Refine
Year of publication
Document Type
- Article (49)
- Conference Proceeding (1)
Language
- English (46)
- German (3)
- Multiple languages (1)
Has Fulltext
- yes (50) (remove)
Is part of the Bibliography
- no (50)
Keywords
- 3D printing (3)
- 3D rapid prototyping (3)
- simulation training (3)
- Complication management (2)
- Dental students (2)
- Disintegration (2)
- Fistula (2)
- Flaps (2)
- Grafts (2)
- High oblique sagittal osteotomy (2)
Institute
- Medizin (50)
- Präsidium (2)
- Psychologie (2)
- Starker Start ins Studium: Qualitätspakt Lehre (2)
- Biowissenschaften (1)
Objective: The aim of this study was to retrospectively review the midface and orbital floor fractures treated at our institution with regard to epidemiological aspects, surgical treatment options and postoperative complications and discuss this data with the current literature. Study design: One thousand five hundred and ninety-four patients with midface and orbital fractures treated at the Department of Oral, Cranio-Maxillofacial and Facial Plastic Surgery of the Goethe University Hospital in Frankfurt (Germany) between 2007 and 2017 were retrospectively reviewed. The patients were evaluated by age, gender, etiology, fracture pattern, defect size, surgical treatment and complications. Results: The average patient age was 46.2 (± 20.8). Most fractures (37.5%) occurred in the age between 16 and 35. Seventy-two percent of patients were male while 28% were female. The most common cause of injury was physical assault (32.0%) followed by falls (30.8%) and traffic accidents (17.0%). The average orbital wall defect size was 297.9 mm2 (± 190.8 mm2). For orbital floor reconstruction polydioxanone sheets (0.15 mm 38.3%, 0.25 mm 36.2%, 0.5 mm 2.8%) were mainly used, followed by titanium meshes (11.5%). Reconstructions with the 0.15 mm polydioxanone sheets showed the least complications (p < 0.01, r = 0.15). Eighteen percent of patients who showed persistent symptoms and post-operative complications: 12.9% suffered from persistent hypoesthesia, 4.4% suffered from post-operative diplopia and 3.9% showed intra-orbital hematoma. Conclusion: Results of the clinical outcome in our patients show that 0.15 mm resorbable polydioxanone sheets leads to significantly less post-operative complications for orbital floor defects even for defects beyond the recommended 200 mm2.
Background: The high-oblique sagittal osteotomy (HOSO) is an alternative to a bilateral sagittal split osteotomy (BSSO). Due to its novelty, there are no long-term studies which have focused on describing the incidence and type of complications encountered in the post-operative follow-up. The aim of this retrospective study is to analyze patients operated on with this surgical technique and the post-operative complications encountered. Patient and methods: The electronic medical records of all patients treated with orthognathic surgery at the Department of Oral, Maxillofacial and Facial Plastic Surgery, University Hospital Frankfurt, Goethe University, Frankfurt, Germany, between the years 2009 and 2016 were retrospectively reviewed. Results: A total of 116 patients fulfilled the inclusion criteria. The cases operated on with the standard osteosynthesis (X, Y, and straight) showed a complication rate of 36.37% (n = 4/11). The cases operated on with the HOSO-dedicated plates (HOSO-DP) showed, in total, a complication rate of 6.67% (n = 7/105). The most common post-operative complication resulting from both fixation methods was a reduction in mouth opening and TMJ pain for 4.3%. During the first years of performing the surgery (2009–211), a variety of standard plates had material failure causing non-union or pseudarthrosis. No cases of material failure were observed in the cases operated on with the HOSO-DP. The statistical results showed a highly significant dependence of a reduction in OP-time over the years, when the HOSO was performed without additional procedures (R2 > 0.83, P < 0.0015). Conclusion: The rate of complications in the HOSO were shown to be comparable to the rate of complications from the BSSO reported in the literature. Moreover, the use of the ramus dedicated plate appears to provide enough stability to the bone segments, making the surgery safer. Clinical relevance: The HOSO needs to be considered by surgeons as an alternative to BSSO. Once the use of the HOSO-DP was established, the rate of complications and the operation time reduced considerably.
Background: The present study aimed to assess the three‐dimensional changes following soft tissue augmentation using free gingival grafts (FGG) at implant sites over a 3‐month follow‐up period.
Methods: This study included 12 patients exhibiting deficient keratinized tissue (KT) width (i.e., <2 mm) at the vestibular aspect of 19 implants who underwent soft tissue augmentation using FGG at second stage surgery following implant placement. Twelve implants were considered for the statistical analysis (n = 12). The region of interest (ROI) was intraorally scanned before surgery (S0), immediately post‐surgery (S1), 30 (S2) and 90 (S3) days after augmentation. Digital scanned files were used for quantification of FGG surface area (SA) and converted to standard tessellation language (STL) format for superimposition and evaluation of thickness changes between the corresponding time points. FGG shrinkage (%) in terms of SA and thickness was calculated between the assessed time points.
