Refine
Document Type
- Article (2)
Language
- English (2)
Has Fulltext
- yes (2)
Is part of the Bibliography
- no (2)
Keywords
- ICL (1)
- ICL V4c (1)
- Myopia (1)
- Phakic (1)
- anterior chamber depth changes (1)
- cataract surgery (1)
- effective lens position (1)
- pIOL (1)
- pseudoexfoliative syndrome (1)
Institute
- Medizin (2)
Purpose: To compare the effective lens position (ELP), anterior chamber depth (ACD) changes, and visual outcomes in patients with and without pseudoexfoliation syndrome (PEX) after cataract surgery.
Design: Prospective, randomized, fellow-eye controlled clinical case series.
Methods: This prospective comparative case series enrolled 56 eyes of 56 consecutive patients with (n = 28) or without PEX (n = 28) and clinically significant cataract who underwent standard phacoemulsification and were implanted with single-piece acrylic posterior chamber intraocular lenses (IOLs). The primary outcome parameters were the ACD referring to the distance between the corneal anterior surface and the lens anterior surface, which is an indicator of the postoperative axial position of the IOL (the so-called ELP) and distance corrected visual acuity (DCVA).
Results: Before surgery, the ACD was 2.54 ± 0.42 mm in the PEX group and 2.53 ± 0.38 mm in the control group (p = 0.941). Postoperatively, the ACD was 4.29 ± 0.71 mm in the PEX group and 4.33 ± 0.72 mm in the normal group, respectively (p = 0.533). There was no significant difference in ACD changes between groups (PEX group: 1.75 ± 0.74 mm, control group: 1.81 ± 0.61 mm, p = 0.806) and DCVA pre- (p = 0.469) and postoperatively (PEX group: 0.11 ± 0.13 logMAR, control group: 0.09 ± 0.17 logMAR, p = 0.245) between groups.
Conclusion: Preoperative and postoperative ACD, as an indicator of ELP, between PEX eyes and healthy eyes after cataract surgery showed no significant difference. Phacoemulsification induced similar changes in eyes with PEX compared to healthy eyes.
Purpose: To evaluate intermediate and long-term visual outcomes and safety of a phakic intraocular posterior chamber lens with a central hole (ICL V4c) for myopic eyes.
Methods: Retrospective, consecutive case study of patients that uneventfully received a ICL V4c for myopia correction, with a 5-year postoperative follow-up. Department of Ophthalmology, Goethe University Frankfurt, Germany.
Results: From 241 eyes that underwent ICL implantation, we included 45 eyes with a mean age at surgery of 33 years ± 6 (18–48 years), with a 5 years follow-up. CDVA improved from 0.05logMAR ± 0.15 CDVA preoperatively to − 0.00 ± 0,07 at 5 years and did not change significantly from 3 to 5 years’ time (p = 0.266). The mean spherical equivalent (SE) improved from -10.13D ± 3.39 to − 0.45D ± 0.69. The change in endothelial cell count showed a mean decrease of 1.9% per year throughout the follow-up. Safety and efficacy index were 1.16 and 0.78, respectively. Cataract formation was seen in 2 of 241 eyes (0.8%), but in none of the 45 eyes that finished the 5-year follow-up.
Conclusions: Our data show a good intermediate and long-term stability, efficiency, and safety of ICL V4c phakic lenses in myopic eyes comparable to other known literature.