Background: Phobic patients avoid dental treatment impairing their oral health and making it challenging to offer them prosthetic rehabilitation. This study evaluated patients’ experience of implant-supported prosthetic treatment after implantation performed under general anaesthesia due to dental phobia and severe pharyngeal reflexes (SPR). The effect of gender, age and location of implantation on patient satisfaction was tested.
Methods: Two hundred five patients underwent implantation under general anesthesia both in maxilla and mandible, respectively. After a trans-gingival healing period of 6–8 weeks, fixed implant bridges were inserted. Patients completed oral health impact profile questionnaire (OHIP-14). An additional set of six special questions was also developed and considered. Analysis of the OHIP-14 total score was made using logistics regression. Wald chi-square test was used to analyse the effect of age, gender and location of implantation. Effect sizes were estimated as odds-ratios and associated 95% Wald confidence intervals.
Results: Eighty two of 205 patients were included after prosthetic treatment. After start, 38 patients were excluded (4 died and 34 couldn’t be reached). OHIP-14-analyses were made by 43 patients (30–90 years). 67% of patients were totally satisfied with the whole implant rehabilitation (scoring 0). Mean of total score was 2.5. Only age affected significantly (p = 0.014) patients satisfaction. The obtained data indicate that younger patients (30–64 years) especially women are less satisfied (4.95) than older patients (0.3) for age group (65–90 years).Special questions’ data showed that 94.5% were satisfied with their treatment. 77.3% continued regular check-up after treatment and 96.9% would undergo the same treatment again. 95.5% would recommend implants to a friend of colleague.
Conclusion: Gender and location of implantation have no significant influence on patient satisfaction. Younger patients especially women are less satisfied than older patients. Phobic patients are totally satisfied with implant rehabilitation under general anaesthesia which means that this treatment can be considered as a treatment of choice giving these patients the same opportunity like others to improve their oral health and well-being.
he aim of this study was to evaluate the effect of controlled intraoral grinding and polishing on the roughness of full-contour zirconia compared to classical veneered zirconia. Thirty bar-shaped zirconia specimens were fabricated and divided into two groups (n=15). Fifteen specimens (group 1) were glazed and 15 specimens (group 2) were veneered with feldspathic ceramic and then glazed. Prior to grinding, maximum roughness depth (Rmax) values were measured using a profilometer, 5 times per specimen. Simulated clinical grinding and polishing were performed on the specimens under water coolant for 15 s and 2 N pressure. For grinding, NTI diamonds burs with grain sizes of 20 µm, 10 µm, and 7.5 µm were used sequentially. The ground surfaces were polished using NTI kits with coarse, medium and fine polishers. After each step, Rmax values were determined. Differences between groups were examined using one-way analysis of variance (ANOVA). The roughness of group 1 was significantly lower than that of group 2. The roughness increased significantly after coarse grinding in both groups. The results after glazing were similar to those obtained after fine grinding for non-veneered zirconia. However, fine-ground veneered zirconia had significantly higher roughness than venerred, glazed zirconia. No significant difference was found between fine-polished and glazed zirconia, but after the fine polishing of veneered zirconia, the roughness was significantly higher than after glazing. It can be concluded that for full-contour zirconia, fewer defects and lower roughness values resulted after grinding and polishing compared to veneered zirconia. After polishing zirconia, lower roughness values were achieved compared to glazing; more interesting was that the grinding of glazed zirconia using the NTI three-step system could deliver smooth surfaces comparable to untreated glazed zirconia surfaces.
The objective of this systematic review was to assess tooth wear against ceramic crowns in posterior region in vitro and in vivo. An electronic PubMed search was conducted to identify studies on tooth wear against ceramic crowns in posterior region. The selected studies were analyzed in regard to type of crowns, natural antagonist, measuring protocol and outcome. From a yield of 1 000 titles, 43 articles were selected for full-text analysis; finally, no in vitro and only five in vivo studies met the inclusion criteria. As there is heterogeneity in design, used measuring method, ceramics and analysis-form, a meta-analysis was not possible. Results of these studies are very controversial which makes a scientifically valid comparison impossible. This review indicated that some all-ceramic crowns are as wear friendly as metal-ceramic crowns. Up to now, it has been impossible to associate tooth wear with any specific causal agent. The role of ceramic surface treatment that might be responsible for the changing in rate of tooth wear seems undetermined as yet through clinical trials. The literature reveals that studies on this topic are subject to a substantial amount of bias. Therefore, additional clinical studies, properly designed to diminish bias, are warranted.