Results: Mean FGG SA amounted to 91 (95% CI: 63 to 119), 76.2 (95% CI: 45 to 106), and 61.3 (95% CI: 41 to 81) mm2 at S1, S2, and S3, respectively. Mean FGG SA shrinkage rate was 16.3% (95% CI: 3 to 29) from S1 to S2 and 33% (95% CI: 19 to 46) from S1 to S3. Mean thickness gain from baseline (S0) to S1, S2, and S3 was 1.31 (95% CI: 1.2 to 1.4), 0.82 (95% CI: 0.5 to 1.12), and 0.37 (0.21 to 0.5) mm, respectively. FGG thickness shrinkage was of 38% (95% CI: 17.6 to 58) from S1 to S2 and 71.8% (95% CI: 60 to 84) from S1 to S3. Dimensional changes from S1 to S3 were statistically significant, P <0.017. Soft tissue healing was uneventful in all patients.
Conclusions: The present three‐dimensional assessment suggests that FGG undergo significant dimensional changes in SA and thickness over a 3‐month healing period.
Background: Recent advances in 3D printing technology have enabled the emergence of new educational and clinical tools for medical professionals. This study provides an exemplary description of the fabrication of 3D‐printed individualised patient models and assesses their educational value compared to cadaveric models in oral and maxillofacial surgery.
Methods: A single‐stage, controlled cohort study was conducted within the context of a curricular course. A patient's CT scan was segmented into a stereolithographic model and then printed using a fused filament 3D printer. These individualised patient models were implemented and compared against cadaveric models in a curricular oral surgery hands‐on course. Students evaluated both models using a validated questionnaire. Additionally, a cost analysis for both models was carried out. P‐values were calculated using the Mann‐Whitney U test.
Results: Thirty‐eight fourth‐year dental students participated in the study. Overall, significant differences between the two models were found in the student assessment. Whilst the cadaveric models achieved better results in the haptic feedback of the soft tissue, the 3D‐printed individualised patient models were regarded significantly more realistic with regard to the anatomical correctness, the degree of freedom of movement and the operative simulation. At 3.46 € (compared to 6.51 €), the 3D‐printed patient individualised models were exceptionally cost‐efficient.
Conclusions: 3D‐printed patient individualised models presented a realistic alternative to cadaveric models in the undergraduate training of operational skills in oral and maxillofacial surgery. Whilst the 3D‐printed individualised patient models received positive feedback from students, some aspects of the model leave room for improvement.
After removal of a dental implant or extraction of a tooth in the upper jaw, the closure of an oroantral fistula (OAF) or oroantral communication (OAC) can be a difficult problem confronting the dentist and surgeon working in the oral and maxillofacial region. Oroantral communication (OAC) acts as a pathological pathway for bacteria and can cause infection of the antrum, which further obstructs the healing process as it is an unnatural communication between the oral cavity and the maxillary sinus. There are different ways to perform the surgical closure of the OAC. The decision-making in closure of oroantral communication and fistula is influenced by many factors. Consequently, it requires a combination of knowledge, experience, and information gathering. Previous narrative research has focused on assessments and comparisons of various surgical techniques for the closure of OAC/OAF. Thus, the decision-making process has not yet been described comprehensively.
The present study aims to illustrate all the factors that have to be considered in the management of OACs and OAFs that determine optimal treatment.
Background and Objective: Macrophages’ cytokine expression and polarization play a substantial role in the host's “destructive” inflammatory response to periodontal and peri‐implant pathogens. This study aimed to evaluate cell viability, anti‐inflammatory activity, and macrophage polarization properties of different cranberry concentrates.
Methods: THP‐1 cells (monocytic line) were treated with phorbol myristic acid to induce macrophage differentiation. Human gingival fibroblasts (HFIB‐G cell line), osteosarcoma‐derived osteoblasts (SAOS‐2 cell line), and induced macrophages were treated with cranberry concentrates at 25, 50, and 100 µg/mL for 120 seconds, 1 hour and 24 hours. Untreated cells at the same time points served as controls. For anti‐inflammatory analysis, induced macrophages exposed to cranberry concentrates (A‐type PACs) were stimulated with lipopolysaccharides (LPS) derived from E coli for 24 hours. Cell viability, interleukin (IL)‐8, IL‐1 ß, IL‐6, and IL‐10 expression of LPS‐stimulated macrophages, and macrophage polarization markers were evaluated through determination of live‐cell protease activity, enzyme‐linked immunosorbent assay, and immunofluorescence staining semi‐quantification.
