Resorbable synthetic scaffolds are promising for different indications, espe- cially in the context of bone regeneration. However, they require additional biological components to enhance their osteogenic potential. In addition to different cell types, autologous blood-derived matrices offer many advantages to enhance the regenerative capacity of biomaterials. The present study aimed to analyze whether biologization of a PCL-mesh coated using differently centrifuged Platelet rich fibrin (PRF) matrices will have a positive influence on primary human osteoblasts activity in vitro. A polymeric resorbable scaffold (Osteomesh, OsteoporeTM (OP), Singapore) was combined with differently centrifuged PRF matrices to evaluate the additional influence of this biologization concept on bone regeneration in vitro. Peripheral blood of three healthy donors was used to gain PRF matrices centrifuged either at High (710× g, 8 min) or Low (44× g, 8 min) relative centrifugal force (RCF) according to the low speed centrifugation concept (LSCC). OP-PRF constructs were cultured with pOBs. POBs cultured on the uncoated OP served as a control. After three and seven days of cultivation, cell culture supernatants were collected to analyze the pOBs activity by determining the concentrations of VEGF, TGF-β1, PDGF, OPG, IL-8, and ALP- activity. Immunofluorescence staining was used to evaluate the Osteopontin expression of pOBs. After three days, the group of OP+PRFLow+pOBs showed significantly higher expression of IL-8, TGF-ß1, PDGF, and VEGF compared to the group of OP+PRFHigh+pOBs and OP+pOBs. Similar results were observed on day 7. Moreover, OP+PRFLow+pOBs exhibited significantly higher activity of ALP compared to OP+PRFHigh+pOBs and OP+pOBs. Immunofluorescence staining showed a higher number of pOBs adherent to OP+PRFLow+pOBs compared to the groups OP+PRFHigh+pOBs and OP+pOBs. To the best of our knowledge, this study is the first to investigate the osteoblasts activity when cultured on a PRF-coated PCL-mesh in vitro. The presented results suggest that PRFLow centrifuged according to LSCC exhibits autologous blood cells and growth factors, seem to have a significant effect on osteogenesis. Thereby, the combination of OP with PRFLow showed promising results to support bone regeneration. Further in vivo studies are required to verify the results and carry out potential results for clinical translation.
Multinucleated giant cells (MNGCs) are frequently observed in the implantation areas of different biomaterials. The main aim of the present study was to analyze the long-term polarization pattern of the pro- and anti-inflammatory phenotypes of macrophages and MNGCs for 180 days to better understand their role in the success or failure of biomaterials. For this purpose, silk fibroin (SF) was implanted in a subcutaneous implantation model of Wistar rats as a model for biomaterial-induced MNGCs. A sham operation was used as a control for physiological wound healing. The expression of different inflammatory markers (proinflammatory M1: CCR-7, iNos; anti-inflammatory M2: CD-206, CD-163) and tartrate-resistant acid phosphatase (TRAP) and CD-68 were identified using immunohistochemical staining. The results showed significantly higher numbers of macrophages and MNGCs within the implantation bed of SF-expressed M1 markers, compared to M2 markers. Interestingly, the expression of proinflammatory markers was sustained over the long observation period of 180 days. By contrast, the control group showed a peak of M1 macrophages only on day 3. Thereafter, the inflammatory pattern shifted to M2 macrophages. No MNGCs were observed in the control group. To the best of our knowledge, this is study is the first to outline the persistence of pro-inflammatory MNGCs within the implantation bed of SF and to describe their long-term kinetics over 180 days. Clinically, these results are highly relevant to understand the role of biomaterial-induced MNGCs in the long term. These findings suggest that tailored physicochemical properties may be a key to avoiding extensive inflammatory reactions and achieving clinical success. Therefore, further research is needed to elucidate the correlation between proinflammatory MNGCs and the physicochemical characteristics of the implanted biomaterial.
