Refine
Document Type
- Article (4)
- Conference Proceeding (2)
- Working Paper (2)
- Report (1)
Has Fulltext
- yes (9)
Is part of the Bibliography
- no (9)
Keywords
- chronic kidney disease (CKD) (1)
- dialysis (1)
- parathormone (PTH) (1)
- paricalcitol (1)
- predialysis (1)
- secondary hyperparathyroidism (sHPT) (1)
Paricalcitol is approved for prevention and therapy of secondary hyperparathyroidism (sHPT) in patients with chronic kidney disease (CKD), with only short-term data in clinical routine settings. A 12-month observational study was conducted in Germany and Austria (90 centers, 761 patients) from 2008 to 2013. Laboratory values, demographical, and clinical data were documented in 629 dialysis patients and 119 predialysis patients. In predialysis patients, median intact parathormone (iPTH) was 180.0 pg/mL (n = 105) at the start of the study, 115.7 pg/mL (n = 105) at last documentation, and 151.8 pg/mL (n = 50) at month 12, with 32.4% of the last documented iPTH values in the KDOQI (Kidney Disease Outcomes Quality Initiative) target range. In dialysis patients, median iPTH was 425.5 pg/mL (n = 569) at study start, 262.3 pg/mL (n = 569) at last documentation, and 266.1 pg/mL (n = 318) at month 12, with 36.5% of dialysis patients in the KDOQI target range. Intravenous paricalcitol showed more homogenous iPTH control than oral treatment. Combined analysis of all dialysis patients indicated comparable and stable mean serum calcium and phosphate levels throughout the study. Clinical symptoms, such as itching, bone pain, and fatigue, were improved compared with study entry. The spectrum and frequency of adverse events mirrored the known pattern for patients on dialysis. Paricalcitol is efficacious and has a consistent safety profile in sHPT over 12 months.
A new method of measuring quality factors in cavities is presented. This method is well suited to measure quality factors in undamped cavities as well as in heavily damped cavities, and in addition this method provides a possibility of separating modes and measuring quality factors especially in cases of overlapping modes. Measurements have been carried out on HOM-damped cavities for the DESY/THD linear collider project. Results are presented.
Damping cells for the higher order modes are necessary for the S-band linear collider to minimize BBU (Beam-Break-Up). The construction of the damper cells has to take into account the different field geometries of the higher order modes. So two different types of dampers have been designed: a wall slotted an an iris slotted cell. In order to optimize the two types of damping cells with respect to damping strength, impedance matching between coupling system and waveguide dampers and between damping cell and undamped cells and the tuning system, damping cells of both types have been built and examinated.
A new method for the determination of S-matrices of devices in multimoded waveguides and first experimental experiences are presented. The theoretical foundations are given. The scattering matrix of a TESLA copper cavity at a frequency above the cut-off of the second waveguide mode has been measured.
The effect of a single HOM-damper cell within a channel of undamped cells is described theoretically using an equivalent circuit model. From this a simple equation can be derived which relates the Q-value of the single damping-cell, the bandwidth of the passband under consideration, and the additional phase shift which is introduced by the damper cell to provide energy flow into the damper cell. This equation immediately shows the limitations of such single cell damping systems. Comparisons with experimental results are shown.
Mode propagation in an iris type accelerator section loaded with single heavily HOM-damped cells
(1994)
The wakefield effects in accelerator sections for future linear colliders will be reduced either by damping by detuning or by a combination of both. For the DESY/THD linac [1] it is forseen to employ heavily HOM-damped cells to provide a strong coupling to the TE/TM11-dipole passband as well as to the TM/TE11-dipole passband. For our experiments we have used wall-slotted damping cells. This leads to several problems concerning the propagation of fundamental and HOM-modes. Experimental investigations have been done. Results are presented.
A new method for measuring quality factors in cavities is presented. This method is capable of measuring Q-factors in heavily damped as well as in undamped cavities. In addition, the possibility of separating overlapping modes and measuring their Q-factors is provided. Measurements on HOM (higher order mode) damped cavities for the DESY/THD linear collider project are presented