Refine
Document Type
- Article (30)
Language
- English (30)
Has Fulltext
- yes (30)
Is part of the Bibliography
- no (30)
Keywords
- Branching fraction (5)
- BESIII (2)
- CBA (2)
- Charmed mesons (2)
- Electroweak interaction (2)
- Hadronic decays (2)
- IL-6 (2)
- Lepton colliders (2)
- Leptonic, semileptonic & radiative decays (2)
- Particle decays (2)
Institute
- Physik (17)
- Medizin (10)
- Frankfurt Institute for Advanced Studies (FIAS) (1)
- Informatik (1)
Introduction: For management of complicated retinal detachments, a pars plana vitrectomy with temporary silicone oil (SO) fill is the method of choice. According to literature, the retinal redetachment rate varies between <10% and >70% with around 36% in our own group (retrospective data analysis, n = 119 eyes).
Methods: The main goal was to reduce the retinal redetachment rate. Standard operating procedures (SOPs) and evaluation protocols (EVALPs) were developed to prospectively analyse risk factors. Lab analysis of SO was performed, and the role of surgical experience was evaluated and investigated with Eyesi®.
Results: We achieved a significant reduction of the retinal redetachment rate (to 6.80%, n = 101, p = 0.002). After surgery with SO injection, neither further membrane peeling (in 16.5%) nor retinal laser coagulation (in 100%) during revision surgery had a significant effect on the reattachment rate (p = 0.167, p = 0.23), while extensive additional laser coagulation reduced visual acuity (p = 0.01). A 3-port approach had to be set up to complete SO removal. A difference in success rate depending on surgical experience was confirmed, and the performance in Eyesi correlated with that in the patients' eye.
Conclusions: A SOP- and EVALP-based management and new strategies to secure the surgical performance seem to be essential for successful surgery.
Aims: The ILUVIEN Registry Safety Study is an ongoing, multicentre, open-label, observational study collecting real-world data on the safety and effectiveness of the 0.2 µg/day fluocinolone acetonide (FAc) implant in patients treated according to the European label requirements.
Methods: Patients included in this analysis were treated for the licensed indication of chronic diabetic macular oedema (cDMO; that is, DMO that persists or recurs despite treatment). Data presented in the current analysis were collected from patient records up to 6 March 2017. Visual acuity (VA) data, including mean change in VA over time and at last observation, intraocular pressure (IOP) over the course of the study, IOP events, use of IOP-lowering therapy and cup:disc ratio were analysed. Information on additional DMO treatments post-FAc implant was also captured.
Results: Five hundred and sixty-three patients (593 eyes) were enrolled on the study. Mean IOP for the overall population remained within the normal range throughout follow-up and 76.7% of patients did not require IOP-lowering therapy following treatment with the FAc implant. Sixty-nine per cent of eyes did not require additional DMO treatments. Mean VA in the overall population increased from 51.9 letters at baseline to 55.6 letters at month 12, with a significant increase of 2.9 letters at last observation. Patients with short-term cDMO experienced greater VA gains than those with long-term cDMO.
Conclusions: The results of this analysis are comparable with those of other studies, including the Fluocinolone Acetate for Macular Edema study. The study reinforces the good safety and effectiveness profile of FAc, and demonstrates the benefit of early FAc treatment.
Purpose: There are little or no published data comparing the outcomes of ILUVIEN® (0.19 mg fluocinolone acetonide [FAc]) and OZURDEX® (0.7 mg dexamethasone [DEX]) implants in patients with diabetic macular edema (DME), and this case sought to compare their outcomes.
Methods: This case was extracted from a monocentric audit involving a pool of 25 patients (33 eyes) with DME and treated with a single FAc implant between October 2013 and December 2016. This case, a 61-year-old male with a pseudophakic lens, is from a patient that had received 4 intravitreal injections of a DEX implant prior to FAc implant and then was monitored for 3 years until re-treatment with a second FAc implant. Parameters measured included visual acuity (VA), central retinal thickness (CRT), and intraocular pressure (IOP).
Results: After the DEX implants, CRT transiently improved. In March 2014, the decision was taken to administer an FAc implant, and this led to a reduction in CRT below 300 µm (from a baseline of 748 µm), and this was sustained for 30 months. VA remained above 65 Early Treatment Diabetic Retinopathy Study letters to month 36, after which time a second FAc implant (in April 2017) was administered due to recurrence of edema and CRT decreased to below 300 µm and VA improved to 70 letters. Side effects included elevated IOP, which was effectively managed with IOP-lowering drops.
Conclusion: A single injection of FAc implant led to sustained improvements in CRT and VA that lasted for between 30 and 36 months, which is in contrast to the DEX implant where re-treatment was generally required within 6–7 months. After 36 months, re-treatment with the FAc implant again led to improved VA and CRT, and responses that were similar to those achieved with the first FAc implant.
