Refine
Year of publication
Document Type
- Article (37)
- Conference Proceeding (1)
Language
- English (38)
Has Fulltext
- yes (38)
Is part of the Bibliography
- no (38)
Keywords
- ARDS (1)
- Accelerators & Beams (1)
- Accelerators & storage rings (1)
- Activation (1)
- Atomic & molecular beams (1)
- Atomic, Molecular & Optical (1)
- Beam loss (1)
- Beta decay (1)
- Biomarkers (1)
- COVID-19 (1)
Institute
Background: Peritonitis is responsible for thousands of deaths annually in Germany alone. Even source control (SC) and antibiotic treatment often fail to prevent severe sepsis or septic shock, and this situation has hardly improved in the past two decades. Most experimental immunomodulatory therapeutics for sepsis have been aimed at blocking or dampening a specific pro-inflammatory immunological mediator. However, the patient collective is large and heterogeneous. There are therefore grounds for investigating the possibility of developing personalized therapies by classifying patients into groups according to biomarkers. This study aims to combine an assessment of the efficacy of treatment with a preparation of human immunoglobulins G, A, and M (IgGAM) with individual status of various biomarkers (immunoglobulin level, procalcitonin, interleukin 6, antigen D-related human leucocyte antigen (HLA-DR), transcription factor NF-κB1, adrenomedullin, and pathogen spectrum).
Methods/design: A total of 200 patients with sepsis or septic shock will receive standard-of-care treatment (SoC). Of these, 133 patients (selected by 1:2 randomization) will in addition receive infusions of IgGAM for 5 days. All patients will be followed for approximately 90 days and assessed by the multiple-organ failure (MOF) score, by the EQ QLQ 5D quality-of-life scale, and by measurement of vital signs, biomarkers (as above), and survival.
Discussion: This study is intended to provide further information on the efficacy and safety of treatment with IgGAM and to offer the possibility of correlating these with the biomarkers to be studied. Specifically, it will test (at a descriptive level) the hypothesis that patients receiving IgGAM who have higher inflammation status (IL-6) and poorer immune status (low HLA-DR, low immunoglobulin levels) have a better outcome than patients who do not receive IgGAM. It is expected to provide information that will help to close the knowledge gap concerning the association between the effect of IgGAM and the presence of various biomarkers, thus possibly opening the way to a personalized medicine.
Trial registration: EudraCT, 2016–001788-34; ClinicalTrials.gov, NCT03334006. Registered on 17 Nov 2017.
Trial sponsor: RWTH Aachen University, represented by the Center for Translational & Clinical Research Aachen (contact Dr. S. Isfort).
Neutron total cross sections are an important source of experimental data in the evaluation of neutron-induced cross sections. The sum of all neutron-induced reaction cross sections can be determined with a precision of a few per cent in a relative measurement. The neutron spectrum of the photoneutron source nELBE extends in the fast region from about 100 keV to 10 MeV and has favourable conditions for transmission measurements due to the low instantaneous flux of neutrons and low gamma-flash background. Several materials of interest (in part included in the CIELO evaluation or on the HPRL of OECD/NEA) have been investigated: 197Au [1, 2], natFe [2], natW [2], 238U, natPt, 4He, natO, natNe, natXe. For gaseous targets high pressure gas cells with flat end-caps have been built that hold up to 200 bar pressure. The experimental setup will be presented including results from several transmission experiments and the data analysis leading to the total cross sections will be discussed.
Background: Asthma is increasing worldwide and results from a complex immunological interaction between genetic susceptibility and environmental factors. Autovaccination with E. coli induces a strong TH-1 immune response, thus offering an option for the treatment of allergic diseases. Methods: Prospective open trial on safety, tolerability, and impact on allergic inflammation of an autologous E.coli autovaccine in intermittent or mild persistent house dust mite asthma. Determination of exhaled nitric monoxide (eNO) before and after bronchial mite challenge initially and after nine months of autovaccination. Results: Median eNO increase after autovaccination was significantly smaller (from 27.3 to 33.8 ppb; p=0.334) compared to initial values (from 32.6 to 42.2 ppb; p=0.046) (p=0.034). In nine subjects and a total of 306 injections, we observed 101 episodes of local erythema (33.3%; median of maximal diameter 2.5 cm), 95 episodes of local swelling (31.1%; median of maximal diameter 3 cm), and 27 episodes of local pain (8.8%). Four subjects reported itching at the injection site with a total of 30 episodes (9.8%). We observed no serious adverse events. All organ functions (inclusive electrocardiogramm) and laboratory testing of the blood (clinical chemistry, hematology) and the urine (screening test, B-microglobuline) were within normal limits. Vital signs undulated within the physiological variability. Conclusion: The administration of autologous autovacine for the treatment of house dust mite asthma resulted in a reduction of the eNO increase upon bronchial mite challenge. In nine subjects and 306 injections, only a few mild local reactions and no systemic severe adverse events were observed. EudraCT Nr. 2005-005534-12 ClinicalTrials.gov ID NCT00677209
Activations with neutrons in the keV energy range were routinely performed at the Karlsruhe Institute of Technology (KIT) in Germany in order to simulate stellar conditions for neutron-capture cross sections. A quasi-Maxwell-Boltzmann neutron spectrum of kT = 25 keV, being of interest for the astrophysical s-process, was produced by the 7Li(p,n) reaction utilizing a 1912 keV proton beam at the Karlsruhe Van de Graaff accelerator. Activated samples resulting in long-lived nuclear reaction products with half-lives in the order of yr 100 Myr were analyzed by Accelerator Mass Spectrometry (AMS). Comparison of the obtained reaction cross sections to literature data from previous Time-of-Flight (ToF) measurements showed that the selected AMS data are systematically lower than the ToF data. To investigate this discrepancy, 54Fe(n,γ)55Fe and 35Cl(n,γ)36Cl reaction cross sections were newly measured at the Frankfurt Neutron Source (FRANZ) in Germany. To complement the existing data, an additional neutron activation of 54Fe and 35Cl at a proton energy of 2 MeV was performed. The results will give implications for the stellar environment at kT = 90 keV, reaching the not yet experimentally explored high-energy s-process range. AMS measurements of the activated samples are scheduled.