Objective: The aim of this study was to retrospectively review the midface and orbital floor fractures treated at our institution with regard to epidemiological aspects, surgical treatment options and postoperative complications and discuss this data with the current literature. Study design: One thousand five hundred and ninety-four patients with midface and orbital fractures treated at the Department of Oral, Cranio-Maxillofacial and Facial Plastic Surgery of the Goethe University Hospital in Frankfurt (Germany) between 2007 and 2017 were retrospectively reviewed. The patients were evaluated by age, gender, etiology, fracture pattern, defect size, surgical treatment and complications. Results: The average patient age was 46.2 (± 20.8). Most fractures (37.5%) occurred in the age between 16 and 35. Seventy-two percent of patients were male while 28% were female. The most common cause of injury was physical assault (32.0%) followed by falls (30.8%) and traffic accidents (17.0%). The average orbital wall defect size was 297.9 mm2 (± 190.8 mm2). For orbital floor reconstruction polydioxanone sheets (0.15 mm 38.3%, 0.25 mm 36.2%, 0.5 mm 2.8%) were mainly used, followed by titanium meshes (11.5%). Reconstructions with the 0.15 mm polydioxanone sheets showed the least complications (p < 0.01, r = 0.15). Eighteen percent of patients who showed persistent symptoms and post-operative complications: 12.9% suffered from persistent hypoesthesia, 4.4% suffered from post-operative diplopia and 3.9% showed intra-orbital hematoma. Conclusion: Results of the clinical outcome in our patients show that 0.15 mm resorbable polydioxanone sheets leads to significantly less post-operative complications for orbital floor defects even for defects beyond the recommended 200 mm2.
Objectives: To evaluate peri-implant tissue dimensions following nonsurgical (NS) and surgical therapy (S) employing different decontamination protocols of advanced ligature-induced peri-implantitis in dogs.
Material & Methods: Peri-implantitis defects (n = 5 dogs, n = 30 implants) were randomly and equally allocated in a split-mouth design to NS or S treatment using either an Er:YAG laser (ERL), an ultrasonic device (VUS), or plastic curettes + local application of metronidazole gel (PCM), respectively. Horizontal bone thickness (hBT) and soft tissue thickness (hMT) were measured at different reference points: (v0) at the marginal portion of the peri-implant mucosa (PM); (v1) at 50% of the distance from PM to bone crest (BC); (v2) at the BC; (v3) at the most coronal extension of the bone-to-implant contact. Vertical peri-implant tissue height was calculated from PM to BC.
Results: All of the treatment groups showed a gradual hMT increase from v0 to the v2 reference point, followed by a reduction from v2 to the v3 region. The S-VUS subgroup tended to be associated with higher hMT values at the v0 region than the NS-VUS subgroup (0.44 mm versus 0.31 mm). PM-BC distance varied from 2.22 to 2.83 mm in the NS group, and from 2.07 to 2.38 in the S group.
Conclusion: Vertical and horizontal peri-implant tissue dimensions were similar in different treatment groups.
(1) Background: Protruding ears are the most common auricular malformation affecting approximately 5% of the population. One common factor leading to auricular protrusion is a deficiency or total absence of the antihelix. A technique first described by Gottfried Lemperle in 2003 attempts cartilage thinning, folding, and fixation by non-absorbable mattress sutures after ventral skin incision along the ventral helical rim. (2) Methods: Retrospective analysis of patient records was performed for otoplasties according to this technique, performed between 1985 and 2014 at Agaplesion Markus Hospital in Frankfurt, Germany. All recorded complications were examined. (3) Results: A total of 912 single otoplasties were performed according to this technique from 1985 to 2014. Overall complications included 26% minor complications not requiring further surgery and 11% major complications leading to revision surgery. Within those requiring revision surgery, the most common reason was recurrence of auricular protrusion (5%), followed by suture granulomas (5%) and hematomas (2%). (4) Conclusions: Lemperle’s otoplasty technique addresses the open thinning and shaping of the antihelix through a ventral incision along the helix to prevent irregularities and possible ridges. Results show a low complication rate comparable to data found in published studies. This technique is easy to perform, safe, and avoids often seen contour irregularities of the antihelix compared to techniques with a posterior approach.
The prevalence of peri-implant diseases around subcrestally placed implants: a cross-sectional study
(2021)
Objectives: To evaluate the prevalence of peri-implant health, peri-implant mucositis or periimplantitis for subcrestally placed implants (1–3 mm) on the short-, medium- and long term.
Material and Methods: Two hundred patients were enrolled in this cross-sectional study that were treated and screened during regular maintenance visits at one university center. A total of 657 implants were evaluated. Peri-implant health and diseases were assessed according to predefined case definitions. Binary logistic regression was used to assess the correlation with local and systemic factors.
