Refine
Year of publication
Document Type
- Article (28)
- Doctoral Thesis (1)
- Working Paper (1)
Has Fulltext
- yes (30)
Is part of the Bibliography
- no (30)
Keywords
- Musculoskeletal system (3)
- ergonomics (3)
- inertial motion capture (3)
- Healthy adults (2)
- Knees (2)
- kinematic analysis (2)
- musculoskeletal disorders (2)
- ACLF (1)
- AD patients (1)
- Anatomy (1)
Institute
Background: Temporary occlusal changes and their influence on the upper body statics are still controversially discussed. Furthermore, concrete statements on whether age- or gender-specific differences in neurophysiological reactions exist are missing. Therefore, it is the aim of this study to evaluate the immediate effects of a symmetrical occlusion blocking on the upper body posture. These effects shall be investigated for both genders and for a larger age range.
Methods: In this study, 800 (407f/393 m) subjects volunteered aged from 21 to 60 years. Both genders were divided into four age groups according to decades. The three-dimensional upper body posture was measured by using the rasterstereography (ABW-Bodymapper). The habitual static posture was measured in two dental occlusion conditions (a) in rest position and (b) symmetrical blocking in the bicuspid region by cotton rolls.
Results: A significant reduction of the trunk length (0.72 mm; p < 0.001), an increase of the lumbar (0.30°; p < 0.001) and the thoracic bending angle (0.14°; p = 0.001), a reduction of the spinal forward decline (0.16°; p < 0.001) and a reduction of the scapular distance (0.36 mm; p = 0.001) was found. Gender-specific reactions can only be recorded in scapular distance, in that regard men reduce this distance while over all age groups women did not show a significant change.
Discussion: Slight gender- and age-independent reactions due to a symmetric occlusion blockade are shown: A gender independent reaction of the spinal related variables in the sagittal plane (thoracic and lumbar flexion angle, trunk length, spinal forward decline). In addition, a gender specific change of the shoulder blade distance could be observed, where men reduced the distance while female did not show a change. However, since these reactions are of a minimum amount, it can be concluded that neurophysiological compensation mechanisms work equally well regardless of age and sex, and the upper body posture of healthy people changes only very slightly due to a temporarily symmetrical altered bite position.
Objectives: Symmetrical dental occlusion blocking is used in dentistry as a quick diagnostic tool to test for potential influences of the craniomandibular system on body sway and weight distribution. This study presents the changes of body sway and pressure distribution in healthy subjects, free of a temporomandibular dysfunction (TMD). Immediate effects between occlusal blocking and rest position on body sway and body weight distribution in general, as well as for both genders and for four age decades will be evaluated.
Materials and methods: 725 (396f/329 m) subjects (neither subjective signs of TMD nor acute/chronic complaints in the musculoskeletal system) volunteered (21 to 60 years) while both genders were divided into four age groups according to decades. A pressure measuring platform was used. Body sway and weight distribution were recorded in two dental occlusion conditions (a) in rest position and (b) symmetrical blocking (bicuspid region) by cotton rolls.
Results: Both, the frontal sway and the sagittal sway reduced by 0.67 mm (t(724) = − 3.9 (p < 0.001)) and by 0.33 mm (t(724) = − 3.4 (p < 0.001)). The relative pressure under the left forefoot increased by 0.33% (t(724) = 2.88 (p < 0.001)) and the relative pressure overall under the forefoot increased by 0.67% (t(724) = − 3.4 (p < 0.001)). Gender-specific, age-specific and BMI-specific reactions could not be identified.
Conclusions: Subjects, free of any TMD and with no complaints of the musculoskeletal system, show small changes of the body sway and weight distribution when biting symmetrically on a cotton roll. These changes are independent of age, gender or body mass index (BMI). Due to the relative large sample size, the presented results can also be seen as norm values when body sway is used as an additional assessment of a TMD.