About 50% of the elements heavier than iron are produced during the slow neutron capture process. This process occurs in different stellar sites at various energies. To understand the ongoing nucleosynthesis, the probability of a neutron capture for different temperatures and therefore for different stellar sites is essential. Activation experiments using the 7Li(p,n) reaction as neutron source were performed. At a temperature of kBT = 25 keV the cross sections were determined for 27Al, 37Cl and 41K. A new method was developed to perform activation experiments at even lower temperatures. For a proof of principle, the cross section for 64Ni was measured at kBT = 25 keV as well as for kBT = 6 keV. To study the impact of isomeric states at higher energies, activations of 181Ta were performed using two different proton energies.
The study of neutron-induced reactions is of high relevance in a wide variety of fields, ranging from stellar nucleosynthesis and fundamental nuclear physics to applications of nuclear technology. In nuclear energy, high accuracy neutron data are needed for the development of Generation IV fast reactors and accelerator driven systems, these last aimed specifically at nuclear waste incineration, as well as for research on innovative fuel cycles. In this context, a high luminosity Neutron Time Of Flight facility, n_TOF, is operating at CERN since more than a decade, with the aim of providing new, high accuracy and high resolution neutron cross-sections. Thanks to the features of the neutron beam, a rich experimental program relevant to nuclear technology has been carried out so far. The program will be further expanded in the near future, thanks in particular to a new high-flux experimental area, now under construction.
High precision measurement of the radiative capture cross section of 238U at the n_TOF CERN facility
(2017)
The importance of improving the accuracy on the capture cross-section of 238U has been addressed by the Nuclear Energy Agency, since its uncertainty significantly affects the uncertainties of key design parameters for both fast and thermal nuclear reactors. Within the 7th framework programme ANDES of the European Commission three different measurements have been carried out with the aim of providing the 238U(n,γ) cross-section with an accuracy which varies from 1 to 5%, depending on the energy range. Hereby the final results of the measurement performed at the n_TOF CERN facility in a wide energy range from 1 eV to 700 keV will be presented.
Neutron-induced fission cross sections of 238U and 235U are used as standards in the fast neutron region up to 200 MeV. A high accuracy of the standards is relevant to experimentally determine other neutron reaction cross sections. Therefore, the detection effciency should be corrected by using the angular distribution of the fission fragments (FFAD), which are barely known above 20 MeV. In addition, the angular distribution of the fragments produced in the fission of highly excited and deformed nuclei is an important observable to investigate the nuclear fission process.
In order to measure the FFAD of neutron-induced reactions, a fission detection setup based on parallel-plate avalanche counters (PPACs) has been developed and successfully used at the CERN-n_TOF facility. In this work, we present the preliminary results on the analysis of new 235U(n,f) and 238U(n,f) data in the extended energy range up to 200 MeV compared to the existing experimental data.
The n_TOF facility operates at CERN with the aim of addressing the request of high accuracy nuclear data for advanced nuclear energy systems as well as for nuclear astrophysics. Thanks to the features of the neutron beam, important results have been obtained on neutron induced fission and capture cross sections of U, Pu and minor actinides. Recently the construction of another beam line has started; the new line will be complementary to the first one, allowing to further extend the experimental program foreseen for next measurement campaigns.
The aim of this work is to provide a precise and accurate measurement of the 238U(n,γ) reaction cross section in the energy region from 1 eV to 700 keV. This reaction is of fundamental importance for the design calculations of nuclear reactors, governing the behavior of the reactor core. In particular, fast reactors, which are experiencing a growing interest for their ability to burn radioactive waste, operate in the high energy region of the neutron spectrum. In this energy region most recent evaluations disagree due to inconsistencies in the existing measurements of up to 15%. In addition, the assessment of nuclear data uncertainty performed for innovative reactor systems shows that the uncertainty in the radiative capture cross section of 238U should be further reduced to 1–3% in the energy region from 20 eV to 25 keV. To this purpose, addressed by the Nuclear Energy Agency as a priority nuclear data need, complementary experiments, one at the GELINA and two at the n_TOF facility, were proposed and carried out within the 7th Framework Project ANDES of the European Commission. The results of one of these 238U(n,γ) measurements performed at the n_TOF CERN facility are presented in this work. The γ-ray cascade following the radiative neutron capture has been detected exploiting a setup of two C6D6 liquid scintillators. Resonance parameters obtained from this work are on average in excellent agreement with the ones reported in evaluated libraries. In the unresolved resonance region, this work yields a cross section in agreement with evaluated libraries up to 80 keV, while for higher energies our results are significantly higher.