Refine
Year of publication
Document Type
- Article (50)
- Preprint (2)
- Conference Proceeding (1)
Language
- English (53)
Has Fulltext
- yes (53)
Is part of the Bibliography
- no (53)
Keywords
- 140Ce (1)
- MACS (1)
- capture (1)
- cerium (1)
- cross-section (1)
- n_TOF (1)
- neutron (1)
- nucleosynthesis (1)
- s-process (1)
Institute
- Physik (52)
- Biochemie, Chemie und Pharmazie (1)
Setup for the measurement of the 235U(n,f) cross section relative to n-p scattering up to 1 GeV
(2020)
The neutron induced fission of 235U is extensively used as a reference for neutron fluence measurements in various applications, ranging from the investigation of the biological effectiveness of high energy neutrons, to the measurement of high energy neutron cross sections of relevance for accelerator driven nuclear systems. Despite its widespread use, no data exist on neutron induced fission of 235U above 200 MeV. The neutron facility n_TOF offers the possibility to improve the situation. The measurement of 235U(n,f) relative to the differential n-p scattering cross-section, was carried out in September 2018 with the aim of providing accurate and precise cross section data in the energy range from 10 MeV up to 1 GeV. In such measurements, Recoil Proton Telescopes (RPTs) are used to measure the neutron flux while the fission events are detected and counted with dedicated detectors. In this paper the measurement campaign and the experimental set-up are illustrated.
Since the start of its operation in 2001, based on an idea of Prof. Carlo Rubbia [1], the neutron time of-flight facility of CERN, n_TOF, has become one of the most forefront neutron facilities in the world for wide-energy spectrum neutron cross section measurements. Thanks to the combination of excellent neutron energy resolution and high instantaneous neutron flux available in the two experimental areas, the second of which has been constructed in 2014, n_TOF is providing a wealth of new data on neutron-induced reactions of interest for nuclear astrophysics, advanced nuclear technologies and medical applications. The unique features of the facility will continue to be exploited in the future, to perform challenging new measurements addressing the still open issues and long-standing quests in the field of neutron physics. In this document the main characteristics of the n_TOF facility and their relevance for neutron studies in the different areas of research will be outlined, addressing the possible future contribution of n_TOF in the fields of nuclear astrophysics, nuclear technologies and medical applications. In addition, the future perspectives of the facility will be described including the upgrade of the spallation target, the setup of an imaging installation and the construction of a new irradiation area.
We have measured the γ-rays following neutron capture on 240Pu and 244 Cm at the n_TOF facility at CERN with the Total Absorption Calorimeter (TAC) and with C6D6 organic scintillators. The TAC is made of 40 BaF2 crystals operating in coincidence and covering almost the entire solid angle. This allows to obtain information concerning the energy spectra and the multiplicity of the measured capture γ-ray cascades. Additional information is also obtained from the C6D6 detectors. We have analyzed the measured data in order to draw conclusions about the Photon Strength Functions (PSFs) of 241Pu and 245Cm below their neutron separation energies. The analysis has been performed by fitting the PSFs to the experimental results, using the differential evolution method, in order to find neutron capture cascades capable of reproducing at the same time a great variety of deposited energy spectra.
Neutron-induced fission cross sections of isotopes involved in the nuclear fuel cycle are vital for the design and safe operation of advanced nuclear systems. Such experimental data can also provide additional constraints for the adjustment of nuclear model parameters used in the evaluation process, resulting in the further development of fission models. In the present work, the 237Np(n,f) cross section was studied at the EAR2 vertical beam-line at CERN's n_TOF facility, over a wide range of neutron energies, from meV to MeV, using the time-of-flight technique and a set-up based on Micromegas detectors, in an attempt to provide accurate experimental data. Preliminary results in the 200 keV – 14 MeV neutron energy range as well as the experimental procedure, including a description of the facility and the data handling and analysis, will be presented.
The (n, γ) cross sections of the gadolinium isotopes play an important role in the study of the stellar nucleosynthesis. In particular, among the isotopes heavier than Fe, 154Gd together with 152Gd have the peculiarity to be mainly produced by the slow capture process, the so-called s-process, since they are shielded against the β-decay chains from the r-process region by their stable samarium isobars. Such a quasi pure s-process origin makes them crucial for testing the robustness of stellar models in galactic chemical evolution (GCE). According to recent models, the 154Gd and 152Gd abundances are expected to be 15-20% lower than the reference un-branched s-process 150Sm isotope. The close correlation between stellar abundances and neutron capture cross sections prompted for an accurate measurement of 154Gd cross section in order to reduce the uncertainty attributable to nuclear physics input and eventually rule out one of the possible causes of present discrepancies between observation and model predictions. To this end, the neutron capture cross section of 154Gd was measured in a wide neutron energy range (from thermal up to some keV) with high resolution in the first experimental area of the neutron time-of-flight facility n_TOF (EAR1) at CERN. In this contribution, after a brief description of the motivation and of the experimental setup used in the measurement, the preliminary results of the 154Gd neutron capture reaction as well as their astrophysical implications are presented.
