Refine
Document Type
- Article (4)
Language
- English (4)
Has Fulltext
- yes (4)
Is part of the Bibliography
- no (4)
Keywords
- Feasibility (1)
- Hip revision (1)
- Intraoperative procedure (1)
- MUTARS® RS cup system (1)
- SSTI (1)
- acute infections (1)
- adverse events (1)
- animal model (1)
- bundle (1)
- chronic infections (1)
Institute
- Medizin (4)
Background: Surgical complications are associated with a significant burden to patients and hospitals and are increasingly discussed in recent literature. This cohort study reviewed surgery-related complications in a Level I trauma center. The effect of a complication avoidance care bundle on the rate of surgical complications was analyzed. Methods: All complications (surgical and nonsurgical) that occur in our trauma department are prospectively captured using a standardized documentation form and are discussed and analyzed in a weekly trauma Morbidity and Mortality (M&M) conference. Surgical complication rates are calculated using the annual surgical procedure numbers. Based on discussions in the M&M conference, a complication avoidance care bundle consisting of five measures was established: (1) Improving team situational awareness; (2) reducing operating room traffic by staff members and limiting door-opening events; (3) preoperative screening for infectious foci; (4) adapted preoperative antibiotic prophylaxis in anatomic regions with a high risk of infectious complications; and (5) use of iodine-impregnated adhesive drape. Results: The number of surgical procedures steadily increased over the study years, from 3587 in 2015 to 3962 in 2019 (an increase of 10.5%). Within this 5-year study period, the overall rate of surgical complications was 0.8%. Surgical site infections were the most frequently found complications (n = 40, 24.8% of all surgical complications), followed by screw malposition (n = 20, 12.4%), postoperative dislocations of arthroplasties (n = 18, 11.2%), and suboptimal fracture reduction (n = 18, 11.2%). Following implementation of the complication avoidance care bundle, the overall rate of surgical complications significantly decreased, from 1.14% in the year 2016 to 0.56% in the study year 2019, which represents a reduction of 51% within a 3-year time period. Conclusions: A multimodal strategy targeted at reducing the surgical complication rate can be successfully established based on a transparent discussion of adverse surgical outcomes. The combination of the different preventive measures was associated with reducing the overall complication rate by half within a 3-year time period.
In Bone Tissue Engineering (BTE), autologous bone-regenerative cells are combined with a scaffold for large bone defect treatment (LBDT). Microporous, polylactic acid (PLA) scaffolds showed good healing results in small animals. However, transfer to large animal models is not easily achieved simply by upscaling the design. Increasing diffusion distances have a negative impact on cell survival and nutrition supply, leading to cell death and ultimately implant failure. Here, a novel scaffold architecture was designed to meet all requirements for an advanced bone substitute. Biofunctional, porous subunits in a load-bearing, compression-resistant frame structure characterize this approach. An open, macro- and microporous internal architecture (100 µm–2 mm pores) optimizes conditions for oxygen and nutrient supply to the implant’s inner areas by diffusion. A prototype was 3D-printed applying Fused Filament Fabrication using PLA. After incubation with Saos-2 (Sarcoma osteogenic) cells for 14 days, cell morphology, cell distribution, cell survival (fluorescence microscopy and LDH-based cytotoxicity assay), metabolic activity (MTT test), and osteogenic gene expression were determined. The adherent cells showed colonization properties, proliferation potential, and osteogenic differentiation. The innovative design, with its porous structure, is a promising matrix for cell settlement and proliferation. The modular design allows easy upscaling and offers a solution for LBDT.
Introduction: The aim of this article is to show a new concept of indication and application of the MUTARS® RS Cup System in primary and revision hip arthroplasty. This integrated system is applicable for different acetabular cup replacements in patients with acetabular fractures or instable defects, as well as periprosthetic acetabular fractures. The MUTARS® RS Cup System is a cementless revision cup for insertion into the acetabulum with an integrated polyethylene cup, which fits to a regular or bipolar head. This system replaces the conventional approach for acetabular revision with a Burch-Schneider ring, in which a normal polyethylene cup is cemented. This interface with its complications is avoided with this system of a titanium revision cup with integrated polyethylene cup. Steps of preoperative planning and the intraoperative implementation will be highlighted in this article.
Material and methods: This system was applied in 49 patients with 52 MUTARS® RS Cup Implantations in 30 males, 22 females, with an average age of 76,1 years (36,9–94,4 years).
Results and discussion: The system shows a good operative feasibility, as well as a reliable handling and safe method for stable treatment of non-reconstructable acetabular fractures or acetabular incongruencies and instabilities.
Objective: Skin and soft tissue infections (SSTI) are a commonly known entity of diseases associated with difficult treatment procedures. The current gold standard when there is a rapidly progressing infection of soft tissues with a risk of sepsis is radical surgical debridement accompanied by systemic antibiotic therapy. In clinical settings, local antibiotics alone or formulated within carrier material are commonly used alongside this therapy regimen. One possibility of local antibiotic application is the fixation of colistin with fibrin glue spray. It is not yet sufficiently researched how the local antibiotic concentrations remain as high as possible over time.
Methods: We conducted an animal study including 29 male Wistar rats inducing sterile back sores reaching the muscle fascia. We sprayed only colistin, simultaneously or consecutively, with fibrin glue in different groups in order to measure the tissue concentration of the antibiotic applied locally.
Results: After liquid chromatography and quadrupole mass spectrometry analysis, it could be demonstrated that in comparison to the colistin group, tissue concentrations of colistin stayed significantly higher in the wound tissue when it was fixed with fibrin glue. This was observed in both groups, the simultaneous as well as in the consecutively fibrin glue sprayed groups after colistin application.
Conclusion: The fixation of colistin with the fibrin-glue-spray technique as a carrier for local antibiotic therapy is an easy and inexpensive method and shows promising potential for the treatment of SSTI.