Introduction: Potential health damage by environmental emission of tobacco smoke (environmental tobacco smoke, ETS) has been demonstrated convincingly in numerous studies. People, especially children, are still exposed to ETS in the small space of private cars. Although major amounts of toxic compounds from ETS are likely transported into the distal lung via particulate matter (PM), few studies have quantified the amount of PM in ETS. Study aim The aim of this study was to determine the ETS-dependent concentration of PM from both a 3R4F reference cigarette (RC) as well as a Marlboro Red brand cigarette (MRC) in a small enclosed space under different conditions of ventilation to model car exposure.
Method: In order to create ETS reproducibly, an emitter (ETSE) was constructed and mounted on to an outdoor telephone booth with an inner volume of 1.75 m3. Cigarettes were smoked under open- and closed-door condition to imitate different ventilation scenarios. PM2.5 concentration was quantified by a laser aerosol spectrometer (Grimm; Model 1.109), and data were adjusted for baseline values. Simultaneously indoor and outdoor climate parameters were recorded. The time of smoking was divided into the ETS generation phase (subset "emission") and a declining phase of PM concentration (subset "elimination"); measurement was terminated after 10 min. For all three time periods the average concentration of PM2.5 (Cmean-PM2.5) and the area under the PM2.5 concentration curve (AUC-PM2.5) was calculated. The maximum concentration (Cmax-PM2.5) was taken from the total interval.
Results: For both cigarette types open-door ventilation reduced the AUC-PM2.5 (RC: from 59 400 +/- 14 600 to 5 550 +/- 3 900 mug*sec/m3; MRC: from 86 500 +/- 32 000 to 7 300 +/- 2 400 mug*sec/m3; p < 0.001) and Cmean-PM2.5 (RC: from 600 +/- 150 to 56 +/- 40 mug/m3, MRC from 870 +/- 320 to 75 +/- 25 mug/m3; p < 0.001) by about 90%. Cmax-PM2.5 was reduced by about 80% (RC: from 1 050 +/- 230 to 185 +/- 125 mug/m3; MRC: from 1 560 +/-500 mug/m3 to 250 +/- 85 mug/m3; p < 0.001). In the subset "emission" we identified a 78% decrease in AUC-PM2.5 (RC: from 18 600 +/- 4 600 to 4 000 +/- 2 600 mug*sec/m3; MRC: from 26 600 +/- 7 200 to 5 800 +/- 1 700 mug*sec/m3; p < 0.001) and Cmean-PM2.5 (RC: from 430 +/- 108 to 93 +/- 60 mug/m3; MRC: from 620 +/- 170 to 134 +/- 40 mug/m3; p < 0.001). In the subset "elimination" we found a reduction of about 96-98% for AUC-PM2.5 (RC: from 40 800 +/- 11 100 to 1 500 +/- 1 700 mug*sec/m3; MRC: from 58 500 +/- 25 200 to 1 400 +/- 800 mug*sec/m3; p < 0.001) and Cmean-PM2.5 (RC: from 730 +/- 200 to 27 +/- 29 mug/m3; MRC: from 1 000 +/- 450 to 26 +/- 15 mug/m3; p < 0.001). Throughout the total interval Cmax-PM2.5 of MRC was about 50% higher (1 550 +/- 500 mug/m3) compared to RC (1 050 +/- 230 mug/m3; p < 0.05). For the subset "emission" - but not for the other periods - AUC-PM2.5 for MRC was 43% higher (MRC: 26 600 +/- 7 200 mug*sec/m3; RC: 18 600 +/- 4 600 mug*sec/m3; p < 0.05) and 44% higher for Cmean-PM2.5 (MRC: 620 +/- 170 mug/m3; RC: 430 +/- 108 mug/m3; p < 0.05).
Conclusion: This method allows reliable quantification of PM2.5-ETS exposure under various conditions, and may be useful for ETS risk assessment in realistic exposure situations. The findings demonstrate that open-door condition does not completely remove ETS from a defined indoor space of 1.75 m3. Because there is no safe level of ETS exposure ventilation is not adequate enough to prevent ETS exposure in confined spaces, e.g. private cars. Additionally, differences in the characteristics of cigarettes affect the amount of ETS particle emission and need to be clarified by ongoing investigations.
Aims: Inadequate treatment is one of the factors interfering with a successful social and working life. Among students, it can impair their health and learning progress. In the field of medicine the problem of inadequate treatment seems widespread. This study examines wether inadequate treatment in internships differs between medicine and other academic disciplines.
Method: Using a questionnaire, the frequency, forms and severity of inadequate treatment among students were compared between the disciplines of medicine, civil engineering and teaching.
Results: 69,3% of medical students reported inadequate treatment during their internships, about twice as many as students of other disciplines. The ratios of verbal, non-verbal and organisational inadequate treatment were similar between the different academic disciplines. However, medical students executed tasks without receiving sufficient safety precautions or training significantly more often (sevenfold) than students of other disciplines. In total however, the experienced incidents of inadequate treatment were seen as similarly severe across the different academic fields.
Conclusion: Inadequate treatment of students during internships is a larger problem in medicine than in civil engineering or teaching, particularly concerning the performance of unsafe tasks. With regard to the health of students and patients, inadequate treatment in the medical education should be tackled. Previous studies suggest that this goal can be achieved only through longtime extensive measures on the level of students, lecturers, faculty and teaching hospitals.
Objective: Classifications of posture deviations are only possible compared with standard values. However, standard values have been published for healthy male adults but not for female adults.
Design: Observational study.
Setting: Institute of Occupational Medicine, Social Medicine and Environmental Medicine, Goethe-University Frankfurt/Main.
Participants: 106 healthy female volunteers (21–30 years old; 25.1±2.7 years) were included. Their body weight ranged from 46 to 106 kg (60.3±7.9 kg), the heights from 1.53 to 1.82 m (1.69±0.06 m) and the body mass index from 16.9 kg/m² to 37.6 kg/m² (21.1±2.6 kg/m²).
Outcome measures: A three-dimensional back scan was performed to measure the upper back posture in habitual standing. The tolerance ranges and CI were calculated. Group differences were tested by the Wilcoxon Mann-Whitney U test.
Results: In normal posture, the spinal column was marginally twisted to the left, and the vertebrae were marginally rotated to the right. The kyphosis angle is larger than the lumbar angle. Consequently, a more kyphotic posture is observed in the sagittal plane. The habitual posture is slightly scoliotic with a rotational component (scapular depression right, right scapula marginally more dorsally, high state of pelvic right, iliac right further rotated anteriorly).
Conclusions: Healthy young women have an almost ideally balanced posture with minimal ventral body inclination and a marginal scoliotic deviation. Compared with young males, women show only marginal differences in the upper body posture. These values allow a comparison to other studies, both for control and patient data, and may serve as guideline in both clinical practice and scientific studies.