Results: After a median function time of 9.36 ± 6.44 years (range: 1–26 years), the prevalence of peri-implant mucositis and peri-implantitis was 66.5% and 15.0%, at the patient level, corresponding to 62.6% and 7.5%, at the implant level, respectively. Peri-implantitis was significantly associated with patients’ history of periodontitis (odds ratio, OR 5.33).
Conclusion: Peri-implant diseases were a common finding around subcrestally placed implants.
Objectives: A conometric concept was recently introduced in which conical implant abutments hold the matching crown copings by friction alone, eliminating the need for cement or screws. The aim of this in vitro study was to assess the presence of microgap formation and bacterial leakage at the Acuris conometric restorative interface of three different implant abutment systems. Material and methods: A total of 75 Acuris samples of three implant-abutment systems (Ankylos, Astra Tech EV, Xive) were subjected to microbiological (n = 60) and scanning electron microscopic (SEM) investigation (n = 15). Bacterial migration into and out of the conical coupling system were analyzed in an anaerobic workstation for 48, 96, 144, and 192 h. Bacterial DNA quantification using qrt-PCR was performed at each time point. The precision of the conometric coupling and internal fit of cemented CAD/CAM crowns on corresponding Acuris TiN copings were determined by means of SEM. Results: qrt-PCR results failed to demonstrate microbial leakage from or into the Acuris system. SEM analysis revealed minute punctate microgaps at the apical aspect of the conometric junction (2.04 to 2.64 µm), while mean cement gaps of 12 to 145 µm were observed at the crown-coping interface. Conclusions: The prosthetic morse taper connection of all systems examined does not allow bacterial passage. Marginal integrity and internal luting gap between the ceramic crown and the coping remained within the clinically acceptable limits. Clinical relevance: Conometrically seated single crowns provide sufficient sealing efficiency, relocating potential misfits from the crown-abutment interface to the crown-coping interface.
Introduction: The treatment of carious lesions is one of the most fundamental competencies in daily dental practice. However, many commercially available training models lack in reality regarding the simulation of pathologies such as carious lesions. 3D printed models could provide a more realistic simulation. This study provides an exemplary description of the fabrication of 3D printed dental models with carious lesions and assesses their educational value compared to commercially available models in conservative dentistry.
Materials and Methods: A single-stage, controlled cohort study was conducted within the context of a curricular course. A stereolithographic model was obtained from an intraoral scan and then printed using fused deposition modelling. These models were first piloted by experts and then implemented and compared against commercial models in a conservative dentistry course. Experts and students evaluated both models using a validated questionnaire. Additionally, a cost analysis for both models was carried out.
Results: Thirteen dentists and twenty-seven 5th year dental students participated in the study. The 3D printed models were rated significantly more realistic in many test areas. In particular, the different tactility and the distinction in colour was rated positively in the 3D printed models. At 28.29€ (compared to 112.36€), the 3D printed models were exceptionally cost-efficient.
Conclusions: 3D printed dental models present a more realistic and cost-efficient alternative to commercial models in the undergraduate training of conservative dentistry.
Efficacy of platelet-rich fibrin in promoting the healing of extraction sockets: a systematic review
(2021)
Purpose: To address the focused question: in patients with freshly extracted teeth, what is the efficacy of platelet-rich fibrin (PRF) in the prevention of pain and the regeneration of soft tissue and bone compared to the respective control without PRF treatment?
Methods: After an electronic data search in PubMed database, the Web of Knowledge of Thomson Reuters and hand search in the relevant journals, a total of 20 randomized and/or controlled studies were included.
Results: 66.6% of the studies showed that PRF significantly reduced the postoperative pain, especially in the first 1–3 days after tooth extraction. Soft tissue healing was significantly improved in the group of PRF compared to the spontaneous wound healing after 1 week (75% of the evaluated studies). Dimensional bone loss was significantly lower in the PRF group compared to the spontaneous wound healing after 8–15 weeks but not after 6 months. Socket fill was in 85% of the studies significantly higher in the PRF group compared to the spontaneous wound healing.
Conclusions: Based on the analyzed studies, PRF is most effective in the early healing period of 2–3 months after tooth extraction. A longer healing period may not provide any benefits. The currently available data do not allow any statement regarding the long-term implant success in sockets treated with PRF or its combination with biomaterials. Due to the heterogeneity of the evaluated data no meta-analysis was performed.