Results: Cranberry concentrates (A‐type PACs) did not reduce HGF, SAOS‐2, and macrophage viability after 24 hours of exposure. Pro‐inflammatory cytokine expression (ie IL‐8 and IL‐6) was downregulated in LPS‐stimulated macrophages by cranberry concentrates at 50 and 100 µg/mL. Anti‐inflammatory IL‐10 expression was significantly upregulated in LPS‐stimulated macrophages by cranberry concentrates at 100 µg/mL after 24 hours of exposure. M1 polarization significantly decreased when LPS‐stimulated macrophages were exposed to cranberry concentrates. High levels of positive M1 macrophages were present in all untreated control groups. M2 polarization significantly increased at all LPS‐stimulated macrophages exposed to cranberry concentrates for 1 and 24 hours.
Conclusion: Cranberry‐derived proanthocyanidins may have the potential to act as an anti‐inflammatory component in the therapy of periodontal and peri‐implant diseases.
The prevalence of peri-implant diseases around subcrestally placed implants: a cross-sectional study
(2021)
Objectives: To evaluate the prevalence of peri-implant health, peri-implant mucositis or periimplantitis for subcrestally placed implants (1–3 mm) on the short-, medium- and long term.
Material and Methods: Two hundred patients were enrolled in this cross-sectional study that were treated and screened during regular maintenance visits at one university center. A total of 657 implants were evaluated. Peri-implant health and diseases were assessed according to predefined case definitions. Binary logistic regression was used to assess the correlation with local and systemic factors.
Results: After a median function time of 9.36 ± 6.44 years (range: 1–26 years), the prevalence of peri-implant mucositis and peri-implantitis was 66.5% and 15.0%, at the patient level, corresponding to 62.6% and 7.5%, at the implant level, respectively. Peri-implantitis was significantly associated with patients’ history of periodontitis (odds ratio, OR 5.33).
Conclusion: Peri-implant diseases were a common finding around subcrestally placed implants.
Purpose: To retrospectively compare the high-angled sagittal split osteotomy (HOO) and the bilateral sagittal split osteotomy (BSSO) for the correction of skeletal dysgnathias regarding intra- and postoperative complications.
Methods: The electronic medical records of all patients treated with an orthognathic surgery at the Department for Oral, Maxillofacial and Facial Plastic Surgery, University Hospital Frankfurt, Germany, between the years 2009 and 2019 were retrospectively reviewed.
Results: Two hundred ninety-one patients were included. The overall complication rates were 19.78% (BSSO) compared to 12.5% (HOO) (p = 0.14). Significant differences were found regarding the operation time (HOO < BSSO, p = 0.02), material failure (HOO > BSSO, p = 0.04), and early recurrence requiring revision surgery (HOO < BSSO, p = 0.002). The use of a ramus plate significantly reduced the risk of plate failure (2.8% < 13.6%, p = 0.05). More bad splits (p = 0.08) and early sensory disorders (p = 0.07) occurred in the BSSO group.
Conclusion: The HOO presents a possible alternative to the BSSO since newly developed osteosynthesis material significantly reduces the risk of material failure. The BSSO is accompanied by higher risks of developing complications like a bad split and sensory disorders but, however, remains the standard for large anterior–posterior transpositions of the mandible.
Objectives: A conometric concept was recently introduced in which conical implant abutments hold the matching crown copings by friction alone, eliminating the need for cement or screws. The aim of this in vitro study was to assess the presence of microgap formation and bacterial leakage at the Acuris conometric restorative interface of three different implant abutment systems. Material and methods: A total of 75 Acuris samples of three implant-abutment systems (Ankylos, Astra Tech EV, Xive) were subjected to microbiological (n = 60) and scanning electron microscopic (SEM) investigation (n = 15). Bacterial migration into and out of the conical coupling system were analyzed in an anaerobic workstation for 48, 96, 144, and 192 h. Bacterial DNA quantification using qrt-PCR was performed at each time point. The precision of the conometric coupling and internal fit of cemented CAD/CAM crowns on corresponding Acuris TiN copings were determined by means of SEM. Results: qrt-PCR results failed to demonstrate microbial leakage from or into the Acuris system. SEM analysis revealed minute punctate microgaps at the apical aspect of the conometric junction (2.04 to 2.64 µm), while mean cement gaps of 12 to 145 µm were observed at the crown-coping interface. Conclusions: The prosthetic morse taper connection of all systems examined does not allow bacterial passage. Marginal integrity and internal luting gap between the ceramic crown and the coping remained within the clinically acceptable limits. Clinical relevance: Conometrically seated single crowns provide sufficient sealing efficiency, relocating potential misfits from the crown-abutment interface to the crown-coping interface.