Refine
Year of publication
Document Type
- Preprint (521)
- Article (288)
- Conference Proceeding (12)
- Part of a Book (5)
- Report (3)
- Working Paper (1)
Has Fulltext
- yes (830)
Is part of the Bibliography
- no (830)
Keywords
- Heavy Ion Experiments (20)
- Hadron-Hadron scattering (experiments) (11)
- Hadron-Hadron Scattering (8)
- Heavy-ion collision (5)
- Collective Flow (4)
- Quark-Gluon Plasma (4)
- Europa (3)
- Hagen <2001> (3)
- Jets (3)
- Jets and Jet Substructure (3)
- Kongress (3)
- Mehrsprachigkeit (3)
- Experimental nuclear physics (2)
- Experimental particle physics (2)
- Heavy Quark Production (2)
- Lepton-Nucleon Scattering (experiments) (2)
- Particle Correlations and Fluctuations (2)
- Particle and resonance production (2)
- Particle correlations and fluctuations (2)
- ALICE detector (1)
- Anti-nuclei (1)
- Atherosclerosis (1)
- Boosted Jets (1)
- CVID (1)
- Cardiovascular diseases (1)
- Collective Flow, (1)
- Electron-pion identification (1)
- Electroweak interaction (1)
- European Society for Immunodeficiencies (ESID) (1)
- Fibre/foam sandwich radiator (1)
- German PID-NET registry (1)
- Germany (1)
- Hadron-Hadron Scattering Heavy (1)
- Hadron-hadron interactions (1)
- Hard Scattering (1)
- Health risk analysis (1)
- Heavy Ion Experiment (1)
- IgG substitution therapy (1)
- Ionisation energy loss (1)
- Italy (1)
- Jet Physics (1)
- Jet Substructure (1)
- LHC (1)
- Material budget (1)
- Multi-Parton Interactions (1)
- Multi-wire proportional drift chamber (1)
- Myocardial infarction (1)
- Neural network (1)
- PID prevalence (1)
- Particle and Resonance Production (1)
- Pb–Pb collisions (1)
- Properties of Hadrons (1)
- Q-factor (1)
- QCD (1)
- Quark Deconfinement (1)
- Quark Gluon Plasma (1)
- Quark Production (1)
- Quarkonium (1)
- Relativistic heavy-ion collisions (1)
- Stroke (1)
- Sweden (1)
- TR (1)
- Tracking (1)
- Transition radiation detector (1)
- Trigger (1)
- Vector Boson Production (1)
- Voltri Massif (1)
- Xenon-based gas mixture (1)
- dE/dx (1)
- detector (1)
- electromagnetic field (1)
- experimental results (1)
- fluid-rock interactions (1)
- heavy ion experiments (1)
- magnesium metasomatism (1)
- measurement (1)
- primary immunodeficiency (PID) (1)
- quark gluon plasma (1)
- registry for primary immunodeficiency (1)
- subduction zones (1)
Institute
- Physik (816)
- Frankfurt Institute for Advanced Studies (FIAS) (727)
- Informatik (696)
- Neuere Philologien (10)
- Informatik und Mathematik (3)
- Geowissenschaften (2)
- Medizin (2)
- Hochschulrechenzentrum (1)
By replacing the irises in an electron linac by a slit one gets a structure capable of focussing/defocussing an electron beam (rf-quadrupoles). Therefore one can think of a combination of rf- and conventional magnetic quadrupoles for transversal focussing in linear-colliders. Furthermore they can meet the demands of BNS-damping without initial energy spread. Considering multibunch-operation of a collider, the long-range wake behaviour of this kind of structure has to be investigated. A three-cell structure has been built and investigated for dipole-type transversal long-range wakes. The experimental results are compared to numerical simulations done with MAFIA.
Mode propagation in an iris type accelerator section loaded with single heavily HOM-damped cells
(1994)
The wakefield effects in accelerator sections for future linear colliders will be reduced either by damping by detuning or by a combination of both. For the DESY/THD linac [1] it is forseen to employ heavily HOM-damped cells to provide a strong coupling to the TE/TM11-dipole passband as well as to the TM/TE11-dipole passband. For our experiments we have used wall-slotted damping cells. This leads to several problems concerning the propagation of fundamental and HOM-modes. Experimental investigations have been done. Results are presented.
