Bilateral simultaneous cochlear implantation is a safe method of hearing rehabilitation in adults
(2023)
Purpose: Bilateral cochlear implantation is an effective treatment for patients with bilateral profound hearing loss. In contrast to children, adults mostly choose a sequential surgery. This study addresses whether simultaneous bilateral CI is associated with higher rates of complications compared to sequential implantation.
Methods: 169 bilateral CI surgeries were analyzed retrospectively. 34 of the patients were implanted simultaneously (group 1), whereas 135 patients were implanted sequentially (group 2). The duration of surgery, the incidence of minor and major complications and the duration of hospitalization of both groups were compared.
Results: In group 1, the total operating room time was significantly shorter. The incidences of minor and major surgical complications showed no statistically significant differences. A fatal non-surgical complication in group 1 was particularly extensively reappraised without evidence of a causal relationship to the chosen mode of care. The duration of hospitalization was 0.7 days longer than in unilateral implantation but 2.8 days shorter than the combined two hospital stays in group 2.
Conclusion: In the synopsis of all considered complications and complication-relevant factors, equivalence of simultaneous and sequential cochlear implantation in adults in terms of safety was found. However, potential side effects related to longer surgical time in simultaneous surgery must be considered individually. Careful patient selection with special consideration to existing comorbidities and preoperative anesthesiologic evaluation is essential.
Purpose: Monocentric, prospective study to investigate whether concomitant support of cochlear implant (CI) patients by CI-trained otolaryngologists and application of a standardized head bandage can minimize potential complications during magnetic resonance imaging (MRI).
Methods: Thirty-seven patients with 46 CIs underwent MRI with a prophylactic head bandage. All participants and the otolaryngologist at the CI center completed pre- and post-MRI questionnaires documenting body region scanned, duration of MRI and bandage wear, field strength during the scan, and any complications. If pain was experienced, it was assessed using a visual analog scale (1–10).
Results: MRI was performed without adverse events in 37.8% of cases. Magnet dislocation requiring surgical revision occurred in 2% of cases. Pain was reported in 86% of cases, often due to the tightness of the dressing. Patients with rotating, MRI-compatible magnets reported significantly less pain than participants with older-generation implants. In 11% of cases, the MRI was discontinued.
Conclusion: Serious complications during MRI in cochlear implant patients are rare. Pain is the most common adverse event, probably mainly due to the tight bandage required by most implant types. With newer generations of magnets, these patients experience less pain, no dislocation of the magnets, and no need for bandaging. Although magnet dislocation cannot be completely prevented in older generations of implants, it appears to be reduced by good patient management, which recommends examination under the guidance of physicians trained in the use of hearing implants.