Refine
Document Type
- Article (6)
Has Fulltext
- yes (6)
Is part of the Bibliography
- no (6)
Keywords
- Europe (1)
- perinatal HIV infection (1)
- virological failure (1)
- young people (1)
Institute
- Medizin (4)
Gemas Artikel 11 der FFH-Richtlinie ist ein Monitoring des Erhaltungszustandes der Arten von gemeinschaftlicher Bedeutung durchzufuhren. Weiterhin ist nach Artikel 12 eine fortlaufende Überwachung des unbeabsichtigten Fangs oder Tötens der Anhang IV-Tierarten vorgeschrieben, worauf gegebenenfalls weiterführende Erhaltungsmaßnahmen und Forschung aufbauen sollen. Im § 40 BNatSchG wird dieses Monitoring in die Verantwortung der Bundesländer übergeben.
Background Osseointegration is crucial for the long-term success of dental implants and depends on the tissue reaction at the tissue-implant interface. Mechanical properties and biocompatibility make zirconia a suitable material for dental implants, although surface processings are still problematic. The aim of the present study was to compare osteoblast behavior on structured zirconia and titanium surfaces under standardized conditions. Methods The surface characteristics were determined by scanning electron microscopy (SEM). In primary bovine osteoblasts attachment kinetics, proliferation rate and synthesis of bone-associated proteins were tested on different surfaces. Results The results demonstrated that the proliferation rate of cells was significantly higher on zirconia surfaces than on titanium surfaces (p < 0.05; Student's t-test). In contrast, attachment and adhesion strength of the primary cells was significant higher on titanium surfaces (p < 0.05; U test). No significant differences were found in the synthesis of bone-specific proteins. Ultrastructural analysis revealed phenotypic features of osteoblast-like cells on both zirconia and titanium surfaces. Conclusion The study demonstrates distinct effects of the surface composition on osteoblasts in culture. Zirconia improves cell proliferation significantly during the first days of culture, but it does not improve attachment and adhesion strength. Both materials do not differ with respect to protein synthesis or ultrastructural appearance of osteoblasts. Zirconium oxide may therefore be a suitable material for dental implants.
Background Titanium and titanium alloys are widely used for fabrication of dental implants. Since the material composition and the surface topography of a biomaterial play a fundamental role in osseointegration, various chemical and physical surface modifications have been developed to improve osseous healing. Zirconia-based implants were introduced into dental implantology as an altenative to titanium implants. Zirconia seems to be a suitable implant material because of its tooth-like colour, its mechanical properties and its biocompatibility. As the osseointegration of zirconia implants has not been extensively investigated, the aim of this study was to compare the osseous healing of zirconia implants with titanium implants which have a roughened surface but otherwise similar implant geometries. Methods Forty-eight zirconia and titanium implants were introduced into the tibia of 12 minipigs. After 1, 4 or 12 weeks, animals were sacrificed and specimens containing the implants were examined in terms of histological and ultrastructural techniques. Results Histological results showed direct bone contact on the zirconia and titanium surfaces. Bone implant contact as measured by histomorphometry was slightly better on titanium than on zirconia surfaces. However, a statistically significant difference between the two groups was not observed. Conclusion The results demonstrated that zirconia implants with modified surfaces result in an osseointegration which is comparable with that of titanium implants.
Background The successful use of zirconia ceramics in orthopedic surgery led to a demand for dental zirconium-based implant systems. Because of its excellent biomechanical characteristics, biocompatibility, and bright tooth-like color, zirconia (zirconium dioxide, ZrO2) has the potential to become a substitute for titanium as dental implant material. The present study aimed at investigating the osseointegration of zirconia implants with modified ablative surface at an ultrastructural level. Methods A total of 24 zirconia implants with modified ablative surfaces and 24 titanium implants all of similar shape and surface structure were inserted into the tibia of 12 Gottinger minipigs. Block biopsies were harvested 1 week, 4 weeks or 12 weeks (four animals each) after surgery. Scanning electron microscopy (SEM) analysis was performed at the bone implant interface. Results Remarkable bone attachment was already seen after 1 week which increased further to intimate bone contact after 4 weeks, observed on both zirconia and titanium implant surfaces. After 12 weeks, osseointegration without interposition of an interfacial layer was detected. At the ultrastructural level, there was no obvious difference between the osseointegration of zirconia implants with modified ablative surfaces and titanium implants with a similar surface topography. Conclusion The results of this study indicate similar osseointegration of zirconia and titanium implants at the ultrastructural level.
Schriftenschau
(2011)
Objectives: The aim of the study was to determine the time to, and risk factors for, triple-class virological failure (TCVF) across age groups for children and adolescents with perinatally acquired HIV infection and older adolescents and adults with heterosexually acquired HIV infection.
Methods: We analysed individual patient data from cohorts in the Collaboration of Observational HIV Epidemiological Research Europe (COHERE). A total of 5972 participants starting antiretroviral therapy (ART) from 1998, aged < 20 years at the start of ART for those with perinatal infection and 15–29 years for those with heterosexual infection, with ART containing at least two nucleoside reverse transcriptase inhibitors (NRTIs) and a nonnucleoside reverse transcriptase inhibitor (NNRTI) or a boosted protease inhibitor (bPI), were followed from ART initiation until the most recent viral load (VL) measurement. Virological failure of a drug was defined as VL > 500 HIV-1 RNA copies/mL despite ≥ 4 months of use. TCVF was defined as cumulative failure of two NRTIs, an NNRTI and a bPI.
Results: The median number of weeks between diagnosis and the start of ART was higher in participants with perinatal HIV infection compared with participants with heterosexually acquired HIV infection overall [17 (interquartile range (IQR) 4–111) vs. 8 (IQR 2–38) weeks, respectively], and highest in perinatally infected participants aged 10–14 years [49 (IQR 9–267) weeks]. The cumulative proportion with TCVF 5 years after starting ART was 9.6% [95% confidence interval (CI) 7.0−12.3%] in participants with perinatally acquired infection and 4.7% (95% CI 3.9−5.5%) in participants with heterosexually acquired infection, and highest in perinatally infected participants aged 10–14 years when starting ART (27.7%; 95% CI 13.2−42.1%). Across all participants, significant predictors of TCVF were those with perinatal HIV aged 10–14 years, African origin, pre-ART AIDS, NNRTI-based initial regimens, higher pre-ART viral load and lower pre-ART CD4.
Conclusions: The results suggest a beneficial effect of starting ART before adolescence, and starting young people on boosted PIs, to maximize treatment response during this transitional stage of development.