To reach high luminosities in future linear colliders short range wakes havea to be controlled in the range of X-band frequencies or higher. Rectangular irises can be used to introduce strong focusing quadrupole-like rf-fields. Even circular irises in iris-loaded accelarator structures have the capability of focusing if the particle velocity differs from phase velocity. Theoretical investigations concerning the focusing strength to be expected are presented. Their applicability for linear colliders is discussed.
A new method for measuring quality factors in cavities is presented. This method is capable of measuring Q-factors in heavily damped as well as in undamped cavities. In addition, the possibility of separating overlapping modes and measuring their Q-factors is provided. Measurements on HOM (higher order mode) damped cavities for the DESY/THD linear collider project are presented
"Eurocomprehension" is the term used to describe European intercomprehension in Europe’s three major language families, the Romance, the Slavic and the Germanic. The aim of eurocomprehension is to achieve multilingualism conforming to EU language policy goals through the entry-point of receptive competence in a modular structure. Linguistic intercomprehension research forms the transfer bases for the cognitive use of relations between the language groups which didactics of multilingualism implement. ...
To preserve the required beam quality in an e+/e- collider it is necessary to have a very precise beam position control at each accelerating cavity. An elegant method to avoid additional length and beam disturbance is the usage of signals from existing HOM-dampers. The magnitude of the displacement is derived from the amplitude of a dipole mode whereas the sign follows from the phase comparison of a dipole and a monopole HOM. To check the performance of the system, a measurement setup has been built with an antenna which can be moved with micrometer resolution to simulate the beam. Furthermore we have developed a signal processing to determine the absolute beam displacement. Measurements on the HOM-damper cell can be done in the frequency domain using a network analyser. Final measurements with the nonlinear time dependent signal processing circuit has to be done with very short electric pulses simulating electron bunches. Thus, we have designed a sub nanosecond pulse generator using a clipping line and the step recovery effect of a diode. The measurement can be done with a resolution of about 10 micrometers. Measurements and numerical calculations concerning the monitor design and the pulse generator are presented.
Die Wirkungsweise des Protonen-Wendellinearbeschleunigers und sein prinzipieller Aufbau werden kurz beschrieben und Angaben über die erreichbare Parallelimpedanz gemacht. Es wird gezeigt, wie durch sektionsweisen Aufbau eine variable Endenergie erzielt und die Kühl- und Fokussierprobleme gelöst werden können. Zwei Konstruktionsbeispiele für kontinuierlichen und gepulsten Betrieb werden näher ausgeführt.
Aims: Carotid intima media thickness (CIMT) predicts cardiovascular (CVD) events, but the predictive value of CIMT change is debated. We assessed the relation between CIMT change and events in individuals at high cardiovascular risk.
Methods and results: From 31 cohorts with two CIMT scans (total n = 89070) on average 3.6 years apart and clinical follow-up, subcohorts were drawn: (A) individuals with at least 3 cardiovascular risk factors without previous CVD events, (B) individuals with carotid plaques without previous CVD events, and (C) individuals with previous CVD events. Cox regression models were fit to estimate the hazard ratio (HR) of the combined endpoint (myocardial infarction, stroke or vascular death) per standard deviation (SD) of CIMT change, adjusted for CVD risk factors. These HRs were pooled across studies.
In groups A, B and C we observed 3483, 2845 and 1165 endpoint events, respectively. Average common CIMT was 0.79mm (SD 0.16mm), and annual common CIMT change was 0.01mm (SD 0.07mm), both in group A. The pooled HR per SD of annual common CIMT change (0.02 to 0.43mm) was 0.99 (95% confidence interval: 0.95–1.02) in group A, 0.98 (0.93–1.04) in group B, and 0.95 (0.89–1.04) in group C. The HR per SD of common CIMT (average of the first and the second CIMT scan, 0.09 to 0.75mm) was 1.15 (1.07–1.23) in group A, 1.13 (1.05–1.22) in group B, and 1.12 (1.05–1.20) in group C.
Conclusions: We confirm that common CIMT is associated with future CVD events in individuals at high risk. CIMT change does not relate to future event risk in high-risk individuals.