Musculoskeletal disorders of the trunk and neck are common among cleaners. Vacuum cleaning is a demanding activity. The aim of this study was to present the movement profile of the trunk and neck during habitual vacuuming. The data were collected from 31 subjects (21f./10 m) using a 3D motion analysis system (Xsens). 10 cycles were analysed in vacuuming PVC and carpet floors with 8 vacuum cleaners. The joint angles and velocities were represented statistically descriptive. When vacuuming, the trunk is held in a forwardly inclined position by a flexion in the hip and rotated from this position. In the joint angles and velocities of the spine, the rotation proved to be dominant. A relatively large amount of movement took place in the cervical spine and also in the lumbar spine. The shown movement profile is rather a comfort area of vacuuming which may serve as a reference for ergonomics in vacuuming.
Background: In general, the prevalence of work-related musculoskeletal disorders (WMSD) in dentistry is high, and dental assistants (DA) are even more affected than dentists (D). Furthermore, differentiations between the fields of dental specialization (e.g., general dentistry, endodontology, oral and maxillofacial surgery, or orthodontics) are rare. Therefore, this study aims to investigate the ergonomic risk of the aforementioned four fields of dental specialization for D and DA on the one hand, and to compare the ergonomic risk of D and DA within each individual field of dental specialization. Methods: In total, 60 dentists (33 male/27 female) and 60 dental assistants (11 male/49 female) volunteered in this study. The sample was composed of 15 dentists and 15 dental assistants from each of the dental field, in order to represent the fields of dental specialization. In a laboratory setting, all tasks were recorded using an inertial motion capture system. The kinematic data were applied to an automated version of the Rapid Upper Limb Assessment (RULA). Results: The results revealed significantly reduced ergonomic risks in endodontology and orthodontics compared to oral and maxillofacial surgery and general dentistry in DAs, while orthodontics showed a significantly reduced ergonomic risk compared to general dentistry in Ds. Further differences between the fields of dental specialization were found in the right wrist, right lower arm, and left lower arm in DAs and in the neck, right wrist, right lower arm, and left wrist in Ds. The differences between Ds and DAs within a specialist discipline were rather small. Discussion: Independent of whether one works as a D or DA, the percentage of time spent working in higher risk scores is reduced in endodontologists, and especially in orthodontics, compared to general dentists or oral and maxillofacial surgeons. In order to counteract the development of WMSD, early intervention should be made. Consequently, ergonomic training or strength training is recommended.
In the application of range of motion (ROM) tests there is little agreement on the number of repetitions to be measured and the number of preceding warm-up protocols. In stretch training a plateau in ROM gains can be seen after four to five repetitions. With increasing number of repetitions, the gain in ROM is reduced. This study examines the question of whether such an effect occurs in common ROM tests. Twenty-two healthy sport students (10 m/12 f.) with an average age of 25.3 ± 1.94 years (average height 174.1 ± 9.8 cm; weight 66.6 ± 11.3 kg and BMI 21.9 ± 2.0 kg/cm2) volunteered in this study. Each subject performed five ROM tests in a randomized order—measured either via a tape measure or a digital inclinometer: Tape measure was used to evaluate the Fingertip-to-Floor test (FtF) and the Lateral Inclination test (LI). Retroflexion of the trunk modified after Janda (RF), Thomas test (TT) and a Shoulder test modified after Janda (ST) were evaluated with a digital inclinometer. In order to show general acute effects within 20 repetitions we performed ANOVA/Friedman-test with multiple comparisons. A non-linear regression was then performed to identify a plateau formation. Significance level was set at 5%. In seven out of eight ROM tests (five tests in total with three tests measured both left and right sides) significant flexibility gains were observed (FtF: p < 0.001; LI-left/right: p < 0.001/0.001; RF: p = 0.009; ST-left/right: p < 0.001/p = 0.003; TT-left: p < 0.001). A non-linear regression with random effects was successfully applied on FtF, RF, LI-left/right, ST-left and TT-left and thus, indicate a gradual decline in the amount of gained ROM. An acute effect was observed in most ROM tests, which is characterized by a gradual decline of ROM gain. For those tests, we can state that the acute effect described in the stretching literature also applies to the performance of typical ROM tests. Since a non-linear behavior was shown, it is the decision of the practitioner to weigh up between measurement accuracy and expenditure. Researchers and practitioners should consider this when applying ROM assessments to healthy young adults.