Using a data sample of e+e− collision data corresponding to an integrated luminosity of 2.93 fb−1 collected with the BESIII detector at a center-of-mass energy of s=3.773GeV, we search for the singly Cabibbo-suppressed decays D0→π0π0π0, π0π0η, π0ηη and ηηη using the double tag method. The absolute branching fractions are measured to be B(D0→π0π0π0)=(2.0±0.4±0.3)×10−4, B(D0→π0π0η)=(3.8±1.1±0.7)×10−4 and B(D0→π0ηη)=(7.3±1.6±1.5)×10−4 with the statistical significances of 4.8σ, 3.8σ and 5.5σ, respectively, where the first uncertainties are statistical and the second ones systematic. No significant signal of D0→ηηη is found, and the upper limit on its decay branching fraction is set to be B(D0→ηηη)<1.3×10−4 at the 90% confidence level.
Using 10.1 × 109 J/ψ events produced by the Beijing Electron Positron Collider (BEPCII) at a center-of-mass energy √s = 3.097 GeV and collected with the BESIII detector, we present a search for the rare semi-leptonic decay J/ψ → D−e+νe + c.c. No excess of signal above background is observed, and an upper limit on the branching fraction ℬ(J/ψ → D−e+νe + c. c.) < 7.1 × 10−8 is obtained at 90% confidence level. This is an improvement of more than two orders of magnitude over the previous best limit.
The process e+e−→ϕη is studied at 22 center-of-mass energy points (√s) between 2.00 and 3.08 GeV using 715 pb−1 of data collected with the BESIII detector. The measured Born cross section of e+e−→ϕη is found to be consistent with BABAR measurements, but with improved precision. A resonant structure around 2.175 GeV is observed with a significance of 6.9σ with mass (2163.5±6.2±3.0) MeV/c2 and width (31.1+21.1−11.6±1.1) MeV, where the first uncertainties are statistical and the second are systematic.
We measure the inclusive semielectronic decay branching fraction of the D+s meson. A double-tag technique is applied to e+e− annihilation data collected by the BESIII experiment at the BEPCII collider, operating in the center-of-mass energy range 4.178–4.230 GeV. We select positrons fromD+s→Xe+νe with momenta greater than 200 MeV/c and determine the laboratory momentum spectrum, accounting for the effects of detector efficiency and resolution. The total positron yield and semielectronic branching fraction are determined by extrapolating this spectrum below the momentum cutoff. We measure the D+s semielectronic branching fraction to be(6.30±0.13(stat.)±0.09(syst.)±0.04(ext.))%, showing no evidence for unobserved exclusive semielectronic modes. We combine this result with external data taken from literature to determine the ratio of the D+s and D0 semielectronic widths, Γ(D+s→Xe+νe)Γ(D0→Xe+νe)=0.790±0.016(stat.)±0.011(syst.)±0.016(ext.). Our results are consistent with and more precise than previous measurements.
Relative fractions and phases of the intermediate decays are determined. With the detection efficiency estimated by the results of the amplitude analysis, the branching fraction of Dþ s → K−Kþπþπ0 decay is measured to be ð5.42 0.10stat 0.17systÞ%.
Using data samples collected with the BESIII detector operating at the BEPCII storage ring at center-of-mass energies from 4.178 to 4.600 GeV, we study the process eþe− → π0Xð3872Þγ and search for Zcð4020Þ0 → Xð3872Þγ. We find no significant signal and set upper limits on σðeþe− → π0Xð3872ÞγÞ · BðXð3872Þ → πþπ−J=ψÞ and σðeþe− → π0Zcð4020Þ0Þ · BðZcð4020Þ0 → Xð3872ÞγÞ · BðXð3872Þ → πþπ−J=ψÞ for each energy point at 90% confidence level, which is of the order of several tenths pb.
Based on an e+e− collision data sample corresponding to an integrated luminosity of 2.93 fb−1 collected with the BESIII detector at √s=3.773 GeV, the first amplitude analysis of the singly Cabibbo-suppressed decay D+→K+K0Sπ0 is performed. From the amplitude analysis, the K∗(892)+K0S component is found to be dominant with a fraction of (57.1±2.6±4.2)%, where the first uncertainty is statistical and the second systematic. In combination with the absolute branching fraction B(D+→K+K0Sπ0) measured by BESIII, we obtain B(D+→K∗(892)+K0S)=(8.69±0.40±0.64±0.51)×10−3, where the third uncertainty is due to the branching fraction B(D+→K+K0Sπ0). The precision of this result is significantly improved compared to the previous measurement. This result also differs from most of theoretical predictions by about 4σ, which may help to improve the understanding of the dynamics behind.