increasing awareness of the potential hazardousness of air pollutants, new laws, rules and guidelines have recently been implemented globally. In this respect, numerous studies have addressed traffic-related exposure to particulate matter using stationary technology so far. By contrast, only few studies used the advanced technology of mobile exposure analysis. The Mobile Air Quality Study (MAQS) addresses the issue of air pollutant exposure by combining advanced high-granularity spatial-temporal analysis with vehicle-mounted, person-mounted and roadside sensors. The MAQS-platform will be used by international collaborators in order 1) to assess air pollutant exposure in relation to road structure, 2) to assess air pollutant exposure in relation to traffic density, 3) to assess air pollutant exposure in relation to weather conditions, 4) to compare exposure within vehicles between front and back seat (children) positions, and 5) to evaluate "traffic zone"- exposure in relation to non-"traffic zone"-exposure. Primarily, the MAQS-platform will focus on particulate matter. With the establishment of advanced mobile analysis tools, it is planed to extend the analysis to other pollutants including including NO2, SO2, nanoparticles, and ozone.