Refine
Document Type
- Article (3)
Language
- English (3)
Has Fulltext
- yes (3)
Is part of the Bibliography
- no (3)
Institute
- Medizin (3)
Uncalibrated semi-invasive continous monitoring of cardiac index (CI) has recently gained increasing interest. The aim of the present study was to compare the accuracy of CI determination based on arterial waveform analysis with transpulmonary thermodilution. Fifty patients scheduled for elective coronary surgery were studied after induction of anaesthesia and before and after cardiopulmonary bypass (CPB), respectively. Each patient was monitored with a central venous line, the PiCCO system, and the FloTrac/Vigileo-system. Measurements included CI derived by transpulmonary thermodilution and uncalibrated semi-invasive pulse contour analysis. Percentage changes of CI were calculated. There was a moderate, but significant correlation between pulse contour CI and thermodilution CI both before (r(2) = 0.72, P < 0.0001) and after (r(2) = 0.62, P < 0.0001) CPB, with a percentage error of 31% and 25%, respectively. Changes in pulse contour CI showed a significant correlation with changes in thermodilution CI both before (r(2) = 0.52, P < 0.0001) and after (r(2) = 0.67, P < 0.0001) CPB. Our findings demonstrated that uncalibrated semi-invasive monitoring system was able to reliably measure CI compared with transpulmonary thermodilution in patients undergoing elective coronary surgery. Furthermore, the semi-invasive monitoring device was able to track haemodynamic changes and trends.
Background: The ability of stroke volume variation (SVV), pulse pressure variation (PPV) and global end-diastolic volume (GEDV) for prediction of fluid responsiveness in presence of pleural effusion is unknown. The aim of the present study was to challenge the ability of SVV, PPV and GEDV to predict fluid responsiveness in a porcine model with pleural effusions.
Methods: Pigs were studied at baseline and after fluid loading with 8 ml kg−1 6% hydroxyethyl starch. After withdrawal of 8 ml kg−1 blood and induction of pleural effusion up to 50 ml kg−1 on either side, measurements at baseline and after fluid loading were repeated. Cardiac output, stroke volume, central venous pressure (CVP) and pulmonary occlusion pressure (PAOP) were obtained by pulmonary thermodilution, whereas GEDV was determined by transpulmonary thermodilution. SVV and PPV were monitored continuously by pulse contour analysis.
Results: Pleural effusion was associated with significant changes in lung compliance, peak airway pressure and stroke volume in both responders and non-responders. At baseline, SVV, PPV and GEDV reliably predicted fluid responsiveness (area under the curve 0.85 (p<0.001), 0.88 (p<0.001), 0.77 (p = 0.007). After induction of pleural effusion the ability of SVV, PPV and GEDV to predict fluid responsiveness was well preserved and also PAOP was predictive. Threshold values for SVV and PPV increased in presence of pleural effusion.
Conclusions: In this porcine model, bilateral pleural effusion did not affect the ability of SVV, PPV and GEDV to predict fluid responsiveness.
Background: Remote ischemic preconditioning (RIPC) has been shown to enhance the tolerance of remote organs to cope with a subsequent ischemic event. We hypothesized that RIPC reduces postoperative neurocognitive dysfunction (POCD) in patients undergoing complex cardiac surgery.
Methods: We conducted a prospective, randomized, double-blind, controlled trial including 180 adult patients undergoing elective cardiac surgery with cardiopulmonary bypass. Patients were randomized either to RIPC or to control group. Primary endpoint was postoperative neurocognitive dysfunction 5–7 days after surgery assessed by a comprehensive test battery. Cognitive change was assumed if the preoperative to postoperative difference in 2 or more tasks assessing different cognitive domains exceeded more than one SD (1 SD criterion) or if the combined Z score was 1.96 or greater (Z score criterion).
Results: According to 1 SD criterion, 52% of control and 46% of RIPC patients had cognitive deterioration 5–7 days after surgery (p = 0.753). The summarized Z score showed a trend to more cognitive decline in the control group (2.16±5.30) compared to the RIPC group (1.14±4.02; p = 0.228). Three months after surgery, incidence and severity of neurocognitive dysfunction did not differ between control and RIPC. RIPC tended to decrease postoperative troponin T release at both 12 hours [0.60 (0.19–1.94) µg/L vs. 0.48 (0.07–1.84) µg/L] and 24 hours after surgery [0.36 (0.14–1.89) µg/L vs. 0.26 (0.07–0.90) µg/L].
Conclusions: We failed to demonstrate efficacy of a RIPC protocol with respect to incidence and severity of POCD and secondary outcome variables in patients undergoing a wide range of cardiac surgery. Therefore, definitive large-scale multicenter trials are needed.
Trial Registration: ClinicalTrials.gov NCT00877305