Background: In clinical practice range of motion (RoM) is usually assessed with low-cost devices such as a tape measure (TM) or a digital inclinometer (DI). However, the intra- and inter-rater reliability of typical RoM tests differ, which impairs the evaluation of therapy progress. More objective and reliable kinematic data can be obtained with the inertial motion capture system (IMC) by Xsens. The aim of this study was to obtain the intra- and inter-rater reliability of the TM, DI and IMC methods in five RoM tests: modified Thomas test (DI), shoulder test modified after Janda (DI), retroflexion of the trunk modified after Janda (DI), lateral inclination (TM) and fingertip-to-floor test (TM).
Methods: Two raters executed the RoM tests (TM or DI) in a randomized order on 22 healthy individuals while, simultaneously, the IMC data (Xsens MVN) was collected. After 15 warm-up repetitions, each rater recorded five measurements.
Findings: Intra-rater reliabilities were (almost) perfect for tests in all three devices (ICCs 0.886–0.996). Inter-rater reliability was substantial to (almost) perfect in the DI (ICCs 0.71–0.87) and the IMC methods (ICCs 0.61–0.993) and (almost) perfect in the TM methods (ICCs 0.923–0.961). The measurement error (ME) for the tests measured in degree (°) was 0.9–3.3° for the DI methods and 0.5–1.2° for the IMC approaches. In the tests measured in centimeters the ME was 0.5–1.3cm for the TM methods and 0.6–2.7cm for the IMC methods. Pearson correlations between the results of the DI or the TM respectively with the IMC results were significant in all tests except for the shoulder test on the right body side (r = 0.41–0.81).
Interpretation: Measurement repetitions of either one or multiple trained raters can be considered reliable in all three devices.
Purpose: Perfusion-weighted MRI (PWI) and O-(2-[18F]fluoroethyl-)-l-tyrosine ([18F]FET) PET are both applied to discriminate tumor progression (TP) from treatment-related changes (TRC) in patients with suspected recurrent glioma. While the combination of both methods has been reported to improve the diagnostic accuracy, the performance of a sequential implementation has not been further investigated. Therefore, we retrospectively analyzed the diagnostic value of consecutive PWI and [18F]FET PET.
Methods: We evaluated 104 patients with WHO grade II–IV glioma and suspected TP on conventional MRI using PWI and dynamic [18F]FET PET. Leakage corrected maximum relative cerebral blood volumes (rCBVmax) were obtained from dynamic susceptibility contrast PWI. Furthermore, we calculated static (i.e., maximum tumor to brain ratios; TBRmax) and dynamic [18F]FET PET parameters (i.e., Slope). Definitive diagnoses were based on histopathology (n = 42) or clinico-radiological follow-up (n = 62). The diagnostic performance of PWI and [18F]FET PET parameters to differentiate TP from TRC was evaluated by analyzing receiver operating characteristic and area under the curve (AUC).
Results: Across all patients, the differentiation of TP from TRC using rCBVmax or [18F]FET PET parameters was moderate (AUC = 0.69–0.75; p < 0.01). A rCBVmax cutoff > 2.85 had a positive predictive value for TP of 100%, enabling a correct TP diagnosis in 44 patients. In the remaining 60 patients, combined static and dynamic [18F]FET PET parameters (TBRmax, Slope) correctly discriminated TP and TRC in a significant 78% of patients, increasing the overall accuracy to 87%. A subgroup analysis of isocitrate dehydrogenase (IDH) mutant tumors indicated a superior performance of PWI to [18F]FET PET (AUC = 0.8/< 0.62, p < 0.01/≥ 0.3).
Conclusion: While marked hyperperfusion on PWI indicated TP, [18F]FET PET proved beneficial to discriminate TP from TRC when PWI remained inconclusive. Thus, our results highlight the clinical value of sequential use of PWI and [18F]FET PET, allowing an economical use of diagnostic methods. The impact of an IDH mutation needs further investigation.
Objective: The influence of the jaw position on postural control, body posture, walking and running pattern has been reported in the literature. All these movements have in common that a relatively small, but well controlled muscle activation is required. The induced effects on motor output through changed jaw positions have been small. Therefore, it has been questioned if it could still be observed in maximal muscle activation.
Method: Twenty-three healthy, mid age recreational runners (mean age = 34.0 ± 10.3 years) participated in this study. Three different jump tests (squat jump, counter movement jump, and drop jumps from four different heights) and three maximal strength tests (trunk flexion and extension, leg press of the right and left leg) were conducted. Four different dental occlusion conditions and an additional familiarization condition were tested. Subjects performed the tests on different days for which the four occlusion conditions were randomly changed.