The 236U isotope plays an important role in nuclear systems, both for future and currently operating ones. The actual knowledge of the capture reaction of this isotope is satisfactory in the thermal region, but it is considered insufficient for Fast Reactor and ADS applications. For this reason the 236U(n, γ) reaction cross-section has been measured for the first time in the whole energy region from thermal energy up to 1 MeV at the n_TOF facility with two different detection systems: an array of C6D6 detectors, employing the total energy deposited method, and a FX1 total absorption calorimeter (TAC), made of 40 BaF2 crystals. The two n_TOF data sets agree with each other within the statistical uncertainty in the Resolved Resonance Region up to 800 eV, while sizable differences (up to ≃ 20%) are found relative to the current evaluated data libraries. Moreover two new resonances have been found in the n_TOF data. In the Unresolved Resonance Region up to 200 keV, the n_TOF results show a reasonable agreement with previous measurements and evaluated data.
The 33S(n,α)30Si cross section measurement, using 10B(n,α) as reference, at the n_TOF Experimental Area 2 (EAR2) facility at CERN is presented. Data from 0.01 eV to 100 keV are provided and, for the first time, the cross section is measured in the range from 0.01 eV to 10 keV. These data may be used for a future evaluation of the cross section because present evaluations exhibit large discrepancies. The 33S(n,α)30Si reaction is of interest in medical physics because of its possible use as a cooperative target to boron in Neutron Capture Therapy (NCT).
he study of the resonant structures in neutron-nucleus cross-sections, and therefore of the compound-nucleus reaction mechanism, requires spectroscopic measurements to determine with high accuracy the energy of the neutron interacting with the material under study.
To this purpose, the neutron time-of-flight facility n_TOF has been operating since 2001 at CERN. Its characteristics, such as the high intensity instantaneous neutron flux, the wide energy range from thermal to few GeV, and the very good energy resolution, are perfectly suited to perform high-quality measurements of neutron-induced reaction cross sections. The precise and accurate knowledge of these cross sections plays a fundamental role in nuclear technologies, nuclear astrophysics and nuclear physics.
Two different measuring stations are available at the n_TOF facility, called EAR1 and EAR2, with different characteristics of intensity of the neutron flux and energy resolution. These experimental areas, combined with advanced detection systems lead to a great flexibility in performing challenging measurement of high precision and accuracy, and allow the investigation isotopes with very low cross sections, or available only in small quantities, or with very high specific activity.
The characteristics and performances of the two experimental areas of the n_TOF facility will be presented, together with the most important measurements performed to date and their physics case. In addition, the significant upcoming measurements will be introduced.
Neutron-induced reaction cross sections are important for a wide variety of research fields ranging from the study of nuclear level densities, nucleosynthesis to applications of nuclear technology like design, and criticality and safety assessment of existing and future nuclear reactors, radiation dosimetry, medical applications, nuclear waste transmutation, accelerator-driven systems and fuel cycle investigations. Simulations and calculations of nuclear technology applications largely rely on evaluated nuclear data libraries. The evaluations in these libraries are based both on experimental data and theoretical models. CERN’s neutron time-of-flight facility n_TOF has produced a considerable amount of experimental data since it has become fully operational with the start of its scientific measurement programme in 2001. While for a long period a single measurement station (EAR1) located at 185 m from the neutron production target was available, the construction of a second beam line at 20 m (EAR2) in 2014 has substantially increased the measurement capabilities of the facility. An outline of the experimental nuclear data activities at n_TOF will be presented.
The CERN n_TOF neutron beam facility is characterized by a very high instantaneous neutron flux, excellent TOF resolution at the 185 m long flight path (EAR-1), low intrinsic background and coverage of a wide range of neutron energies, from thermal to a few GeV. These characteristics provide a unique possibility to perform high-accuracy measurements of neutron-induced reaction cross-sections and angular distributions of interest for fundamental and applied Nuclear Physics. Since 2001, the n_TOF Collaboration has collected a wealth of high quality nuclear data relevant for nuclear astrophysics, nuclear reactor technology, nuclear medicine, etc. The overall efficiency of the experimental program and the range of possible measurements has been expanded with the construction of a second experimental area (EAR-2), located 20 m on the vertical of the n_TOF spallation target. This upgrade, which benefits from a neutron flux 30 times higher than in EAR-1, provides a substantial extension in measurement capabilities, opening the possibility to collect data on neutron cross-section of isotopes with short half-lives or available in very small amounts. This contribution will outline the main characteristics of the n_TOF facility, with special emphasis on the new experimental area. In particular, we will discuss the innovative features of the EAR-2 neutron beam that make possible to perform very challenging measurements on short-lived radioisotopes or sub-mg samples, out of reach up to now at other neutron facilities around the world. Finally, the future perspectives of the facility will be presented.