Refine
Document Type
- Article (2)
Language
- English (2)
Has Fulltext
- yes (2)
Is part of the Bibliography
- no (2)
Keywords
Institute
- Medizin (2)
Radiographic outcomes following lateral alveolar ridge augmentation using autogenous tooth roots
(2018)
Background: To assess and compare the radiographic outcomes following lateral alveolar ridge augmentation using autogenous tooth roots (TR) and autogenous bone (AB) blocks.
Methods: In a total of 30 patients, lateral ridge augmentation was conducted in parallel groups using either (1) healthy autogenous tooth roots (e.g., retained wisdom or impacted teeth) (n = 15) or (2) cortical autogenous bone blocks harvested from the retromolar area. Cone-beam computed tomographic (CBCT) scans taken at 26 weeks of submerged healing were analyzed for the basal graft integration (i.e., contact between the graft and the host bone in %) (BI26) and the cross-sectional grafted area (mm2) (SA26).
Results: Both groups revealed a comparable clinical width of the alveolar ridge at baseline (CWb). Mean BI26 and SA26 values amounted to 69.26 ± 26.01% (median 72.44) and 22.07 ± 12.98 mm2 (median 18.83) in the TR group and 79.67 ± 15.66% (median 78.85) and 12.42 ± 10.11 mm2 (median 11.36) in the AB group, respectively. Between-group differences in mean SA26 values were statistically significant (p = 0.031). Linear regression analysis failed to reveal any significant correlations between BI26 and CWb/SA26 values in either group.
Conclusions: TR grafts may be associated with improved SA26 values following lateral alveolar ridge augmentation.
Trial registration: DRKS00009586. Registered 10 February 2016.
Objectives: To assess the short‐term clinical outcomes of lateral augmentation of deficient extraction sockets and two‐stage implant placement using autogenous tooth roots (TR).
Material and methods: A total of n = 13 patients (13 implants) were available for the analysis. At the time of tooth extraction, each subject had received lateral augmentation using the respective non‐retainable but non‐infected tooth root where the thickness of the buccal bone was <0.5 mm or where a buccal dehiscence‐type defect was present. Titanium implants were placed after a submerged healing period of 6 months and loaded after 20 ± 2 weeks (V8). Clinical parameters (e.g., bleeding on probing—BOP, probing pocket depth—PD, mucosal recession—MR, clinical attachment level—CAL) were recorded at V8 and after 26 ± 4 weeks (V9) of implant loading.
Results: At V9, all patients investigated revealed non‐significant changes in mean BOP (−19.23 ± 35.32%), PD (0.24 ± 0.49 mm), MR (0.0 ± 0.0 mm) and CAL (0.24 ± 0.49 mm) values, respectively. There was no significant correlation between the initial gain in ridge width and changes in BOP and PD values.
Conclusions: The surgical procedure was associated with stable peri‐implant tissues on the short‐term.