Results: No familiarization effect was found. Occlusion conditions with a relaxation position and with a myocentric condylar position showed significantly higher values for several tests compared to the neutral condition and the maximal occlusion position. Significance was found in the squat jump, countermovement jump, the drop jump from 32cm and 40cm, trunk extension, leg press force and rate of force development. The effect due to the splint conditions is an improvement between 3% and 12% (min and max). No influence of the jaw position on symmetry or balance between extension and flexion muscle was found.
Conclusion: An influence of occlusion splints on rate of force development (RFD) and maximal strength tests could be confirmed. A small, but consistent increase in the performance parameters could be measured. The influence of the occlusion condition is most likely small compared to other influences as for example training status, age, gender and circadian rhythm.
Introduction: The effects of manipulated dental occlusion on body posture has been investigated quite often and discussed controversially in the literature. Far less attention has been paid to the influence of dental occlusion position on human movement. If human movement was analysed, it was mostly while walking and not while running. This study was therefore designed to identify the effect of lower jaw positions on running behaviour according to different dental occlusion positions.
Methods: Twenty healthy young recreational runners (mean age = 33.9±5.8 years) participated in this study. Kinematic data were collected using an eight-camera Vicon motion capture system (VICON Motion Systems, Oxford, UK). Subjects were consecutively prepared with four different dental occlusion conditions in random order and performed five running trials per test condition on a level walkway with their preferred running shoes. Vector based pattern recognition methods, in particular cluster analysis and support vector machines (SVM) were used for movement pattern identification.
Results: Subjects exhibited unique movement patterns leading to 18 clusters for the 20 subjects. No overall classification of the splint condition could be observed. Within individual subjects different running patterns could be identified for the four splint conditions. The splint conditions lead to a more symmetrical running pattern than the control condition.
Discussion: The influence of an occlusal splint on running pattern can be confirmed in this study. Wearing a splint increases the symmetry of the running pattern. A more symmetrical running pattern might help to reduce the risk of injuries or help in performance. The change of the movement pattern between the neutral condition and any of the three splint conditions was significant within subjects but not across subjects. Therefore the dental splint has a measureable influence on the running pattern of subjects, however subjects individuality has to be considered when choosing the optimal splint condition for a specific subject.
Introduction: Musicians often perform in forced postures over a long period of time, which in the worst case may lead to playing-related musculoskeletal disorders. In this context, the ergonomics of the musician's chair (construction and surface quality) can be an influencing factor, with impact on the seating position of the upper body and the pressure distribution of the bottom. Therefore, the relationship between different musician chairs and musicians of different playing levels (professional, amateur or student) was analyzed in order to gain useful insights whether playing experience, playing level, playing style (symmetrical or asymmetrical) or gender have an impact.
Method: The total dataset of 47 musicians (3 playing levels: professional, amateur, student) were analysed on six musician chairs with different ergonomic layout. Sitting on each chair without instrument (condition 1) and with instrument (condition 2), the upper body posture (videorasterstereography) and the seat pressure (load distribution) were recorded.as Also, a subjective assessment concerning constitutional data, sitting behaviour, prevailing pain in the musculoskeletal system, sport activity and chair comfort rating, was completed using a questionnaire.
Results: There were significant differences shown in 6 of 17 variables, where all between and within factors were accounted for with a MANOVA. Two measurements of the upper body posture (scapular distance and scapular height) differentiated between playing level. Four of the pressure measurements (pressure under the sit bone and the thigh for the left and the right side) differentiated between chairs and the two conditions (with and without instrument). Chairs with soft cushioning had a mean pressure reduction of about 30%. The pressure was increased by about 10% while playing an instrument. Subjective rating was correlated to age for some of the chairs.
Discussion: Differences between chairs are mainly associated with the pressure distribution under the sitting surface. Playing with an instrument puts an additional force onto the surface of the chair that is more than the weight of the instrument. No relationship between pressure data and upper body posture data could be found. Therefore, it can be speculated that the intersubject variability is larger than systematic differences introduced by the chair or instrument.