Institute
- Medizin (2)
Background: Cerebral O2 saturation (ScO2) reflects cerebral perfusion and can be measured noninvasively by near-infrared spectroscopy (NIRS). Objectives: In this pilot study, we describe the dynamics of ScO2 during TAVI in nonventilated patients and its impact on procedural outcome. Methods and Results: We measured ScO2 of both frontal lobes continuously by NIRS in 50 consecutive analgo-sedated patients undergoing transfemoral TAVI (female 58%, mean age 80.8 years). Compared to baseline ScO2 dropped significantly during RVP (59.3% vs. 53.9%, p < .01). Five minutes after RVP ScO2 values normalized (post RVP 62.6% vs. 53.9% during RVP, p < .01; pre 61.6% vs. post RVP 62.6%, p = .53). Patients with an intraprocedural pathological ScO2 decline of >20% (n = 13) had higher EuroSCORE II (3.42% vs. 5.7%, p = .020) and experienced more often delirium (24% vs. 62%, p = .015) and stroke (0% vs. 23%, p < .01) after TAVI. Multivariable logistic regression revealed higher age and large ScO2 drops as independent risk factors for delirium. Conclusions: During RVP ScO2 significantly declined compared to baseline. A ScO2 decline of >20% is associated with a higher incidence of delirium and stroke and a valid cut-off value to screen for these complications. NIRS measurement during TAVI procedure may be an easy to implement diagnostic tool to detect patients at high risks for cerebrovascular complications and delirium.
Background: Cerebral oxygen saturation (ScO2) can be measured non-invasively by near-infrared spectroscopy (NIRS) and correlates with cerebral perfusion. We investigated cerebral saturation during transfemoral transcatheter aortic valve implantation (TAVI) and its impact on outcome.
Methods and results: Cerebral oxygenation was measured continuously by NIRS in 173 analgo-sedated patients during transfemoral TAVI (female 47%, mean age 81 years) with self-expanding (39%) and balloon-expanding valves (61%). We investigated the periprocedural dynamics of cerebral oxygenation. Mean ScO2 at baseline without oxygen supply was 60%. During rapid ventricular pacing, ScO2 dropped significantly (before 64% vs. after 55%, p < 0.001). ScO2 at baseline correlated positively with baseline left-ventricular ejection fraction (0.230, p < 0.006) and hemoglobin (0.327, p < 0.001), and inversely with EuroSCORE-II ( − 0.285, p < 0.001) and length of in-hospital stay ( − 0.229, p < 0.01). Patients with ScO2 < 56% despite oxygen supply at baseline had impaired 1 year survival (log-rank test p < 0.01) and prolonged in-hospital stay (p = 0.03). Furthermore, baseline ScO2 was found to be a predictor for 1 year survival independent of age and sex (multivariable adjusted Cox regression, p = 0.020, hazard ratio (HR 0.94, 95% CI 0.90–0.99) and independent of overall perioperative risk estimated by EuroSCORE-II and hemoglobin (p = 0.03, HR 0.95, 95% CI 0.91–0.99).
Conclusions: Low baseline ScO2 not responding to oxygen supply might act as a surrogate for impaired cardiopulmonary function and is associated with worse 1 year survival and prolonged in-hospital stay after transfemoral TAVI. ScO2 monitoring is an easy to implement diagnostic tool to screen patients at risk with a potential preserved recovery and worse outcome after TAVI.