Refine
Year of publication
Document Type
- Preprint (579)
- Article (370)
- Working Paper (3)
- Conference Proceeding (2)
- Part of a Book (1)
Language
- English (955) (remove)
Has Fulltext
- yes (955) (remove)
Is part of the Bibliography
- no (955)
Keywords
- Heavy Ion Experiments (18)
- Hadron-Hadron scattering (experiments) (11)
- Heavy-ion collision (6)
- LHC (6)
- Kollisionen schwerer Ionen (5)
- Hadron-Hadron Scattering (4)
- Quark-Gluon Plasma (4)
- heavy ion collisions (4)
- ALICE experiment (3)
- Heavy Ions (3)
Institute
- Physik (909)
- Frankfurt Institute for Advanced Studies (FIAS) (811)
- Informatik (775)
- Medizin (33)
- Center for Financial Studies (CFS) (3)
- ELEMENTS (3)
- Hochschulrechenzentrum (3)
- Informatik und Mathematik (3)
- Wirtschaftswissenschaften (3)
- Biowissenschaften (2)
- E-Finance Lab e.V. (2)
- Georg-Speyer-Haus (2)
- Geowissenschaften / Geographie (2)
- Helmholtz International Center for FAIR (2)
- House of Finance (HoF) (2)
- Pharmazie (2)
- Sustainable Architecture for Finance in Europe (SAFE) (2)
- Biochemie und Chemie (1)
- Biochemie, Chemie und Pharmazie (1)
- Deutsches Institut für Internationale Pädagogische Forschung (DIPF) (1)
- Frankfurt MathFinance Institute (FMFI) (1)
- Institut für Ökologie, Evolution und Diversität (1)
- Psychologie (1)
- Sportwissenschaften (1)
An experiment addressing electron capture (EC) decay of hydrogen-like 142Pm60+ions has been conducted at the experimental storage ring (ESR) at GSI. The decay appears to be purely exponential and no modulations were observed. Decay times for about 9000 individual EC decays have been measured by applying the single-ion decay spectroscopy method. Both visually and automatically analysed data can be described by a single exponential decay with decay constants of 0.0126(7)s−1 for automatic analysis and 0.0141(7)s−1 for manual analysis. If a modulation superimposed on the exponential decay curve is assumed, the best fit gives a modulation amplitude of merely 0.019(15), which is compatible with zero and by 4.9 standard deviations smaller than in the original observation which had an amplitude of 0.23(4).
The radiative electron capture (REC) into the K shell of bare Xe ions colliding with a hydrogen gas target has been investigated. In this study, the degree of linear polarization of the K-REC radiation was measured and compared with rigorous relativistic calculations as well as with the previous results recorded for U92+. Owing to the improved detector technology, a significant gain in precision of the present polarization measurement is achieved compared to the previously published results. The obtained data confirms that for medium-Z ions such as Xe, the REC process is a source of highly polarized x rays which can easily be tuned with respect to the degree of linear polarization and the photon energy. We argue, in particular, that for relatively low energies the photons emitted under large angles are almost fully linear polarized.
A wide variety of enzymatic pathways that produce specialized metabolites in bacteria, fungi and plants are known to be encoded in biosynthetic gene clusters. Information about these clusters, pathways and metabolites is currently dispersed throughout the literature, making it difficult to exploit. To facilitate consistent and systematic deposition and retrieval of data on biosynthetic gene clusters, we propose the Minimum Information about a Biosynthetic Gene cluster (MIBiG) data standard.
A central motivation for the development of x-ray free-electron lasers has been the prospect of time-resolved single-molecule imaging with atomic resolution. Here, we show that x-ray photoelectron diffraction—where a photoelectron emitted after x-ray absorption illuminates the molecular structure from within—can be used to image the increase of the internuclear distance during the x-ray-induced fragmentation of an O2 molecule. By measuring the molecular-frame photoelectron emission patterns for a two-photon sequential K-shell ionization in coincidence with the fragment ions, and by sorting the data as a function of the measured kinetic energy release, we can resolve the elongation of the molecular bond by approximately 1.2 a.u. within the duration of the x-ray pulse. The experiment paves the road toward time-resolved pump-probe photoelectron diffraction imaging at high-repetition-rate x-ray free-electron lasers.
The electron-capture process was studied for Xe54+ colliding with H2 molecules at the internal gas target of the Experimental Storage Ring (ESR) at GSI, Darmstadt. Cross-section values for electron capture into excited projectile states were deduced from the observed emission cross section of Lyman radiation, being emitted by the hydrogenlike ions subsequent to the capture of a target electron. The ion beam energy range was varied between 5.5 and 30.9 MeV/u by applying the deceleration mode of the ESR. Thus, electron-capture data were recorded at the intermediate and, in particular, the low-collision-energy regime, well below the beam energy necessary to produce bare xenon ions. The obtained data are found to be in reasonable qualitative agreement with theoretical approaches, while a commonly applied empirical formula significantly overestimates the experimental findings.