Refine
Document Type
- Article (3)
Language
- English (3)
Has Fulltext
- yes (3)
Is part of the Bibliography
- no (3)
Keywords
- Anaemia (1)
- Mortality (1)
- Outcome (1)
- Polytrauma (1)
- Transfusion (1)
- Trauma centre (1)
- TraumaRegister DGU® (1)
Institute
- Medizin (3)
Background: The intraoperative blood loss is estimated daily in the operating room and is mainly done by visual techniques. Due to local standards, the surgical sponge colours can vary (e.g. white in US, green in Germany). The influence of sponge colour on accuracy of estimation has not been in the focus of research yet. Material and methods: A blood loss simulation study containing four “bleeding” scenarios each per sponge colour were created by using expired whole blood donation samples. The blood donations were applied to white and green surgical sponges after dilution with full electrolyte solution. Study participants had to estimate the absorbed blood loss in sponges in all scenarios. The difference to the reference blood loss was analysed. Multivariate linear regression analysis was performed to investigate other influence factors such as staff experience and sponge colour. Results: A total of 53 anaesthesists participated in the study. Visual estimation correlated moderately with reference blood loss in white (Spearman's rho: 0.521; p = 3.748*10−16) and green sponges (Spearman's rho: 0.452; p = 4.683*10−12). The median visually estimated blood loss was higher in white sponges (250ml IRQ 150–412.5ml) than in green sponges (150ml IQR 100-300ml), compared to reference blood loss (103ml IQR 86–162.8). For both colour types of sponges, major under- and overestimation was observed. The multivariate statistics demonstrates that fabric colours have a significant influence on estimation (p = 3.04*10−10), as well as clinician’s qualification level (p = 2.20*10−10, p = 1.54*10−08) and amount of RBL to be estimated (p < 2*10−16). Conclusion: The deviation of correct blood loss estimation was smaller with white surgical sponges compared to green sponges. In general, deviations were so severe for both types of sponges, that it appears to be advisable to refrain from visually estimating blood loss whenever possible and instead to use other techniques such as e.g. colorimetric estimation.
Background: Anemia is the most important complication during major surgery and transfusion of red blood cells is the mainstay to compensate for life threating blood loss. Therefore, accurate measurement of hemoglobin (Hb) concentration should be provided in real-time. Blood Gas Analysis (BGA) provides rapid point-of-care assessment using smaller sampling tubes compared to central laboratory (CL) services. Objective: This study aimed to investigate the accuracy of BGA hemoglobin testing as compared to CL services. Methods: Data of the ongoing LIBERAL-Trial (Liberal transfusion strategy to prevent mortality and anemia-associated ischemic events in elderly non-cardiac surgical patients, LIBERAL) was used to assess the bias for Hb level measured by BGA devices (ABL800 Flex analyzer®, GEM series® and RapidPoint 500®) and CL as the reference method. For that, we analyzed pairs of Hb level measured by CL and BGA within two hours. Furthermore, the impact of various confounding factors including age, gender, BMI, smoker status, transfusion of RBC, intraoperative hemodilution, and co-medication was elucidated. In order to ensure adequate statistical analysis, only data of participating centers providing more than 200 Hb pairs were used. Results: In total, three centers including 963 patients with 1,814 pairs of Hb measurements were analyzed. Mean bias was comparable between ABL800 Flex analyzer® and GEM series®: - 0.38 ± 0.15 g/dl whereas RapidPoint 500® showed a smaller bias (-0.09 g/dl) but greater median absolute deviation (± 0.45 g/dl). In order to avoid interference with different standard deviations caused by the different analytic devices, we focused on two centers using the same BGA technique (309 patients and 1,570 Hb pairs). A Bland-Altman analysis and LOWESS curve showed that bias decreased with smaller Hb values in absolute numbers but increased relatively. The smoker status showed the greatest reduction in bias (0.1 g/dl, p<0.001) whereas BMI (0.07 g/dl, p = 0.0178), RBC transfusion (0.06 g/dl, p<0.001), statins (0.04 g/dl, p<0.05) and beta blocker (0.03 g/dl, p = 0.02) showed a slight effect on bias. Intraoperative substitution of volume and other co-medications did not influence the bias significantly. Conclusion: Many interventions like substitution of fluids, coagulating factors or RBC units rely on the accuracy of laboratory measurement devices. Although BGA Hb testing showed a consistently stable difference to CL, our data confirm that BGA devices are associated with different bias. Therefore, we suggest that hospitals assess their individual bias before implementing BGA as valid and stable supplement to CL. However, based on the finding that bias decreased with smaller Hb values, which in turn are used for transfusion decision, we expect no unnecessary or delayed RBC transfusion, and no major impact on the LIBERAL trial performance.
Purpose: Anaemia is one of the leading causes of death among severely injured patients. It is also known to increase the risk of death and prolong the length of hospital stay in various surgical groups. The main objective of this study is to analyse the anaemia rate on admission to the emergency department and the impact of anaemia on in-hospital mortality.
Methods: Data from the TraumaRegister DGU® (TR-DGU) between 2015 and 2019 were analysed. Inclusion criteria were age ≥ 16 years and most severe Abbreviated Injury Scale (AIS) score ≥ 3. Patients were divided into three anaemia subgroups: no or mild anaemia (NA), moderate anaemia (MA) and severe anaemia (SA). Pre-hospital data, patient characteristics, treatment in the emergency room (ER), outcomes, and differences between trauma centres were analysed.
Results: Of 67,595 patients analysed, 94.9% (n = 64,153) exhibited no or mild anaemia (Hb ≥ 9 g/dl), 3.7% (n = 2478) displayed moderate anaemia (Hb 7–8 g/dl) and 1.4% (n = 964) presented with severe anaemia (Hb < 7 g/dl). Haemoglobin (Hb) values ranged from 3 to 18 g/dl with a mean Hb value of 12.7 g/dl. In surviving patients, anaemia was associated with prolonged length of stay (LOS). Multivariate logistic regression analyses revealed moderate (p < 0.001 OR 1.88 (1.66–2.13)) and severe anaemia (p < 0.001 OR 4.21 (3.46–5.12)) to be an independent predictor for mortality. Further significant predictors are ISS score per point (OR 1.0), age 70–79 (OR 4.8), age > 80 (OR 12.0), severe pre-existing conditions (ASA 3/4) (OR 2.26), severe head injury (AIS 5/6) (OR 4.8), penetrating trauma (OR 1.8), unconsciousness (OR 4.8), shock (OR 2.2) and pre-hospital intubation (OR 1.6).
Conclusion: The majority of severely injured patients are admitted without anaemia to the ER. Injury-associated moderate and severe anaemia is an independent predictor of mortality in severely injured patients.